Post by bmatlove on Variable Length Array - Cannot mix variable and fixed length dimensions?
CODESYS Forge
talk
(Post)
Using Codesys 3.5.18.30 I am trying to work with an array of variable length in one dimension, but known in the other dimension. For example, using an array that represents a list of items, each with an attribute profile. I do not know how many items will be in the list, but I know that every item has 5 attributes, like size, weight, etc. Codesys does not seem to be able to accept this. I have referenced Data Type: ARRAY OF documentation page, which is not explicit if variable & fixed length array dimensions can be mixed. In the VAR_IN_OUT scope, I initially tried MY_ARRAY : ARRAY [*, *] OF REAL; which was no problem, of course. I then modified it to MY_ARRAY : ARRAY [*, 1..5] OF REAL; which throws C0006: ', or ]' expected instead of '..' among consequent downstream errors. I then used the Auto Declare -> Array Wizard, which accepted (asterisk)-(asterisk) and 1-5 for 2-dimensional lower and upper bounds. It output: MY_ARRAY: ARRAY[*..*, 1..6] OF INT; which throws the same error stream. What's the deal here? Is this possible?
Last updated: 2025-05-23
Post by astutoski on No Motion with SM3_RaspiStepper (GPIO 23/24 Show No Pulses)
CODESYS Forge
talk
(Post)
Hi everyone, I’m completely new to CODESYS and have been teaching myself. And i Want to control an Axis using SM3RaspiStepper. Following the example on the RaspiStepper home page, I set up an axis through a POU and tied the SMC_StartupDrive (Visu) template to my axis instance (sud). Unfortunately, the motor never moves and I don’t see any pulses on the PULSE pin (GPIO 23). Hardware -Raspberry Pi 4 B -Nema 17 stepper motor -A4988 stepper driver (EN pin permanently tied to GND) Software / Runtime -CODESYS 3.5 SP21 Patch 1 – Raspberry Pi runtime (demo) -SoftMotion in demo mode -Package: SM3_RaspiStepper 0.0.0.6 Axis parameters: Pulse pin GPIO 23 Direction pin GPIO 24 Enable pin 0 (unused) Disable pin 0 (unused) Whether I start the axis from the visualization template or through Online Config Mode, the motor never spins. In Online Config Mode I press Power → the state changes from Standstill to Discrete_Motion, but the motor shaft is still locked and no step pulses appear on GPIO 23 (checked with a scope). I can provide screenshots of the Visualization, PLC logs, or wiring pictures if that helps. Any ideas on what I might be missing? Happy to provide screenshots, project files, or scope captures if that helps. Thanks in advance!
Last updated: 2025-06-25
Post by iliyatsukerman on SoftMotion auf PFC200
CODESYS Forge
talk
(Post)
Hallo, Wir würden Ihre Unterstützung bei der Überprüfung der Kompatibilität der folgenden Konfiguration sehr schätzen: • PSTR-LO-16/400FEV ELMO • SCALANCE XC208 • WAGO PFC200 750-8213/40-010 • Die SPS (WAGO) wird gleichzeitig eingesetzt als: o EtherCAT-Master zur Kommunikation mit einem Elmo-Servoantrieb (EtherCAT-Slave, 4 Achsen – generisches CiA 402-Profil), und o Modbus-TCP-Server zur Kommunikation mit einem Siemens Modbus-TCP-Client, welcher zur Fernsteuerung des Elmo-Servoantriebs über die SPS dient. Bitte bestätigen Sie, ob die SPS in der Lage ist, diese Dualfunktion — als EtherCAT-Master und gleichzeitig als Modbus-TCP-Server — ohne Konflikte oder Performanceprobleme zu unterstützen. Insbesondere interessiert uns, ob die CODESYS SoftMotion SL Basislizenz (2305000000-F) notwendig ist, um 4 Servoachsen zu steuern, und ob diese Lizenz auf einer WAGO PFC200 SPS mit CODESYS Version 3.5 Service Pack 19 Patch 40 oder höher unterstützt wird. Alle Achsen im Servoantrieb werden unabhängig voneinander gesteuert. Mit freundlichen Grüßen. ILIYA
Last updated: 2025-07-13
Post by marsmaennchen on MQTT,mehrere Topics publish/subscribe
CODESYS Forge
talk
(Post)
Hallo zusammen, ich habe im Grunde dieselbe Frage wie in diesem Thread: https://forge.codesys.com/forge/talk/Deutsch/thread/85372a6daf/ Leider hat der Threadersteller das Problem selbst gelöst, ohne seine Lösung zu teilen. Mein Setup: Ich möchte von einer WAGO PFC200 Daten per MQTT an HomeAssistant übertragen. Die Grundkommunikation steht bereits. Angenommen, man hat 50 Lichtschalter und 50 Lampen. Wie ist das übliche Vorgehen, um 50 einzelne Bool-Werte (Lichtschalter ein/aus) effizient zu übertragen? Ich finde einfach kein Beispiel, das ich als Vorlage nutzen könnte. Muss wirklich für jeden Lichtschalter ein eigenes MQTT-Topic und somit ein eigener Baustein in CODESYS angelegt werden? Also z. B. Topic/LS1/state, Topic/LS2/state usw.? Oder gibt es eine gängige, professionellere Methode, mehrere Schalter effizient zu übertragen? Zur Eingrenzung: Ich nutze die CODESYS IIoT Libraries, da die Janz Tec MQTT Library für mich bisher zu komplex ist. Kann mir jemand bitte erklären, wie Profis so etwas lösen? Vielen Dank schon mal für eure Tipps! Gruß Patrick
Last updated: 2025-10-10
Post by giackanto on Eoe issues with Windows and Linux
CODESYS Forge
talk
(Post)
Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Control Technique. Despite following some online guides (https://content.helpme-codesys.com/en/libs/EtherCATStack/4.3.0.0/Ethernet_over_EtherCAT/fld-Ethernet_over_EtherCAT.html) I haven’t had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here is my configuration: On Debian: (See attachments 1, 2, 3) enp1s0 = Ethernet port enp2s0 = EtherCAT port tap2 = TAP device IP forwarding and routes are both configured. On Windows: (See attachments 4, 5) On Codesys: (See attachments 6, 7) Version: Windows 11 Debian GNU/Linux 11 Codesys 3.5.17 Control for Linux SL 4.7.0 EtherCAT 4.4.0 With this configuration, I can ping the TAP device, but not the drive (See attachment 8). Could someone explain how to properly configure all these settings? Thank you, GA
Last updated: 2023-12-19
Post by yannickasselin on Connect to remote PLC via local pc and teamviewer
CODESYS Forge
talk
(Post)
Yes it is possible. I did it a lot of times using TeamViewer VPN. Unfortunately, TeamViewer VPN only works on Windows. If the remote PLC is a Codesys runtime running on Windows, you should be able to login directly using TeamViewer VPN if it is installed on the PC/PLC. If it is not Windows based, you can still do it but you need to have a Windows based PC acting as a gateway in the middle. In this case you need to enable IP Forwarding on the Windows remote PC (the gateway) and you need to setup the gateway IP address on the PLC to be the address of the Windows PC. Then you need to add a route on your local PC to point to the gateway PC for Codesys communication. I know it may not be detailed enough but I did not want to make a whole tutorial on how to do it. Bottom line, it is possible. I do it all the time.
Last updated: 2024-02-02
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Ich habe einen brandneuen Beckhoff-Panel-PC mit einer Codesys Control Runtime V3 eingerichtet. Ich habe es zusammen mit 2 Profinet-Feldgeräten konfiguriert: einem 16in/16out IO-Modul von Turck und einem MTS-Linearencoder. Die Maschine funktioniert einwandfrei, bis plötzlich die Kommunikation abbricht und die Profinet-Teilnehmer nicht mehr erreichbar sind. Zu diesem Zeitpunkt kann ich das Gerät noch anpingen, aber der Profinet-Master findet sie nicht mehr: Wenn ich einen Scan durchführe, werden sie nicht gefunden. Wenn ich einen Kaltstart durchführe, wird der Profinet-Master wieder aktiv und die Geräte werden wieder gefunden. Im Protokoll erhalte ich den Ethercat-Paketempfangsfehler: sysethernet. Ich bin etwas verwirrt, es gibt kein Ethercat-Gerät im Gerätebaum. Ich habe den Sendetakt und das Untersetzungsverhältnis bereits auf höhere Werte eingestellt, jedoch ohne Ergebnis. Kann Codesys so konfiguriert werden, dass die Kommunikation ohne Kalt-Reset wiederhergestellt wird? Das ist sehr ärgerlich und verursacht viele Produktionsausfälle. Grüße Tim
Last updated: 2024-02-27
Post by squiggleypuff on RemoteTargetVisu creates Unresolved Reference
CODESYS Forge
talk
(Post)
I have a project with a Festo CPX-E-CEC-C1-PN PLC (Run-time version 3.5.12.50) that I have been developing on just fine using Codesys V3.5 SP19 Patch 5 (64bit). I am at the stage where I wanted to use the Festo HMI screen, and have added a RemoteTargetVisu object to my application. After adding this object, I am no longer able to log in to the PLC as I get an Unresolved Reference warning for 'USERMGRUSERGETPROPERTY' towards the end of the download process. I was able to find this post (https://forge.codesys.com/forge/talk/Visualization/thread/fc686a6cb2/) where the two possible solutions are to "set the placeholder to emtpy" or update the runtime. Problem is, I don't know how to do either of these things, as I'm still very green in Codesys land. I'd be happy to update the Festo PLC runtime, as that seems like the better option, but have not had any luck in finding a tutorial for this online. If anyone could point me in the right direction I'd appreciate it.
Last updated: 2024-03-19
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via CmpApp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by leafy on Use third party actuator with IO-Link Master (IFM)
CODESYS Forge
talk
(Post)
Hey there! I am currently doing a little automation project for uni. I am trying to integrate a control-valve-system (Buerkert AirLINE Field) in my IO-Link environment. With IFM sensors, I used their pre-built function blocks, but with this third-party device, i need to write my own function block. Thankfully, IFM provides a generic sensor-fb so I can write my own FB with "extends" and "super". So far, so good. I found the IODD and some other documentation and I thought I get how it works, but somehow can't really get it to work at all. From my understanding, i need to write data into the PDO-Array. But i get confused with the indices and subindices of IO-Link. I'll append the IODD and some screenshots of my project. There is an AOI for LogicXDesigner, but I can't use that in Codesys. I hope someone has integrated a IOL-device in Codesys before and can help me with this. Cheers leafy
Last updated: 2024-04-16
Post by leafy on Use third party actuator with IO-Link Master (IFM)
CODESYS Forge
talk
(Post)
Hey there! I am currently doing a little automation project for uni. I am trying to integrate a control-valve-system (Buerkert AirLINE Field) in my IO-Link environment. With IFM sensors, I used their pre-built function blocks, but with this third-party device, i need to write my own function block. Thankfully, IFM provides a generic sensor-fb so I can write my own FB with "extends" and "super". So far, so good. I found the IODD and some other documentation and I thought I get how it works, but somehow can't really get it to work at all. From my understanding, i need to write data into the PDO-Array. But i get confused with the indices and subindices of IO-Link. I'll append the IODD and some screenshots of my project. There is an AOI for LogicXDesigner, but I can't use that in Codesys. I hope someone has integrated a IOL-device in Codesys before and can help me with this. Cheers leafy
Last updated: 2024-04-16
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
The hole setup is made by 3s. So its a comination of one not two. If Epis decide not to support extra licence whats then the funtion of providing an option with a single license ?? So the idee by 3s has a flod. Epis change the system to add the Stick. I send controller inc stick to Epis. On my software i can see the stick. An then you tel me i need a other license to use an license ?? Makes completly no sense. Codesys should be flexible but is not. I tried Delta. But has no HMI and has its own Codesys ?? Why ?? Then i tried Crist. The block there own system by a password. But dont know the password and cant switch it off. At the end the want me to pay for support to solve ther own made problem. So i send it al back. The extra license is adviced by 3s . Now a few month later still no working solution.
Last updated: 2024-05-01
Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection)
CODESYS Forge
talk
(Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06
Post by william-blandon on RecipeManCommands.ReloadRecipes
CODESYS Forge
talk
(Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23
Post by hppatrick on Datenkonvertierung fĂĽr ein SPS-AO-Modul
CODESYS Forge
talk
(Post)
Hi Leute , ich bin neu hier im Forum und habe seit kurzer Zeit mein eigenes SPS-Projekt. Ich stoße hin und wieder an Probleme aber habe diese auf kurz oder lang gelöst. Nun zu meinem Problem: Als Projekt habe ich eine Kühlwassersteuerung , die einen Relativdruck einließst, und anhand desssen Werte dann einen Frequenzumrichter ansteuert. Z. Bsp. 5Bar -> FU auf 70Prozent. Ich lese in Codesys den Analogwert mit der Wago A20_750_455_020 ein. Dieser Wert wird umgerechnet mit LIN_TRAFO in 0-10 (Bar)und und wird dann über einen PID Regler geregelt. (Bibliothek UTIL). Dieser Wert wird dann wieder für die Ausgangskarte Umgerechnet (LIN_TRAFO) . Nun zu meinem Problem : Die Ausgangskarte nimmt nur einen Word Datentyp und meine Bausteine haben den REAL Datentyp. Wenn ich einen Konvertierungsbaustein nehme, Schmeist mir Codesys einen Fehler und das Programm wird geschlossen. Könnt Ihr mir helfen? Vielen Dank im Voraus (Datei habe ich angehängt). Die Ausgangskarte ist eine Wago 750-555-08
Last updated: 2024-06-14
Post by mp9876 on Problem using MeasureFrequence FB
CODESYS Forge
talk
(Post)
Hi everyone, new at Codesys and PLC programming in general. I am using Codesys Win V3.5 SP20 I would like to measure an encoder's frequency output (obtaining that pulse train from Factory IO) and intended to use the MeasureFrequence FB (Intern/CAA/Utilities/CAA Mathematics/3.5.19.0). As mentioned in the title what I need to measure is low frequency, such as lower than 40hz (a cycle every 25mS) or so; I could even go lower frequency if required as this is for test purposes) therefore I am not expecting problem measuring a low frequency with that FB The library in question appears to be installed as I can retrieve it from the Library Repository. I can also see it from the Device's Library Manager. Problem arises when I am trying to instantiate this particular FB. I go like this: VAR MeasF:MeasureFrequence; END_VAR Please note that as soon as I start typing the "MeasureFrequence", the MeasureFrequence comes out as a viable option in auto-typing; seems to indicate that the FB is recognized somehow. But there is no way I can compile this as it comes back with the following: C0046: Identifier 'MeasureFrequence' not defined. Tried to rename that to ABC instead of MeasF; same issue. Possibly that the library is not properly installed ? Placeholder ? I would greatly appreciate a bit of guidance if possible. Thank you and regards, Mike
Last updated: 2024-06-24
Post by cmj-icsys on Custom configure tab in device editor
CODESYS Forge
talk
(Post)
Hi everyone, I’m developing a custom CODESYS I/O driver for my company’s device, and I’ve been studying the example projects in CODESYS V3.5 SP20 Patch 5. In the IOMappingExample.project, I noticed that EtherCAT devices provide additional configuration tabs in the Device Editor, such as General, Process Data, etc. However, for custom I/O driver examples (based on IoDrv), the Device Editor only shows the default tabs like <devicename> I/O Mapping or <devicename> Parameters.</devicename></devicename> I’d like to create custom tabs or configuration pages in the Device Editor (e.g., “General Settings”, “Communication”, etc.) to allow users to configure parameters in a more structured way. Could anyone explain: How to define and register custom tabs or UI pages in the Device Editor? What tools or SDKs are needed to create UI elements such as combo boxes or check boxes? How to bind those UI controls to device parameters defined in the XML (device description)? Any example, SDK reference, or documentation link would be really helpful. Thanks in advance!
Last updated: 2025-10-20
Post by andrea199403 on Assigning Modbus addresses to a structure in a dynamic way
CODESYS Forge
talk
(Post)
Hello everyone, I am new to this forum and I am also new to Codesys programming. My problem is this: I have a STRUCT of 64 bool and 30 real, this STRUCT is assigned in the programme 9 times. Now I need to communicate with an HMI via Modbus and I have defined the slave device and created the holding registers for communication. I would like to declare the first call of the STRUCT on the Modbus registers %QX2000.0 to %QX2007.7 for the booleans and on the registers %QW1004 to %QW1034 for the real registers. That said, I would like to change an index and set an offset of 100 bytes for the calls of the other 8 assignments, so that the result is: %QX2100.0 to %QX2107.7 for the booleans and on the %QW1104 to %QW1134 registers for the Real registers, etc. Is there a way to declare this? Thank you very much.
Last updated: 2025-10-21
Post by mil581 on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0?
CODESYS Forge
talk
(Post)
Hello everyone! I'm facing a weird issue with CODESYS Control Win V3 x64 on a fresh Windows install. The situation is as follows: CODESYS Modbus TCP Server (Slave) is running and I can see live values in the mapping display of Modbus settings: GVL (e.g., 32, 42, 50). Port 502 is LISTENING according to netstat. When connecting via Modbus Poll or Node-RED, the connection status changes to ESTABLISHED and everything reports as fine. The Problem: Despite the successful connection, all holding registers return 0 no matter what. It's like the OS accepts the TCP handshake, the request counter goes up but the data payload never reaches Modbus Client (in this case Node-RED or Modbus Poll). Quick Stats: Firewall: Completely OFF. Unit ID: Verified & Matching. IP: Tried 127.0.0.1 and 192.168.0.1. Interface: Correctly bound in Ethernet Device settings. I already tried absolutely everything from changing IP address, subnet, port, deleting the project and starting new one and even nuking my old Windows install. Since I am near completion of my bachelor thesis only thing left for me to do is connect SoftPLC to NodeRED via Modbus but this issue is driving me crazy for weeks. I do not know what to do anymore.
Last updated: 2025-12-25
Post by nixola on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
Hi, I added the following lines to /etc/codesyscontrol/CODESYSControl_User.cfg: [CmpCharDevice] PermittedPath.0=/dev/i2c* PermittedPath.1=/dev/spidev* PermittedPath.2=/sys/class/gpio/* PermittedPath.3=/dev/gpiochip* However, I'm still unable to read or control GPIO pins from any CODESYS application. Specifically, setting the pin direction (and, thus, the IoDrvGpioSysfs driver configuration) fails, with a rather non-descript error in the logs: Description Component Setting direction failed for GPIO pin 586 IEC Update configuration failed from driver IoDrvGPIOSysfs CmpIoMgr I'm running CODESYS Control for Linux ARM64 SL version 4.21.0.0; it's running in rootless mode, as the codesyscontrol user, but said user is in the gpio group and can otherwise normally interact with GPIO, both via gpioset/gpioget and via the sysfs driver in /sys/class/gpio/. The system is a custom 64-bit Raspberry OS based distro, running on a Raspberry Pi CM5 on kernel 6.18.34 with PREEMPT_RT scheduling.
Last updated: 2026-07-21
Post by gseidel on Mismatch between coordinate monitor and actual motion using SMC_GroupJog2, MC_MoveLinearAbsolute (6DOF)
CODESYS Forge
talk
(Post)
Hi darwin01, looking at the video and comparing the movement with the first figure in https://content.helpme-codesys.com/en/libs/SM3_Transformation/Current/SM3_Transformation/Function-Blocks/Standalone-Kinematics/Articulated-Robots/6AxisArticulated/Kin_ArticulatedRobot_6DOF.html, I think that the direction of rotation does not match between the RoboDK model and the CODESYS 6DOF kinematics. In the CODESYS kinematics, A1 and A2, when moved in positive direction, rotate into the opposite direction to what the RoboDK model does. This could explain the strange movements. For real axes, you could change the direction using the "Invert direction" flag of the scaling/mapping page. For your simulation, you could manually invert the position of the axes A1 and A2 before sending them to RoboDK. (A0 seems correct, please also check A3, A4, and A5. The figure I mentioned gives the order of positive rotation with arrows through the joints. You can use the right-hand-rule to see what the positive rotation is.) Best regards, Georg
Last updated: 2026-10-12
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
Good morning, I'm digging into this topic because I'm curious about resolving my problem in a test environment. In my previous message, I asked about the CODESYS Safe Timeprovider SL package (4.18.0.0), which I saw in the illustration. I noticed that it runs as a service. I am asking about this because from the perspective of an "ordinary" user, this service provides easier access to the settings of the time provider's operating parameters. The basic time provider configuration is outlined at https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_virtual_safe_time_provider.html. Why my questions? They stem from my specific case, which is experiencing timeout issues. I know that my environment is currently only a test environment. I'm assuming a real-world scenario in which I won't be able to achieve a better result with my configuration, and I will ultimately need to increase the time provider's cycle time. By running the time provider service, I can easily influence the time provider's operation and thus eliminate the problem. I know, I know, safety systems are not life-enhancing extras.
Last updated: 2025-11-19
Post by animesh on SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP
CODESYS Forge
talk
(Post)
Hello everyone, I am facing a persistent issue with the OPC UA Server on Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) and need help from the community. Device Information Name: Advantech Control x86 RTE V3 x64 Vendor: Advantech Co., Ltd. Categories: PLCs Version: 3.5.20.10 Description: Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) Problem Summary The OPC UA Server works perfectly when accessed via: opc.tcp://localhost:4842 opc.tcp://<hostname>:4842</hostname> But it does NOT work when using the LAN IP: opc.tcp://192.168.0.XX:4842 In UAExpert I get: Discovery FindServers on opc.tcp://192.168.0.XX:4842 failed (BadCommunicationError) Port is LISTENING in windows Firewall.. Tried with turning off the firewall completely. System Information Windows 10 x64 Advantech CODESYS RTE Soft-PLC (hard real-time) Network IP: 192.168.0.XX Hostname: WINDOWS-XXXXX Need your Support
Last updated: 2025-11-24
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.