Post by tqvist on Gateway Start CODESYS Forge talk (Post)
Hello, I am trying to connect to my PLC (IFM CR711S) via VPN(EWON COSY). I have been told to use Gateway SP14 or higher. I installed CODESYS 3.5 SP20 Patch4. In the Codesys Installer Software I can sleect "Set Gateway Service" and I do so for CODESYS 3.5 SP20 Patch4. I can start the Gateyay and select About and it shows: "CoDeSys Gateway V3 - x64 Version 3.5.20.40" (see attached) For compatibility reasons I have to run my PLC code in 3.5 SP11 and when I start I can first connect but then somehow the system restarts an older version of the Gateway only displaying: "CoDeSys Gateway V3" (see attached) I guess my question is how to run an old Cocesys Software with a new Gateway?
Last updated: 2024-11-26

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
CODESYS runtime version 4.9.0.0 for your Pi. ssh user should be pi. This is for RasperrPi Os 32 bit. If you are on RasperryPi OS 64Bit use Arm 64bit SL product as Runtime.
Last updated: 2023-09-11

Post by voffi on CODESYS Custom Build Step CODESYS Forge talk (Post)
Good morning! Is there a way to run a python script or something else automatically after CODESYS (3.5) did its build or before download? I am searching for something like the Custom Build steps in Visual Studio. Thank you! Voffi
Last updated: 2023-12-07

Post by pavanifm on CODESYS 3.5 Testmanager and Jenkins CODESYS Forge talk (Post)
Hello All, we are also struggling with the same issue, can we start codesys test manager with CLI interface headless/ without UI? This is preventing us to do CI from git for our test automation.
Last updated: 2024-08-07

Post by i-campbell on Codesys 3.5 Library Download Failed CODESYS Forge talk (Post)
You use very old codesys, maybe SP13? the newer sp17 libraries are in a format not compatible with your version. I suggest upgrading everything to at least SP17, but may as well go to SP20 Patch 2.
Last updated: 2024-08-21

Post by c3po on Visualisierung wechseln ΓΌber SPS Variable Codesys 3.5 CODESYS Forge talk (Post)
kann das bitte noch mal jemand genauer beschreiben? Der Link funktioniert nicht, weil Codesys so schlau war seine Onlinehilfe abzuschalten. Das denen das nicht peinlich ist -.-
Last updated: 2024-08-26

Post by nielscho on Saving "Input/output names" in a DCF file CODESYS Forge talk (Post)
Hello i have the same question but for Codesys 3.5. alternativley, could somebody name a Programm to create a DCF file out of an EDS? best regards
Last updated: 2025-07-02

Post by meldawltly on Excel to Codesys 3.5 CODESYS Forge talk (Post)
Hello everyone, I have an excel file that i want to import into codesys3.5. Any idea how and what libraries can i use? To more clarify i have a table in codesys and i want to import my excel file into this table/ Thank you
Last updated: 2023-12-11

Post by meldawltly on Excel to Codesys 3.5 CODESYS Forge talk (Post)
Hello everyone, I have an excel file that i want to import into codesys3.5. Any idea how and what libraries can i use? To more clarify i have a table in codesys and i want to import my excel file into this table/ Thank you
Last updated: 2023-12-11

Post by yann2021 on SoftMotion: Error after generate code CODESYS Forge talk (Post)
Hello, I have a project who was working in a previous version of Codesys but if I open it now with Codesys 3.5 SP19 Patch2 I have errors after code generation. Who can me please help to solve these errors?
Last updated: 2024-01-30

Post by goki on WAGO RS485 (753-652) on a 750-362 CODESYS Forge talk (Post)
Forgot to describe the pictures. Modbus1: is the actual configuration in codesys 3.5 Modbus2: is the config in WAGO I/O Modbus3: is the configuration from the old one with Beckhoff twincat (we are changing from Beckhoff to wago and codesys)
Last updated: 2024-02-08

Post by mehakfatima on Need Help Configuring Energy Analyzers via Modbus TCP & RTU (RS-485) in CODESYS 3.5 CODESYS Forge talk (Post)
Hello everyone, I am currently working on reading data from energy analyzers using Modbus TCP and RTU (RS-485). In my previous software, I used the following method to add slave devices (i have attached the image) and configure registers: Add the Modbus slave device. Configure the communication parameters (baud rate, parity, etc.). Define the registers and their addresses for data retrieval. Now, I am trying to achieve the same in CODESYS 3.5, but I am not sure how to configure the Modbus master, add slave devices, and set up the registers properly. If anyone has experience with Modbus TCP/RTU setup in CODESYS 3.5, I would really appreciate your guidance! A step-by-step explanation or any references/tutorials would be extremely helpful.
Last updated: 2025-03-13

Post by nickelwater on Fix compiler version in SP18+ CODESYS Forge talk (Post)
Is is possible to use the compiler "Fix Version" in SP18+? I have noticed that in SP17 and below, the option is available in the compiler options under project settings, but in versions 18+ it is unselectable. The help topic does not provide any information.
Last updated: 2024-07-21

Post by reinier-geers on Compile problems CODESYS Forge talk (Post)
Ive got a version 16 with no problem. Ive got a version 19 with no problem. But the version 18.4 has problems. WHY ??? 18 is an version 16 updatet.
Last updated: 2024-02-19

Post by gediminas on Datasource OPC UA client system failure CODESYS Forge talk (Post)
I haven't actually found an answer yet. It happens quite rarely, so testing and diagnostics are complicated. I've updated the software with every SP and add-on updates released, but it's probably a Kernel driver issue.
Last updated: 2025-02-09

Post by yann2021 on SysProcessExecuteCommand CODESYS Forge talk (Post)
Hello, I have this code who worked fine in an other project with a previous SP. Why do I have now errors when I generate this code...? Who can help me pls? Many thanks for your help.
Last updated: 2024-02-04

Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Okay i will try. I tried already the different settings. The CodeSys version i use, is CodeSys 3.5 SP20 Patch 3. The device which i use is CodeSys Control For Raspberry PI 64 SL version 4.13.0.0. The wiring should be okay because i'm using the Edatec ED-CM4IND-1432-4C(EU).
Last updated: 2024-11-07

Post by eschwellinger on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
please use latest version 4.9.0.0 and it is mandatory to have a user pi on your device.
Last updated: 2023-09-11

Post by kjubidoo on OPCUA Ctrl-Node fehlt CODESYS Forge talk (Post)
Hallo allerseits, ich habe eine OPCUA-Verbindung zu meinem PFC200 Controller eingerichtet und vermisse die Ctrl-Node unter "DeviceSet". Ich nutze Codesys 3.5 SP19 Patch 4, Runtime V4.10, Firmware 03.10.08(22) und UaExpert 1.71. Hat jemand eine Idee? Beste Grüße
Last updated: 2023-12-04

Post by strannik on SoftMotion SML CODESYS Forge talk (Post)
I use SoftMotion Light libraries in my CodeSys 3.5 project. Activated the license. But probably not all the actions were completed. In the configuration of the axes A message that the driver is running in demo mode. Please tell me what complete actions need to be performed. Thanks
Last updated: 2024-07-06

Post by andreiot40 on Step motor ECT60 Ethercat in codesys 3.5 CODESYS Forge talk (Post)
Thanks for your response. for Master in log i have : no slaves found, Interface could not be opened, could not open network adapters. Status : Not running FOR ETC60 There is nothing !!!
Last updated: 2024-08-15

Post by jobtc on Count alarms within a Class or Group CODESYS Forge talk (Post)
Is it possible within codesys 3.5 SP16 Patch 5, to get some data from the alarm manager? For example: i want to know how many alarms i have within a class Thx for the help
Last updated: 2024-09-13

Post by liamb on Unable to add alarm configuration object to project CODESYS Forge talk (Post)
I'm trying to add an alarm configuration object to a project in Codesys 3.5 SP12 however when I right click on application and try to add object there is no option for it. Is alarm configuration avaiblible on this service pack?
Last updated: 2024-09-24

Post by codesysdave on CoDeSys 3.5 SP20 "No Offline Help installed" CODESYS Forge talk (Post)
Can someone please post a link THAT WORKS for downloading and installing the Offline Help? This official link does nothing: ap-installer://codesys.com/package/install?id=47056291-63CB-4FAB-A706-99B8AF9114B6
Last updated: 2024-09-30

Post by oudom on Missing Button State Variable CODESYS Forge talk (Post)
My CODESYS 3.5 SP16 Patch 4 in the visualization Button property missing a configuration Button state variable. How do we activate the Button State Variable in the visualization as shown in the attach document?