Post by anonymous on Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Post)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part.I am able to capture the data of client side in wireshark but i am unable to capture it in the codesys. Heres the below part of code of client side. PROGRAM POU_udpclient_program VAR istep : INT := 1;//step variable for state machine xStart: BOOL;// Flag to start the UDP protocol iecSocketId: syssocket_interfaces.RTS_IEC_HANDLE;//socket handle for receiving iecCreateResult: syssocket_interfaces.RTS_IEC_RESULT; ipAddr: syssocket.SOCKADDRESS;//Socket address structure for receiving sIpAddress : STRING := '192.168.0.2'; wPort: WORD:= 12346; iecConnectResult : syssocket_interfaces.RTS_IEC_RESULT;//connect paramters sDataRec : STRING[255];//Buffer for received data xiRecBytes : __XINT;//number of bytes received iecRecResult : syssocket_interfaces.RTS_IEC_RESULT;//receive data parameters iecCloseResult : syssocket_interfaces.RTS_IEC_RESULT; END_VAR syssocket.SysSockInetAddr(sIpAddress,ADR(ipAddr.sin_addr)); ipAddr.sin_family := syssocket.SOCKET_AF_INET; ipAddr.sin_port := syssocket.SysSockHtons(wPort); CASE istep OF 1: //create socket IF xStart THEN iecSocketId:= syssocket.SysSockCreate(syssocket.SOCKET_AF_INET,syssocket.SOCKET_DGRAM,syssocket.SOCKET_IPPROTO_IP,ADR(iecCreateResult)); IF iecSocketId = syssocket_interfaces.RTS_INVALID_HANDLE THEN xStart := FALSE; istep := 1; ELSE istep := 2; END_IF END_IF 2: //connect to socket server using setoption iecConnectResult := syssocket.SysSockSetOption(iecSocketId,syssocket.SOCKET_SOL,syssocket.SOCKET_SO_REUSEADDR,ADR(ipAddr),SIZEOF(ipAddr)); istep := 3; 3: //receive data xiRecBytes := syssocket.SysSockRecvFrom(iecSocketId,ADR(sDataRec),SIZEOF(sDataRec),0,ADR(ipAddr),SIZEOF(ipAddr),ADR(iecRecResult)); istep := 4; 4: //close socket iecCloseResult:= syssocket.SysSockClose(iecSocketId); xStart := FALSE; istep := 1; END_CASE
Last updated: 2024-06-03
Post by rikkrt on Limited options
CODESYS Forge
talk
(Post)
Hi! I was downloading codesys for a school project, but I cannot seem to find where and how to get the other programming languages. When I try to create a new project, I only get the option to program in structured text. *see problemcodesys.png Does anyone know where I can get the other languages? Thanks in advance, Rik
Last updated: 2024-06-06
Post by andreag0 on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
Hello, anyone know how to get valiable value using a symbolic string name? For example: - send string to runtime using TCP/IP contains "GVL.TestINT" and get back the value. I need function that will translate the string to symbolic variable. Thank you. Andrea
Last updated: 2024-06-13
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by felipemsgarcia on Generic EtherCAT slave
CODESYS Forge
talk
(Post)
Hello all, I still couldn't find the answer. I wanted to know is if there is a generic EtherCAT slave object already in CODESYS that I can use for anything, remote IO, Drives, VFD's and so on, as long as I match PDO's. Is there such an object? Thank you!
Last updated: 2024-06-20
Post by koppit on SysComRead Timeout Parameter
CODESYS Forge
talk
(Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26
Post by exkrim19 on Unable to connect to this device
CODESYS Forge
talk
(Post)
What worked for me with this error was to go to Tools -> Update Raspberry Pi, select Install, and from the popup screen, there are options to change your installation (I changed it to single core, instead of multicore), and I was then able to connect to my Rpi 4.
Last updated: 2024-06-28
Post by rmaas on Responsive Design Example
CODESYS Forge
talk
(Post)
Hi, I just tried the example project with control WIN x64 and for me this is working correct. The only difference is that it is showing 'TabletPortrait' when i hold my smartphone in portrait mode and 'Monitor' when i hold my smartphone in landscape mode. This is because smartphone resolutions have increased i guess... You could check what resoution is detected and change accordingly in IsSmartphone method.
Last updated: 2024-07-04
Post by mucleus on What is the solution for "Application stopped on recovery switch request"?
CODESYS Forge
talk
(Post)
Hi, everyone. I am using CODESYS RTE and Profinet I/O or EtherCAT I/O. Occasionally (once every 1-2 months) the attached image occurs and the program stops. I want to know why this phenomenon occurs and how to solve it. I attached log. Please help me. Thanks.
Last updated: 2024-07-05
Post by hermsen on Raspberry Pi 4.12.0.0 SL also stops after 15s
CODESYS Forge
talk
(Post)
After installing this new 4.12.0.0 SL version on my RPi5 8GB and the latest bootloader, the runtime disappeared after 15secs. The bootloader my pi uses is from 2024-06-11. I was able to resolve this issue using this post: https://forge.codesys.com/forge/talk/Runtime/thread/be25c0ff66/ The workaround works for me.
Last updated: 2024-07-06
Post by stiller on OPC UA RPI 4.8.0.0 Status Code / "out of range"
CODESYS Forge
talk
(Post)
Hello, I have an OPC-UA server with an information model. For many values, there is a defined range (e.g., 0 to 100). If a client enters a value outside this range (e.g., 120), the StatusCode should change to Bad. How can I accomplish this? Any help is appreciated! Thank you in advance. Best regards, Christian Stiller
Last updated: 2024-07-10
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
Post by mmpl on Array to String
CODESYS Forge
talk
(Post)
I would like to create one large JSON string from an array of objects, where each object contains a value. My current approach involves using a for loop and string concatenation, but with 20,000 elements in the array, this method takes almost 7 seconds and negatively affects the PLC scan time. Is there a more efficient way to accomplish this?
Last updated: 2024-07-18
Post by mmpl on Array to String
CODESYS Forge
talk
(Post)
I would like to create one large JSON string from an array of objects, where each object contains a value. My current approach involves using a for loop and string concatenation, but with 20,000 elements in the array, this method takes almost 7 seconds and negatively affects the PLC scan time. Is there a more efficient way to accomplish this?
Last updated: 2024-07-18
Post by trusty-squire on Confused by dwIpoTime input for SMC_Interpolator
CODESYS Forge
talk
(Post)
OK, that makes sense. Because the FB is provided a specific interval period, it would change the target position accordingly based on the time it "thought" elapsed. If it has the wrong interval provided, it updates the target positions every cycle incorrectly so the axes will end up moving faster or slower. Thanks!
Last updated: 2024-07-22
Post by timvh on Array to String
CODESYS Forge
talk
(Post)
The string_Util_Intern is not the library I referred to. With a CONCAT function (also with the string util library) a search is done for the NULL character. If you concatenate 20000 characters to one string, then the longer the string, the longer it takes to find this NULL character.
Last updated: 2024-07-24
Post by marks on Regarding trend storage access error
CODESYS Forge
talk
(Post)
I had this problem when running the application as a Simulation. When I wrote it to the Pi all worked as expected. If this isn't the case for you, we've seen some issues with sqlite on the Pi's - so reset Origin and re-download may help in that case. Good luck, Mark
Last updated: 2024-07-24
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Hello just to give more feedback the error I get is "ERROR_UNKNOWN :represents raw value of 5110" in File.DirOpen. The xDone never gets true, and I never get the listing of files (csv files in this case). In the hDir i get the value of 0 for a DWord!?
Last updated: 2024-07-31
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Thanks for the answer Tim. I am using the codesys version 3.5 SP16, is this also affected or only after version 19? But now at leastI know that is an acess problem to the file and not something else. Unfortunately the link you posted on 2023 are now dead, but I will investigate!
Last updated: 2024-08-01
Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port
CODESYS Forge
talk
(Post)
I've also noticed that when I turn off "enp1s0", suddenly the source IP for the ModbusTCP changes to that of "enp2s0", which is what makes sense to me. When I turn it back on, the source IP remains that of "enp2s0".
Last updated: 2024-08-01
Post by flappyman on licenses question
CODESYS Forge
talk
(Post)
I hope this tread will be able to help me. I got your new licenses and it was working perfectly fine. Unfortunately, my PLC got severely damaged and it can not run anymore. Is it possible to somehow release the license so I could use it again. I have all information for the device and can provide it.
Last updated: 2024-08-05
Post by maxsus on Visu Frame-configuration___text will not work
CODESYS Forge
talk
(Post)
Hello I have a problem with the Frame-configuration. In the picture below you can see that I set the Editor Type to variable. If it would be text it would work, but it wasnt variable anymore. Thanks for your time. Sorry, my codesys is in German.
Last updated: 2024-08-20
To search for an exact phrase, put it in quotes. Example: "getting started docs"