Post by damian177 on Codesys Control for Linux SL
CODESYS Forge
talk
(Post)
everything works well.
Last updated: 2024-09-08
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Hello, the following store software may be required? https://store.codesys.com/en/codesys-ethercat-master-sl.html Please if anyone has this software installed can you tell me if it has VLAN tagging?
Last updated: 2024-09-09
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
I have the same idea, I'm very interested in this..., please let me know if you can find it..., if you can give me your contact so we can communicate... thank you.
Last updated: 2024-09-09
Post by gustavocsw on MQTT memory leak problem
CODESYS Forge
talk
(Post)
Hello everyone, I'm using the IoT Library to implement the MQTT communication with my local broker server in order to publish and subscribe at specifics topics to share and consume information about my application. But, it seems that are occurring some memory leak problem in a "high" frequency (more than 10 Hz) subscribe process. I follow the same method as in IoT Lib exemples, and at first looks perfect but my PLC was rebooting frequently and when I check its memory usage that was increasing as fast as the subscribe massage was sent. I'm using a WEG PLC410 and a WEG PLC500, and this error occurred in both of them (including in CODESYS Control Win x64). The application sends to the system a message JSON with the float payload Ex. {"data" : 0.8500}, but this happens with a INT, or BOL as well. I use the follow code in my application to find the value: //FindFirstValueByKey VARs PROGRAM JSON_VELO VAR //------Setting the JSON Subscriber to Set the Relay Value jsonDataVelo : JSON.JSONData; jsonByteArrayReaderVelo : JSON.JSONByteArrayReader; xST1okVelo : BOOL; FindFirstValueByKeyVelo : JSON.FindFirstValueByKey; jsonElementVelo : JSON.JSONElement; xDoneReaderVelo : BOOL; xDoneFindVelo : BOOL; //STRING and WSTRING for Subscribe the massage sPayloadJsonVelo : STRING := 'opa'; psPayloadJsonVelo : POINTER TO BYTE := ADR(sPayloadJsonVelo); //wsPayloadJsonRelaySet : WSTRING := "opa"; wsPayloadJsonVelo : WSTRING := STRING_TO_WSTRING('opa'); pwsPayloadJsonVelo : POINTER TO WORD := ADR(wsPayloadJsonVelo); lrVelo : LREAL; xKeepAliveVelo : BOOL; xSetVelo : BOOL; RSSet : RS; LIMPAR : STRING; //Find the msg end sFindVelo : STRING := '}'; psFindVelo : POINTER TO STRING := ADR(sFindVelo); iLenVelo : INT; iSizeVelo : INT := 12; udiContMsg : UDINT; END_VAR // FindFirstValueByKey CODE // Relay Set configuration xSetVelo := MQTT_SUBSCRIBER.RSVelo.Q1; IF xSetVelo THEN xKeepAliveVelo := TRUE; END_IF IF xKeepAliveVelo THEN udiContMsg := udiContMsg + 1; iLenVelo := TO_INT(StrLenA(psPayloadJsonVelo)); iSizeVelo := iLenVelo - TO_INT(MQTT_SUBSCRIBER.udiPayloadSizeVelo); StrDeleteA(psPayloadJsonVelo,iSizeVelo,iLenVelo); wsPayloadJsonVelo := STRING_TO_WSTRING(sPayloadJsonVelo); pwsPayloadJsonVelo := ADR(wsPayloadJsonVelo); //MQTT.ConvertUTF8toUTF16(sourceStart:= ADR(sPayloadJsonVelo), targetStart:= ADR(wsPayloadJsonVelo), dwTargetBufferSize:= TAM, bStrictConversion:= 1); //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := TRUE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := xDoneReaderVelo, wsKey := "data", diStartIndex:= 0, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); IF xDoneFindVelo THEN lrVelo := jsonElementVelo.value.lrValue; //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := FALSE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := FALSE, wsKey := "data", diStartIndex:= 1, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); xKeepAliveVelo := FALSE; GVL.xSetVeloRead := TRUE; END_IF END_IF And this to subscribe at the topic: //SUBSCRIBE VAR: //----------------- Subscribe Velocity ----------------------- MQTTSubscribeVelo : MQTT.MQTTSubscribe;//Variable MQTTSubscriber block -X - function-X wsTopicSubscribeVelo : WSTRING(1024) := "CORE/odometry/GET/data/simp"; // Topic to publish a message sSubscribeMassageVelo : STRING; udiPayloadSizeVelo : UDINT; xSDoneVelo : BOOL; xSErrorVelo : BOOL; xReceiveVelo : BOOL; eSTypeVelo : MQTT.MQTT_ERROR; eSMQTTErrorVelo : MQTT.MQTT_ERROR; RSVelo : RS; udiCont : UDINT; //SUBSCRIBE CODE: MQTTSubscribeVelo( xEnable:= MQTT_CLIENT.xConnection_Broker AND NOT xSErrorVelo AND NOT JSON_VELO.xKeepAliveVelo, pbPayload:= JSON_VELO.psPayloadJsonVelo, udiMaxPayloadSize:= SIZEOF(JSON_VELO.sPayloadJsonVelo), udiPayloadSize => udiPayloadSizeVelo, mqttClient:= MQTT_CLIENT.ClientMQTT, wsTopicFilter:=wsTopicSubscribeVelo, xDone => xSDoneVelo, xError=> xSErrorVelo, xReceived => xReceiveVelo, eMQTTError=> eSMQTTErrorVelo ); RSVelo(SET := xReceiveVelo, RESET1 := JSON_VELO.xKeepAliveVelo);
Last updated: 2024-09-09
Post by paulpotat on cm4 runtime problem
CODESYS Forge
talk
(Post)
Hello again, After looking into it, I noticed that the release note of "CODESYS Control for Raspberry PI 4.13.0.0" mentions a bug fix titled "Support Compute module 4". Is it possible to have more details about this fix from the CodeSys team please ? Because I have several CM4 boards with the same hardware revision / OS but some of them works with the 4.10 runtime and others only works with the 4.13 runtime...
Last updated: 2024-09-09
Post by dkugler on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
you can give this code snippet a try. It's extracted and simplyfied from my code: Install VisuElemBase lib if not installed yet. Execute in visu task: VAR pClientData : ARRAY [-1..100] OF POINTER TO VisuElemBase.VisuStructClientData; END_VAR VisuElemBase.g_ClientManager.BeginIteration(); pClientData := VisuElemBase.g_ClientManager.GetNextClient(); WHILE pClientData <> 0 DO pClientData[pClientData^.GlobalData.GlobalClientID] := pClientData; END_WHILE You have to make shure every no longer updated pointers in the array have to be deleted and no longer used by your code! Usage of this pointer access at your own risk :-) Works with SP16. From SP17 and newer there will be warnigs etc. using this solution as I remember. It will be great, if Codesys publishes a example or give a hint how to accesse this client values with the VisuUtil lib or other future-proof way!
Last updated: 2024-09-09
Post by gustavocsw on MQTT memory leak problem
CODESYS Forge
talk
(Post)
I'm using the V3.5 PS19 Patch4. That is a problem with that version with IoT Lib?
Last updated: 2024-09-09
MQTT memory leak problem
CODESYS Forge
talk
(Thread)
MQTT memory leak problem
Last updated: 2024-09-09
Post by eschwellinger on MQTT memory leak problem
CODESYS Forge
talk
(Post)
which version are you using? is this latest available version?
Last updated: 2024-09-09
Post by eschwellinger on codesys VLAN tagging
CODESYS Forge
talk
(Post)
no we'll an example for it but need some time.
Last updated: 2024-09-09
Post by docker on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
Hi mate, With this snippet i was able to see the lastusage variable count, but it would not iterate between clients? i was only able to access the data of the target visu. it threw an error with the array of pointers stating it was not able to convert etc. also when i tried it with the while loop it created an endless loop and crashed the program. any ideas? Thankyou
Last updated: 2024-09-10
Post by dkugler on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
https://forge.codesys.com/forge/talk/Visualization/thread/b12815b7cd/#877a there was a discussion about this thematic searching in the talk helps to learn from others... good luck, Dave
Last updated: 2024-09-10
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Last updated: 2024-09-10
Webvisu client connection monitoring
CODESYS Forge
talk
(Thread)
Webvisu client connection monitoring
Last updated: 2024-09-10
Post by runtimevictor on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Thank you very much for answering, I look forward to the example. As soon as the example or documentation is available, please let me know... thank you.
Last updated: 2024-09-10
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
Hi Everyone, For a fast monitoring system I am using Ethercat oversampling and timestamping inputs. As the customers has a lot of different configurations out in the field, we went for a dynamic Ethercat configuration. Already got the whole detection chain working but now I am stuck since two days in debugging the configuration. Here are my quesitons: I extended the dynamic config example for the EL3632 16#0E303052: //EL3632 pSlave^.SetDCSettings(TRUE,TRUE,80,80,TRUE,4000,0,0); pSlave^.AddSyncManager(16#1000,128,16#26,TRUE,3); pSlave^.AddSyncManager(16#1080,128,16#22,TRUE,2); pSlave^.AddSyncManager(16#1100,0,16#4,TRUE,1); pSlave^.AddSyncManager(16#1110,214,16#20,TRUE,0); pSlave^.AddFMMU(0,214,0,7,16#1110,0,1,1); pSlave^.AddFMMU(0,1,0,0,16#80D,0,1,1); xKnown := TRUE; This leads to a PLL Error for these devices. I double and triple checked the configuraton, but cannot find the issue. There seems to be one difference: the config dialog creates a startup parameter: 16#10F3:16#05, Name: Command_0, Value:0. Bitlen: 16, Stop on fault: false, jumpt at fault: false: next line: 0 a) I do not find information on how to set this in my code. Can you help me there? b) Without trying to set the value, I get a PLL error for these devices in the master log. Is the config wrong? c) Do I need to set the Master to Autoconfigure or Manual? I used autoconfigure for my tests. The stack creates input data addresses for the slaves input data range (pSlaves[i].InputData) which are different from those created when I use the Engineering tools dialogs to configure Ethercat. Specifically, the addresses seem to be aligned at 16 byte boundaries when they are created using the engineering tool, but may appear at uneven addresses when I use the script in dynamic config. I did not try to access ULINT at uneven addresses yet, but I am suspecting this may be a problem. Do I need to manually align the addresses ? Any help is appreciated...
Last updated: 2024-09-10
Post by alex-at-xana on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
Ah - forgot another question as it may be related to the PLL problem: I am executing a 4ms cycle. I do not call (from what I know) the Ethercat_MAster periodically in my program. The bus cycle task is set to the Ethercat task. I would assume that the master should send 250 frames per second. Yet, the status of the master says it transmits 500 frames per second which would indicate that the master is called twice. Any ideas there?
Last updated: 2024-09-10
Persistent variables not working for Control Win
CODESYS Forge
talk
(Thread)
Persistent variables not working for Control Win
Last updated: 2024-09-10
Persistent / Programme change
CODESYS Forge
talk
(Thread)
Persistent / Programme change
Last updated: 2024-09-10
Post by talhaali on Persistent variables not working for Control Win
CODESYS Forge
talk
(Post)
Hi everyone, I am facing issues with persistent retain variables. It was working fine. I added a few new Persistent variables and it stopped working. If I do cold reset it holds persistent variable values. But when I close control win gracefully, and opens it again then it does not. Even, it is not saving ret file in application.
Last updated: 2024-09-10
Post by bruceae on Ethernet/IP Scan
CODESYS Forge
talk
(Post)
Hello, I have a robot configured as a Generic Ethernet Module under Ethernet/IP Scanner. I can not see the change of state of the outputs coming from the robot on the codesys side in real-time. (The robot has it's own internal program that would changes the values of remote outputs 0-3 off and on). Also when I send data down to the inputs of the robot it doesn't transfer over as expected. As an example I'll send to the robot's input bit 0 a value of 1. It doesn't see that value change. However, when I write that input bit 0 back to a value of 0, the robot changes state and shows a value of 1. And if I change the state of a different bit, the other bits update properly, except for the bit that I changed. Any advice would be greatly appreciated, and if anything else is needed let me know.
Last updated: 2024-09-10
Post by talhaali on Persistent variables lost
CODESYS Forge
talk
(Post)
Hi, did you get any solution. I am facing similar problem. I lost all the values
Last updated: 2024-09-10
Post by talhaali on Persistent / Programme change
CODESYS Forge
talk
(Post)
Hi, did you get any solution for this.
Last updated: 2024-09-10
Ethernet/IP Scan
CODESYS Forge
talk
(Thread)
Ethernet/IP Scan
Last updated: 2024-09-10
Post by esmith on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins
CODESYS Forge
talk
(Post)
I think I am having a similar issue. Have you found out what was causing this problem?
Last updated: 2024-09-10