Post by eschwellinger on Problems with Raspberry Pi - IoDrvGPIO library
CODESYS Forge
talk
(Post)
update device and update gpio devices by rightclick on the device tree
Last updated: 2024-04-05
Post by dawidr on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module
CODESYS Forge
talk
(Post)
Last updated: 2024-04-07
Post by eschwellinger on Power off
CODESYS Forge
talk
(Post)
impossible to help without the information which drive it is and which driver is used(DS402 genereic or any specific driver)?
Last updated: 2024-04-09
Post by ademarvribeiro on Load (or Read) File from PLC
CODESYS Forge
talk
(Post)
Online -> Read file from PLC. Go online after download, sometimes the program Running and programm saved in PLC are diferent.
Last updated: 2024-04-12
Post by ademarvribeiro on Could not be resolved - Library error
CODESYS Forge
talk
(Post)
Hello. Did you try delet this library and rebuild the Project?
Last updated: 2024-04-12
Post by wiresplus on warning message
CODESYS Forge
talk
(Post)
00 I have the same issue, and no answers on any forums that I can see.
Last updated: 2024-04-13
Post by dkugler on Text List Fallback Value
CODESYS Forge
talk
(Post)
why you adding this ' ' ? you don't need them in the text field :-) delete them, write only Unknown and everything will be as expected
Last updated: 2024-04-18
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
I'm digging into it and see that sm3_shared is nested in the library manager raspistepper->sm3_drive_poscontrol->sm3_shared but I get errors
Last updated: 2024-04-20
Post by m83coding on Raspberry Pi Codesys SPI Master
CODESYS Forge
talk
(Post)
Hello, I am trying to control shift registers 74HC596 and 74HC165 via Raspberry PI with SPI interface. So far I did it with a Microcontroller and now I wanna upgrade my Projekt with Raspberry Pi and Codesys Software to be more flexible. I tried to adapt PiFace Function Block to just send or recive a 8 bit via SPI interface of the my Raspberry Pi. With following code (see attached screenshots) * PLC_PRG * PiFaceDigital * PiFaceDigital.write8 * PiFaceDigital.read8 I have a signal at SCK and MOSI pin of the PI, so far so good. But I really struggle with the unterstanding of the code. Is there some detailed description of each line of code? Or is there somebody in the community who can explain each line of code? Or is there a more simple way to send / recive 8 bit via SPI? Manuel
Last updated: 2024-04-23
Post by peterned on CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that?
CODESYS Forge
talk
(Post)
Hi, I have a XY system and use a CNC file to move it. Everything works OK, except for the following: when CNC execution starts, the system rushes at high speed to (X=0, Y=0) point, and only then goes to the first line of the CNC file. If one of the axes is near 0, the system jumps and immediately stops with an error. In the CNC file settings (screenshot attached) I specified low default values for speed/acceleration and a start position different from 0,0 - but all that is ignored. Any idea how to avoid that move to 0,0 ? Thanks.
Last updated: 2024-04-26
Post by valenting on Problem with Licenced Software Metrics
CODESYS Forge
talk
(Post)
Update : I updated my project's compiler version to the latest and it finally works
Last updated: 2024-04-29
Post by alex2 on Codesys SVN
CODESYS Forge
talk
(Post)
To summarize, we have no choice but to use SVN... And what about the sp16?
Last updated: 2024-05-01
Post by tiagomachado88 on suggestion: collapse Ladder networks similar to Siemens' TIA Portal
CODESYS Forge
talk
(Post)
Hello, It's just a suggestion to facilitate viewing and monitoring! Regards, Tiago
Last updated: 2024-05-03
Post by eschwellinger on New Ladder Diagram conversion does not work due to missing features
CODESYS Forge
talk
(Post)
please send project archive and steps to repeat to - my question in the CODESYS store
Last updated: 2024-05-14
Post by corriibme on Read Serial Number of PLC
CODESYS Forge
talk
(Post)
I have recently used this example from @Brine, and it worked. Thanks
Last updated: 2024-05-21
Post by wbj0t on connect IDE to plc that uses modem ppp
CODESYS Forge
talk
(Post)
Hello everyone! I have an PLC device that uses modem ppp connection to the internet with white IP. Device PPP connection with modem operator established, so I can connect to this device via SSH also within Codesys IDE (check version, info, etc...) BUT, I cant establish connection to this device in the device gateway options for application upload and debugging. How can I do this? Im trying set my device remote IP and port 11740, but, as I understand, it is wrong decision, because the next logic in this connection: local W10 service (Codesys Gateway) listen on 1217, then (some how) this service scanning local networks for seeking any local IP which listening on port 11740, and then connects and writes there. OR IM WRONG?:) W10 tool 'Test-NetConnection' with parameters 'ip -Port 11740' succeeded with True. Need some help, please :)
Last updated: 2024-05-21
Post by alexgooi on FB_INIT in library
CODESYS Forge
talk
(Post)
Hi Paro, I have tried this and it seemed to have solved the problem, thank you very much!
Last updated: 2024-05-23
Post by zer0g on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, Thank you for your suggestion but the problem is fixed after I disabled and enabled the network adapter from Windows settings.
Last updated: 2024-05-30
Post by viksym on Get text from textlist
CODESYS Forge
talk
(Post)
Thank you, but sadly I already tried this and it also doesn't work. It's not doing anything.
Last updated: 2024-06-03
Post by codesysdave on Using globals without a prefix (bMyTag vs GVL.bMyTag)
CODESYS Forge
talk
(Post)
Over 5 years later, you helped me tremendously. Thanks. And great kitty picture.
Last updated: 2024-06-04
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
4.11 appears to solve the problem. Thanks for your help. I had first installed the 64-bit version of RPiOS, but looking at various posts and the product's page on the store which only lists 32-bit compatibility, I downgraded to the 32-bit version. I did this before trying 4.11, and it did not solve the problem. Thus my working system is 32-bit, and I am wondering if I can go back to 64-bit or not. An 64-bit OS is not listed as compatible on the store's web page, but when installing there actually is a 64-bit version listed (automatically chosen when installing on 64-bit, but otherwise greyed out). Is 64-bit supported and the website is out-of-date, or is that some kind of work-in-progress?
Last updated: 2024-06-13
Post by paro on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
CmpApp https://forge.codesys.com/prj/codesys-example/application-man/home/Home/
Last updated: 2024-06-17
Post by bruno-roth on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive
CODESYS Forge
talk
(Post)
You could use the FBs ETC_CO_SdoWrite and ETC_CO_SdoRead
Last updated: 2024-06-19
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
I am now executing the process in a separate task with lower priority, but unfortunately, the connection to the master is still interrupted.
Last updated: 2024-06-21
Post by nano on variables between two applications
CODESYS Forge
talk
(Post)
use an gvl for interact variables beetween apps and threads. this should work
Last updated: 2024-06-23