Post by paulg on RasPi CAA Serial example - unexpected behavior during debug CODESYS Forge talk (Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06

Post by mubeta on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
How are the servo drives controlled? EtherCAT, step/dir pulses, other? CANOpen, 1 Mb/s, bus load 35%, cycle time 2ms. Another thought is that - if it's step/dir pulse based control - the pulses from the PLC to the drive are getting missed/lost at high frequencies? If that's the case then there would be multiple troubleshooting steps/corrections that could be investigated. Here, it seems to me that we are getting completely off track with the observed problem. You could try to create a simplified program I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. However, in emulation I was interested in checking other aspects of the process, not this specific one which is for real a correction made necessary after the fact. The part of the program that does this correction with the function mentioned in the topic, came up from its origins, but I didn't know or didn't think it was really useful. A scruple that later turned out to be necessary. However, for now I do not think I will spend any more time on this verification, already lacking any to do my normal. I remain amazed, however, that a function intended to correct the axis position with the motor in motion and that it should not interfere with this, in fact instead changes behavior as the motor speed changes. Mah! When you manually control the motor directly from the servo drive software at the speeds you are calling for, does it move precisely to the target position? The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem. What I need to resolve is the fact that a clutch specially placed at a certain point can slip and, therefore, I have the undeniable need to phase the 'prime mover' to the mechanical position of the machine, detected by a cam for each turn, in order to properly stop at its optimum point. Which for now I have ruled out doing. In fact, if I really have to say, since we have now gone brutally OT, I originally thought that this clutch should only come into action in cases of extreme necessity, as happens in most trials. But this one, the way it is made, slips more easily than I could estimate and the servo-controlled 'prime mover,' and the machine, get out of phase, maybe by a little, but frequently, and when the machine work at it's high speed, (in fact all of the time), I can't adjust properly the 'prime mover' position at fly.
Last updated: 2025-01-18

Post by struccc on Inheritence of struct, CODESYS Forge talk (Post)
Strangely reminds me to my struggles... Want to do something "Elegant", reusable, universal, practical... In CODESYS??? 🙃 First of all, before you get too deep into this: If you could find a way, to make a "universal" log entry object, containing the variable length data itself, you wouldn't be able to store them in an array, or access them like an array, or pass them by value as a type. (please correct me, if I'm wrong, incorrect, or not precise). Because... Basically you can't declare a type with variable memory footprint. This is a very deeply embedded characteristic of CODESYS, and all IEC 61131-3 systems, and it has many reasons behind. And yes, it is a very common trap / mistake, to forget about. So, with a log entry - I guess - it's pretty much the purpose: store data and metadata together, and then handle it in a uniform way. There are ways to handle this, really depends on what is the purpose. For example: 1. Entries with fixed length (Maybe it is not as evil as it looks for the first time. Depends on the situation, but definitely the fastest and easiest code) You can have your base object, with an internal, fixed length string or byte array variable. I would go with a string, and call it _Data.; And then you can make properties, like As_Bool, As_Int, As_Real... In the 'set' accessors, you can do like: pReal := ADR(_Data); // POINTER TO REAL As_Real := pReal^; In the 'get' accessors, evidently: pReal := ADR(_Data); // POINTER TO REAL pReal^ := AS_Real; Or, can use ANY type, if you are not obsessed with variable / property like access: 2. Fixed length, but nicer First, some disadvantage to any values: - You can only assign values with write access. No literals, constants, etc... - Can only be used as input variable of function or function_block - Therefore, stg you could reach: LogEntry.Initialize (stVariable|rVariable|iVariable|xVariable); Just a quick example (it's funny to play with ANY): Be careful it was not tested. I'm sure can be done better, please feel free to comment FUNCTION_BLOCK FB_LogEntry VAR_INPUT MsgClass : UDINT; // Like DEBUG, WARN, ERR... MsgCode : UDINT; // Like Errors.ERR_FAILED MsgTS : DT; // The timestamp END_VAR VAR _Data : STRING(80); // Our data container... _Descr : __SYSTEM.AnyType; // A standard descriptor for our data, containing TYPE_CLASS, address and size END_VAR METHOD SET_Value : BOOL VAR_INPUT anyValue : ANY; END_VAR VAR I : DINT; diSize : DINT; pStr : POINTER TO STRING; END_VAR // Check what did we receive in anyValue. diSize := anyValue.diSize; // We use constant __SYSTEM.TYPE_CLASS to identify the received data type CASE anyValue.TypeClass OF // Maybe we don't want to store references, pointers... and who knows what else... __SYSTEM.TYPE_CLASS.TYPE_REFERENCE, __SYSTEM.TYPE_CLASS.TYPE_POINTER : SET_Value := FALSE; // For the planned types we will be just fine. TYPE_CLASS.TYPE_BOOL, TYPE_CLASS.TYPE_INT, TYPE_CLASS.TYPE_REAL : SET_Value := TRUE; // Optionally string can be handled separately, maybe we have received STRING(255), but practically it is shorter than 80 bytes... TYPE_CLASS.TYPE_STRING : pStr := anyValue.pValue; diSize := MIN(anyValue.diSize, LEN(pStr^) + 1); // Get the actual size, and rewrite the received structure member diSize := MIN(SIZEOF(_Data), diSize); // Can chop down the received string to our length... SET_Value := TRUE; // Maybe want to play a little bit more here, to narrow down or convert datatypes, etc... // Or just reject any other datatype ELSE SET_Value := FALSE; RETURN; END_CASE // Fail, if the received value is still larger than our container... IF diSize > SIZEOF(_Data) THEN SET_Value := FALSE; END_IF // Here we should be ok, just set up the _DataType structure, and copy store the data IF SET_Value THEN THIS^._Descr.TypeClass := anyValue.TypeClass; // The typeclass is already filtered THIS^._Descr.diSize := diSize; // Set the (adjusted) size THIS^._Descr.pValue := ADR(_Data); // This will not change, just to be sure {IF defined (pou:SysMem.SysMemCpy)} SysMem.SysMemCpy(_DataType.pValue, anyValue.pValue, TO_UDINT(anyValue.diSize)); {ELSE} // An ugly replacement MemCpy FOR I:=0 TO diSize - 1 DO _Descr.pValue[I] := anyValue.pValue[i]; END_FOR {END_IF} // Otherwise, in case of failure maybe better set an empty value (overwrite the former data descriptor) ELSE THIS^._Descr.TypeClass := TYPE_CLASS.TYPE_NONE; THIS^._Descr.pValue := ADR(_Data); THIS^._Descr.diSize := 0; END_IF METHOD GET_Value : BOOL VAR_INPUT anyValue : ANY; END_VAR VAR I : DINT; END_VAR // We just have to serve the data, using the __System.AnyType structure received // Roughly we can say: IF anyValue.TypeClass = _Descr.TypeClass AND anyValue.pValue <> 0 // This should not be possible, already taken care of by Codesys (?) THEN {IF defined (pou:SysMem.SysMemCpy)} SysMem.SysMemCpy(anyValue.pValue, _DataType.pValue, TO_UDINT(MIN(anyValue.diSize, _Descr.diSize))); {ELSE} // An ugly replacement MemCpy FOR I:=0 TO MIN(anyValue.diSize -1, _Descr.diSize - 1) DO anyValue.pValue[I] := _Descr.pValue[I]; END_FOR {END_IF} // Just to make sure, that our string is terminated... IF anyValue.TypeClass = TYPE_CLASS.TYPE_STRING THEN anyValue.pValue[anyValue.diSize -1] := 0; END_IF GET_Value := TRUE; RETURN; END_IF // ... But can play more CASE anyValue.TypeClass OF TYPE_CLASS.TYPE_WSTRING : ; // Could do conversion TYPE_CLASS.TYPE_XSTRING : ; // Wow, I have to figure this out TYPE_CLASS.TYPE_PARAMS : ; // BTW, what is this, how to use? TYPE_CLASS.TYPE_ANYNUM : ; // ... END_CASE Be careful it was not tested. I'm sure can be done better, please feel free to comment 3. If you really want to do entries with variable size In a standard environment, it would be similar to the previous, except you dont have the container variable _Data, just use a pointer, practically _Descr.pValue At Initialize (SET_Value), you have to allocate the memory, would be easy with SysMem.SysMemAlloc - nowadays with SysMem.SysMemAllocData -, and you make sure to release it after use with SysMem.SysMemFreeData... SysMemAlloc was already hidden. The problem with this, that sooner or later your application will totally fragment the dynamic memory, and fail... So should look for some form of dynMaybe MemUtils.MemoryManager (I am not sure what is the status and the future of it). 4. You will end up by a LogEntry Factory ... 5. You could still have a look at this IEC Snippets BTW, Standard Codesys Logger is not a bad choice either. If you are really interested, I share some more code / library.
Last updated: 2025-03-09

Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS) CODESYS Forge talk (Post)
Hey Everyone, I'm having a bit of a struggle finding settings that will reliably maintain a connection between the webvisu and a touchscreen client. Every so often the HMI disconnects and will perpetually display the red spinning arrow with the "Error Happened, Will resume automatically" text. Power cycling the HMI to force a reconnect will re-establish comms. It seems to happen during periods of inactivity if that's a clue. From what I've gathered so far this seems to have something to do with the webvisu update rate, buffer size as well as the visu task scan rate. We first tried the default settings as follows: Webvisu Update Rate: 200 ms Webvisu Buffer Size: 50,000 Visu Task Scan Rate: 100 ms Priority 31 Other Tasks for Reference: Main Task Scan Rate: 100 ms Priority 1 Alarm Manager Scan Rate: 50 ms Priority 31 Ethercat Task: 4 ms Priority 1 This would disconnect some what regularly. We then made the following changes to try and stabilize: Webvisu Update Rate: 150 ms Webvisu Buffer Size: 75,000 Visu Task Scan Rate: 75 ms Kept other tasks the same. This seems to disconnect even more frequently. Also for reference the network is very small and only consists of the PLC, a small switch and the HMI. We're also not controlling frames from outside the visu program itself. The frame changes are all done natively. Any suggestions to get this to stop disconnecting? Oh and whatever the issue is the log does not record it. Figured I would ask here before opening a ticket. Thanks in advance for your help!
Last updated: 2023-09-06

Post by mubeta on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Thank you for your interest. Your answers are in line with what I knew, so at least it comforts me that I did not misinterpret the situation. However, I don't have an exact match as, for this project over the past few days I have: 1) I have gone back to leaving the various FBs of the motion always called, all of them, and in the state machine I use a boolean to activate the various useful Execute. (But in the future I want to go back and try the programming technique with which I wanted to develop this project); 2) For the occasional error: SMC_FB_WASNT_CALLED_DURING_MOTION perhaps it was due to the fact that I had set the Ethercat bus synchronism only at the CAN master level, but not at the level of individual drives. I have now also activated it for the individual drives and it does indeed seem to have been resolved, but having also adopted the programming technique mentioned in point 1), I cannot say whether this was the solution to the problem, or instead the previous point. Is there an error ‘regulator or start not set’ in the device log before the error ‘motion generating FB wasn't called for at least one cycle’? I can't answer that right now. By now the machine is running and I am no longer there, at this one. Also, I seem to remember that the 'fbeFBerror' drive structure (5-element array), does not cycle, BUT ONCE THE 5 EVENTS AFTER SWITCHING ON, IT DOES NOT UPDATE ANYMORE (but that's another issue), so diagnostics were not easy.
Last updated: 2024-07-24

Post by gorditron on I2C Communication with CODESYS Forge talk (Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag fĂŒr die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte fĂŒr den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer fĂŒr den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer fĂŒr die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle fĂŒr das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
CODESYS Control for PFC200 4.13.00 CODESYS IIoT Libraries SL 1.11.0.0 Application Based License: CODESYS Control Standard M I have (2) projects with similar code base and both using Wago PFC200. On the second project I am seeing 2 things that I have not been able to resolve: 1) Errors in the log under the Ethernet Item: IoDrvEthernet: [PCI\E1Q51CE62] Could not be found on target! Please check the Ethernet settings. 2) Exception for CPU Load. "Processorload watchdog: plcload=100, maxplcload=95" I have slowed down cyclic tasks on this project, even though on the first project there is actually more code - and it does not exhibit this behavior. In looking at the CPU loading via Linux 'TOP' command there appears to be 20% idle. So plenty of headroom (my opinion). In an effort to troubleshoot I have duplicated the target hardware on my bench. It ran overnight without a CPU load exception. On the test system, I have tried (3) version of the ethernet device. 3.5.16.0 3.5.17.0 and 4.2.0.0 Presently the log does not show the error, but status says the module reports an error. I really do not know if this issue is related to the CPU load exception. The issue does not appear to effect ethernet communications (ModbusTCP or SNMP or Webvisu or PuTTy into Linux Shell). On my test bench I have ModbusTCP slave simulators for all ModbusTCP slaves, but only (1) of the (5) SNMP devices present.
Last updated: 2025-01-21

Post by jeindhoven on Deploying to raspberry pi 5 hangs CODESYS Forge talk (Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23

Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64 CODESYS Forge talk (Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25

Post by imdatatas on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic CODESYS Forge talk (Post)
Dear @gseidel, Thank you for your clarification. I fully agree that the quadratic ramp type may have certain technical advantages. However, the main problem is backward compatibility and consistency across projects. In many automation projects, application developers rely on the fact that creating a new axis object will behave exactly the same way as in previous versions. With SoftMotion V4.18.0.0 and later, if an application developer adds an axis and overlooks the changed default, the motion function blocks behave differently than expected. In particular, since the Jerk value in SM3_Basic function blocks is ineffective in trapezoid ramp type, users are accustomed to leaving this parameter empty in their projects. In many existing projects, this variable has not even been assigned. When the default is changed to quadratic, the Jerk parameter suddenly becomes relevant, which can cause errors or unexpected behaviour in the field. From a user perspective, a default setting should always be the “safe” and “expected” option, while alternative options (like quadratic) can be selected manually if desired. Keeping the default as trapezoid ensures compatibility with existing projects and prevents unexpected issues, while still allowing users to benefit from quadratic ramps if they explicitly choose so. For these reasons, I kindly ask you to reconsider making trapezoid the default again. This would significantly reduce the risk of unexpected behaviour in future projects while still preserving the advantages of the quadratic ramp type for those who actively select it. Of course, the final decision is entirely at your discretion. Best Regards, imdatatas
Last updated: 2025-09-26

Post by acc00 on Redundancy Codesys Runtime, Synchronization CODESYS Forge talk (Post)
Hi, I’m currently testing the Codesys Redundancy application with 2 Raspberry Pi, with the idea is of using in my project 2 Wago PFC200 and 1 Ethercat Master with 2 Remote IO. After I configure the redundancy, and one Pi is Active and the other is Passive, if I disconnect the Ethernet cable of the Active, the Passive become Standalone, which is good, but the problem is the following: -When I recover the Ethernet connection, both stay Standalone. They will NOT Sync until I do it manually in the Codesys environment. How to make the synchronization automatically? -If both Pi/PLC stays Standalone, who is managing the IO? (Ethercat and Serial) I have done a test with an Modbus Slave, where I am sending a counter that increase every second. And I see that when both PLC are standalone, they both keep an active connection with the Slave, and both write values. This does not seem good, since according to this in my project both PLC would try to control the IO at the same time. Note: The Codesys have an option (greyed out, not possible to select) which says “Auto Sync”. What is the purpose, and why I’m not able to select it? I'm using Codesys Control for Rapsberry Pi 64SL Runtime in my test environment (2xRaspberry Pi 4), with the idea of using Codesys Control PFC 200 Runtime in my project (2xWago PFC200 and 1 Ethercat Master with 2x Wago 750-354 Ethercat Fieldbus Coupler). Using the last Codesys 3.5 version (SP19 PAtch 5). I'd appreciate a lot any help on this questions!
Last updated: 2024-01-22

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24

Post by testlogic on Sending Sequential Modbus TCP Packets CODESYS Forge talk (Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17

Post by xcqt on Oop best practice CODESYS Forge talk (Post)
Hi all, I’m currently trying to improve my OOP structure in CODESYS and I’m looking for some input on how others approach this. I understand the basics like inheritance, interfaces, abstract FBs, methods, and properties, but I still struggle a bit with the overall architecture and what’s considered clean or scalable in bigger projects. As an example, I’m working on two different energy meter function blocks: FB_EnergyMeter_MQTT reads data from MQTT (strings) FB_EnergyMeter_Modbus reads data from Modbus (words) Both have their own Update() method and implement the same interface (something like IF_EnergyMeter). Later on, I’ll probably add more meter types, but they should all behave the same from the controller’s point of view. Now, there’s a FB_GridControl block that needs power data from these meters. I see two options here: Define the meter blocks inside FB_GridControl and call them directly (for example fbModbusMeter.UpdateModbus()). Keep the meter blocks outside and pass them into FB_GridControl as interface references, so the control block doesn’t know which specific type of meter it’s dealing with. Option 2 feels cleaner and more flexible to me, but I’m not entirely sure how to handle the data flow in that case. Should I pass the meter instance through an interface reference (REFERENCE TO IF_EnergyMeter)? Or is there a better way to link the external FBs to the control block? I’d like to hear how you structure this kind of setup or see an example from someone who has done something similar. EDIT: I think i need to do something like this fbModbusUpdateInput(wInput:= wWordValue); fbMqttUpdateInput(strInput:= strStringValue); IF bUseMqtt THEN Meter REF = fbMqttUpdateInput; ELSE Meter REF = fbModbusUpdateInput; END_IF fbControl.SetMeter(UsedMeter := Meter); Or am i thinking wrong? Thanks, Thomas
Last updated: 2025-10-16

Post by vstrom on Codesys v3.5.22.10 - Internal error:System.AggregateException...Value cannot be null...Parameter name: expLValue CODESYS Forge talk (Post)
Hi to all, I receive an error when I try to compile a project that in v.3.5.21.50 have no problem. The error seems to comes out when I add the Visualization part into the project. The complete error is: [ERROR] Internal error:System.AggregateException: One or more errors occurred. ---> System.Exception: Internal error in Code ---> System.ArgumentNullException: Value cannot be null. Parameter name: expLValue at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentExpression(IExprementPosition pos, IExpression expLValue, IExpression expRValue, Operator kindof) at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentStatement(IExprementPosition pos, IExpression expLeft, IExpression expRight) at ..(IExpression , IExpression ) at ..(_IAssignmentExpression ,  ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.AssignmentStatementReplacer.ReplaceExpressionStatement(_IExpressionStatement expressionStatement, _ICompiledPOU cpou) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IForStatement forloop) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at ..(_ICompiledPOU ) at ..(_ICompiledPOU ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) at ..(_ICompiledPOU ) at ..(_ICompiledPOU& ) at ..() --- End of inner exception stack trace --- --- End of inner exception stack trace --- at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhase5_Codegenerator.(IList1 ) at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhase5_Codegenerator.(IScope5 , IList1 ) at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhase5_Codegenerator.(ICodegenerator ) at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhaseControllerGenerateCode.() at _3S.CoDeSys.Compiler35220.CompilerPhases.CompilerPhaseControllerGenerateCode.() ---> (Inner Exception #0) System.Exception: Internal error in Code ---> System.ArgumentNullException: Value cannot be null. Parameter name: expLValue at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentExpression(IExprementPosition pos, IExpression expLValue, IExpression expRValue, Operator kindof) at _3S.CoDeSys.LanguageModelManager.LanguageModelBuilder.CreateAssignmentStatement(IExprementPosition pos, IExpression expLeft, IExpression expRight) at ..(IExpression , IExpression ) at ..(_IAssignmentExpression ,  ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.AssignmentStatementReplacer.ReplaceExpressionStatement(_IExpressionStatement expressionStatement, _ICompiledPOU cpou) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IIfStatement ifst) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_IForStatement forloop) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Optimization.ExpressionStatementReplacerVisitor.visit(_ISequenceStatement sequenceStatement) at ..(_ICompiledPOU ) at ..(_ICompiledPOU ) at _3S.CoDeSys.Compiler35220.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) at ..(_ICompiledPOU ) at ..(_ICompiledPOU& ) at ..() --- End of inner exception stack trace ---<---
Last updated: 2026-04-22