Search talk: udint to uint

 
1 2 3 .. 170 > >> (Page 1 of 170)

Convertion Real to UDINT CODESYS Forge talk (Thread)
Convertion Real to UDINT
Last updated: 2020-05-18

Data conversion INT to UDINt (double) CODESYS Forge talk (Thread)
Data conversion INT to UDINt (double)
Last updated: 2017-01-30

2 byte array convert to uint CODESYS Forge talk (Thread)
2 byte array convert to uint
Last updated: 2019-04-30

How to convert UDINT to array of bytes ? CODESYS Forge talk (Thread)
How to convert UDINT to array of bytes ?
Last updated: 2023-03-10

Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Thread)
Converting UINT into bytes and converting 2Bytes into UINT
Last updated: 2023-12-08

explicit cast ENUM to UINT and vice versa CODESYS Forge talk (Thread)
explicit cast ENUM to UINT and vice versa
Last updated: 2021-03-11

Saving UINT data collected as String data to MMC CODESYS Forge talk (Thread)
Saving UINT data collected as String data to MMC
Last updated: 2007-08-17

Visu of floatting Number UDINT CODESYS Forge talk (Thread)
Visu of floatting Number UDINT
Last updated: 2022-05-25

Unterschied zwischen WORD und UINT Datentyp CODESYS Forge talk (Thread)
Unterschied zwischen WORD und UINT Datentyp
Last updated: 2005-12-21

R Trigger for UINT CODESYS Forge talk (Thread)
R Trigger for UINT
Last updated: 2022-06-20

Post by abjha1998 on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
Hi, I have been working on Codesys V3.5 with PFC200 controller and Can Gateway 750-658. I want to convert the incoming CAN data from bytes into UINT and for outgoing data bytes to UINT. Does anyone has experience with this kind of data? I tried few different ways but it doesn't seem to be working.
Last updated: 2023-12-07

Was ist der Unterschied zwischen WORD und UINT? CODESYS Forge talk (Thread)
Was ist der Unterschied zwischen WORD und UINT?
Last updated: 2008-04-14

UINT im Binärformat in eine Datei speichern CODESYS Forge talk (Thread)
UINT im Binärformat in eine Datei speichern
Last updated: 2020-01-08

using CTU block for uint counter CODESYS Forge talk (Thread)
using CTU block for uint counter
Last updated: 2016-08-15

Post by hanoues on setting date and time on CPX-E CODESYS Forge talk (Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21

Post by kislov on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
https://content.helpme-codesys.com/en/libs/CAA%20Memory/Current/CAA_Memory/Packing/PackBytesToWord.html + optional TO_UINT
Last updated: 2023-12-08

Post by paro on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, works in my case if I increase the timeout! to_udint(t#100ms) -> 100 -> 100us.. FUNCTION_BLOCK MODBUS_master_example_ST VAR initDone : BOOL := FALSE; aIPAddress : ARRAY [0..3] OF BYTE := [127,0,0,1]; clientTcp: ModbusFB.ClientTcp; // buffer to read input registers aDataInputRegisters : ARRAY[0..9] OF UINT; // some client requests clientRequestReadInputRegisters: ModbusFB.ClientRequestReadInputRegisters; xExecute: BOOL; uistart: UINT := 100; udiTimeout1: UDINT; END_VAR IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=aIPAddress, uiPort:=502, udiLogOptions := ModbusFB.LoggingOptions.All); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=1, udiTimeout:=1000000); // 1sec END_IF // call the client FB's clientTcp(); clientRequestReadInputRegisters(rClient:=clientTcp,xExecute := xExecute AND NOT clientRequestReadInputRegisters.xBusy ,uiStartItem:=uistart, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0]));
Last updated: 2024-05-30

Post by apurv on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07

Post by wildcard on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13

Post by voffi on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
There are some ways. One is to use SHR and SHL and it depends on your byte order in the data array. For Motorola byte order: PROGRAM PLC_PRG VAR u : UINT; byte_array_in : ARRAY [1..8] OF BYTE := [16#11, 16#12, 16#13, 16#14, 16#15, 16#16, 16#17]; byte_array_out : ARRAY [1..8] OF BYTE; END_VAR u := SHL(TO_UINT(byte_array_in[2]), 8) + TO_UINT(byte_array_in[1]); byte_array_out[1] := TO_BYTE(u); byte_array_out[2] := TO_BYTE(SHR(u, 8)); If it's Intel byte order just change 1 and 2 in the array indexes.
Last updated: 2023-12-07

Post by vipul on Multicast udp CODESYS Forge talk (Post)
Hi, Good afternoon can anybody help me with UDP Multicast code. I am not able to send or recieve data when code is dumped on linux device. Below is my code. Declaration: PROGRAM udp_multicast VAR oneTimeFlag :UINT :=0; state: INT:=0; driver: UDP.UDPDriver; //port : UDP.Port;//moved to GVL src_ipAddr_ud: UDINT; src_ipAddr_st:STRING := '192.168.127.155';//'192.168.1.155';//ipms ip address dst_ipAddr_ud:UDINT; group_ipAddr_st:STRING := '239.1.5.10'; //group_ipAddr_ud:UDINT; result: SysTypes.RTS_IEC_RESULT; //result of recieve function. bind: UDINT; //result of binding. resultCreate:SysTypes.RTS_IEC_RESULT;//result of port creation. timer:BLINK; temFlag :INT:= 0; post:INT :=0; checksumFunc:checksumXor; localStringBuf:STRING[500]; chksum:BYTE; dataBuffer:POINTER TO BYTE; checksumString:ARRAY[0..5] OF BYTE; recvSize:__XINT; errorCode:UDINT; joinGroupErrorCode:UDINT; END_VAR ************8 Implementation: IF oneTimeFlag <> 1 THEN oneTimeFlag:=1; resultCreate := driver.CreatePort(ADR(GVL.port)); src_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIPAddress:= src_ipAddr_st); GVL.group_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIpAddress:= group_ipAddr_st); GVL.port.IPAddress := src_ipAddr_ud; GVl.port.ReceivePort:= GVL.src_port;//port on which messages are expected. GVl.port.SendPort := GVL.dest_port; GVl.port.OperatingSystem := 0; //0- any system GVL.port.Socket :=3; //3- socket type is multicast bind := GVL.port.Bind(udiIPAddress:=src_ipAddr_ud,); GVl.port.JoinGroup(udiGroupAddress:= GVL.group_ipAddr_ud,udiInterfaceAddress:= src_ipAddr_ud,eLogCode=>joinGroupErrorCode); END_IF timer(ENABLE:=TRUE,TIMELOW:=T#100MS,TIMEHIGH:=T#100MS); IF timer.OUT = TRUE THEN GVL.port.Send(udiIPTo:=GVL.group_ipAddr_ud,GVL.dest_port,pbyData:=ADR(GVL.writeData),diDataSize:=SIZEOF(GVL.writeData)); ELSE SysMemSet(ADR(GVL.readData[0]),0,SIZEOF(GVL.readData)); result := GVl.port.Receive(ADR(GVL.readData),diDataSize:=SIZEOF(GVL.readData),udiIPFrom=>dst_ipAddr_ud,diRecvSize=>recvSize,eLogCode=>errorCode); SysMemMove(ADR(GVL.readDataBuf[0]),ADR(GVL.readData[0]),SIZEOF(GVL.readData)); END_IF post:=LEN(GVL.readDataBuf);
Last updated: 2024-01-14

Post by abjha1998 on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
Thank you for the reply. I got an error saying that MEM.PackBytesToWord(GVL.Actual_Speed_DUT_high,GVL.Actual_Speed_DUT_low) = u; is not a valid statement. Am I missing some library?
Last updated: 2023-12-08

Post by abjha1998 on Converting UINT into bytes and converting 2Bytes into UINT CODESYS Forge talk (Post)
Thank you for the reply. I got an error saying that MEM.PackBytesToWord(GVL.Actual_Speed_DUT_high,GVL.Actual_Speed_DUT_low) = u; is not a valid statement. Am I missing some library?
Last updated: 2023-12-08

Post by timvh on FB string and naming CODESYS Forge talk (Post)
Really not clear what you are trying to do, but isn't a Struct enough? So add an object of the type DUT to the Application. Then create a structure TYPE ST_Sensor : STRUCT sName : STRING; uiNumber : UINT; END_STRUCT END_TYPE Then in you application add an instance of this Structure stSensor1 : ST_Sensor := (sName := 'my sensor', uiNumber := 1); or use it like this stSensor1.sName := 'my sensor';
Last updated: 2024-09-28

Post by ph0010421 on How to create a stopwatch? CODESYS Forge talk (Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08

1 2 3 .. 170 > >> (Page 1 of 170)

Showing results of 4231

Sort by relevance or date