I am doing a SCADA project on temperature and humidity monitoring system. The customer requested that we store the database through codesys without the need for intermediary software such as MySQL, MSSQL,... and be able to export reports at selected times, reports exported to csv files. , xslm,... Can anyone help me?
When I load the SMC_GroupWait command twice in a row into the buffer an error occurs when I try to MC_MoveLinearRelative in the dynamic coordinate system. If I use MC_MoveLinearAbsolute in the dynamic coordinate system, it still works
Hi! I'm a newbie. I'm doing a project for Delta Robot using Codesys and got this error when trying to move in a dynamic coordinate system. This error occurs when I use FB MC_MoveLinearRelative and FB SMC_GroupWait
Hi! I'm a newbie. I'm doing a project for Delta Robot using Codesys and got this error when trying to move in a dynamic coordinate system. This error occurs when I use FB MC_MoveLinearRelative in PCS coordinate system
Hi Edwin I changed to Control RTE and It works now. But now I have another problem. I want to control Ethercat Multi-Axis Servo from Syntec Manufacturer. Codesys Library didn't support this kind of Drive yet. I have imported the ESI File of this Drive and tried to run it. But it has many error occur <Entry severity="error" component="IoDrvEtherCAT" user="nobody" timestamp="7/18/2023 8:42:30 AM" infoId="0">AL Status read from slave address 1002 status 16#1B : Sync manager watchdog</Entry> <Entry severity="error"...
Hi Edwin I changed to Control RTE and It works now. But now I have another problem. I want to control Ethercat Multi-Axis Servo from Syntec Manufacturer. Codesys Library didn't support this kind of Drive yet. I have imported the ESI File of this Drive and tried to run it. But it has many error occur <Entry severity="error" component="IoDrvEtherCAT" user="nobody" timestamp="7/18/2023 8:42:30 AM" infoId="0">AL Status read from slave address 1002 status 16#1B : Sync manager watchdog</Entry> <Entry severity="error"...
Hi Edwin. Let me change to Control RTE and inform you result
Hi Edwin. Thank for your prompt feedback But if I change to Control RTE. Do I need to change the hardware also? Currently I'm using the normal IPC for controller hardware
Hi Edwin. Thank for your prompt feedback But if I change to Control RTE. Do I need to change the hardware also? Currently I'm using the normal IPC for controller hardware
Hi Edwin I'm using -Codesys Control Win 3.5.8.40 on WIN10 -Network Adapter Intel(R) Ethernet Controller(3) I225-V for Ethercat Master. -Slave is Omron Ethercat G5 Servo Drive I also follow the tip https://forge.codesys.com/forge/talk/Engineering/thread/03af9426eb/ and Install WinPcap 4.1.3 I don't know where to modify CODESYSControl.cfg in Codesys Control Win 3.5.8.40 But it was not a success. I don't know what is the problem. Could you please check my problems? Best Regard
Hi Edwin I'm using -Codesys Control Win 3.5.8.40 on WIN10 -Network Adapter Intel(R) Ethernet Controller(3) I225-V for Ethercat Master. -Slave is Omron Ethercat G5 Servo Drive I also follow the tip https://forge.codesys.com/forge/talk/Engineering/thread/03af9426eb/ and Install WinPcap 4.1.3 I don't know where to modify CODESYSControl.cfg in Codesys Control Win 3.5.8.40 But it was not a success. I don't know what is the problem. Could you please check my problems?