  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Hi everyone, new at Codesys and PLC programming in general. I am using Codesys Win V3.5 SP20 I would like to measure an encoder's frequency output (obtaining that pulse train from Factory IO) and intended to use the MeasureFrequence FB (Intern/CAA/Utilities/CAA Mathematics/3.5.19.0). As mentioned in the title what I need to measure is low frequency, such as lower than 40hz (a cycle every 25mS) or so; I could even go lower frequency if required as this is for test purposes) therefore I am not expecting...

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Hi Eschwellinger, sorry for so late reply but I found a solution back then; uninstall completely Codesys V3x64 and re-installed Codesys V3x32 to properly note the password I created and everything went ok. thank you for your suggestion and have a good day/evening Mike

  • mp9876 mp9876 posted a comment on ticket #2

    Hello Ullrich, .package should have been obvious enough but I guess I missed that part somehow so I had not tried to unzip that compressed folder. Not a whole lot familiar with libraries as well so. Thank you very much for your time as I effectively found the required project file that way. Kind regards, Mike

  • mp9876 mp9876 created ticket #2

    Cannot locate Building Automation Examples.project

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Following up on the invalid user authentication on the target Not 100% sure what the problem was but following my post I managed to create an administrator level user. Then my next issue was that I could not connect to the device. I might have flipped the device from a 64 bit version to a 32 bit version so I did UPDATE DEVICE back to the 64 bit version; still could not connect somehow. Then I did two things at the same time that fixed my problem: Wiped the Codesys Control Win 64 bit version and installed...

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Yes it had been the case I believe as I have seen that message regarding they were not the same. I had update the device though to match them and that still did not fix the problem. I gotta say I wanted to get out of that situation and attempted a lot of things and then I did two things at the same time that fixed my problem: Wiped the 64 bit version and installed the 32 bit version Installed latest SP20 I wish I knew which one of these actions fixed the problem but now I gotta catch up on this IDE...

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Hi Automa, it seems the solution you were bringing up on 2022-04-06 could really help me as I did not remember the password I initially set. My problem though is that I am using Codesys Control Win V3.5 SP19/60 (64 bit) and I cannot locate any of the files you listed up there. I have been looking inside folder: C:\Program Files\CODESYS 3.5.19.60\CODESYS\ and they appear not to be present at all neither in the CODESYS folder or any sub-folders. Uninstalling and re-installing unfortunately does not...

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. β€˜Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh...

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Just adding some info regarding the issue above. Logged onto the project using dev3og5 user (see screenshots); appeared to be ok although when attempting to logon to the device message says 'currently not authorized to perform this operation on the device' (screenshot). If user dev3og5 has same permissions as Owner user; why would it not be authorized. I am at a loss; any assistance would greatly be appreciated. Thank you Mike

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Hi everyone, Had that problem before where I could not create another user but used the method just above and it worked great. My problem now is that I get this message when attempting to logon to the device: invalid user authentication on the target dev5, the new user created is pretty much a copy of the user 'Owner' except for the password. Any idea as to why I am always getting this "invalid user authetication on the target" message ? Using Codesys V3.5 SP19 Patch 6 + (64 bit) Regards

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    That definitely does the job with the Ladder Logic Diagram type; fully equipped toolbox. Just starting with Codesys and was following programming steps which explains the choice of ladder I had picked. Thanks for the tip and have a good one! Cheers!

  • mp9876 mp9876 posted a comment on discussion Engineering πŸ‡¬πŸ‡§

    Hello, I am attempting to get started here and bumping into this funny issue. I am using this version of CODESYS: ============================== DETAILED VERSION INFORMATION Created at 2024-03-10 ============================== Startup profile: ............................................................... CODESYS V3.5 SP19 Patch 6 OS version: .................................................................... Microsoft Windows NT 10.0.19045.0 .NET version: .....................................................................