Personal Data

Username:
pixsys
Joined:
2020-09-09 12:19:34
Location:
Italy / CET
Gender:
Male

Projects

  • No projects to display.

Skills

This is a list of skills that NicolaG_89 possesses:

  • Ladder Logic
  • Programming Language

User Activity

  • Modified a comment on discussion Visualization πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, please check if "Support client animations and overlay of native elements" option is enabled. This option is very heavy to manage for the Webclients. I'm using the Pixsys srl "TC series" HMI with the code "P3" (so a 4+4 cores CPU) that runs very well also with this option active. The same CPU is mounted also in their WebPanel "WP" series, so you can try one of them if you want.

  • Modified a comment on discussion Visualization πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, please check if "Support client animations and overlay of native elements" option is enabled. This option is very heavy to manage for the Webclients.

  • Posted a comment on discussion Visualization πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, please check if "Support client animations and overlay of native elements" option is enabled. This option is very heavy to manage for the Webclients.

  • Posted a comment on discussion Visualization πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, the option "Support client animations and overlay of native elements" needs a very powerful graphics accelerator in the system. I'm using the Pixsys srl "TC series" HMI with the code "P3" (so a 4+4 cores CPU) that runs very well also with this option active.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I'm using a Pixsys PL700 PLC (arm PLC based on BBB) on Codesys V3 and I'm trying to communicate with a custom CANopen device that has not EDS file. No problem with SDO, but what about PDO? The device has already some PDO mapped so I only need to use them, no need to configure them. Can somebody give me a suggestion? Thank you

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I need to use EoE, do I need some Routing/Tap etc configuration on the device?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I'm trying to communicate with a MoviconCE HMI to a codesys PLC. During Movicon Codesys driver configuration I can check the communication with the PLC and it seems Ok, I can also import the variable, reading it from the PLC (the edge gateway is correctly running on it), but when I run the Movicon Project into the HMI, I get "communication error 87" and my variable remains to "0". Using a x86 PC (my developing PC) and the same Movicon project I can read the variable correctly. So it seems that...

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    Ok verified, with "export" button Codesys creates a zip file with the GSD file inside. Thank you.

View All