Unable to connect to this device
CODESYS Forge
talk
(Thread)
Unable to connect to this device
Last updated: 2024-06-28
Cursor to move to a control
CODESYS Forge
talk
(Thread)
Cursor to move to a control
Last updated: 2025-08-12
VAR_IN_OUT, POINTER TO and REFERENCE TO
CODESYS Forge
talk
(Thread)
VAR_IN_OUT, POINTER TO and REFERENCE TO
Last updated: 2021-11-16
Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon
CODESYS Forge
talk
(Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20
Post by timvh on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
You can get the state by just using the name of your node (same name as in device tree): VAR etcState: IoDrvEthercatDriverLib.ETC_SLAVE_STATE; END_VAR etcState := EJ1100.wState; Alternatively, you can iterate through the device tree to get the status of all (Ethercat) nodes. See here an example (no guarantee it works, just give as suggestion): PROGRAM P_IO_State VAR CONSTANT uiMAX_NR_OF_TERMINALS : UINT := 100; END_VAR VAR // general device diagnosis // can only be used when the Device - PLC Settings - Advanced settings - enable diagnosis for devices is enabled // this will add the DED library coupler: DED.INode; terminal: DED.INode; aDeviceState: ARRAY[0..uiMAX_NR_OF_TERMINALS - 1] OF DED.DEVICE_STATE; uiTerminalCount : UINT; uiIndex : UINT; // for each terminal check if it implements device diagnostics xQueryResult: BOOL; itfDevice : DED.IDevice2; xDiagAvailable: BOOL; eError: DED.ERROR; xEverythingOK: BOOL; END_VAR uiTerminalCount := 0; // start at the top of the device tree with the first EtherCAT coupler coupler := EtherCAT_Master.FirstChildNode; WHILE coupler <> 0 DO // for each coupler that is found start at the first terminal terminal := coupler.FirstChildNode; WHILE terminal <> 0 AND uiTerminalCount < uiMAX_NR_OF_TERMINALS - 1 DO // for each terminal that is found get the status through the device diagnosis interface xQueryResult := __QUERYINTERFACE(terminal, itfDevice); IF xQueryResult THEN aDeviceState[uiTerminalCount] := itfDevice.GetDeviceState(xDiagnosisInfoAvailable => xDiagAvailable, eError => eError); uiTerminalCount := uiTerminalCount + 1; END_IF terminal := terminal.NextSiblingNode; END_WHILE coupler := coupler.NextSiblingNode; END_WHILE uiIndex := 0; xEverythingOK := TRUE; WHILE uiIndex < uiTerminalCount DO IF aDeviceState[uiIndex] <> DED.DEVICE_STATE.RUNNING THEN xEverythingOK := FALSE; EXIT; END_IF uiIndex := uiIndex + 1; END_WHILE
Last updated: 2025-02-06
Post by duvanmoreno24 on Modbus writing on value change
CODESYS Forge
talk
(Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03
How to allow a user to handle certificates without access to sourcecode?
CODESYS Forge
talk
(Thread)
How to allow a user to handle certificates without access to sourcecode?
Last updated: 2024-08-07
I want to convert a WORD to a hex string like 15.432 to '3C48'
CODESYS Forge
talk
(Thread)
I want to convert a WORD to a hex string like 15.432 to '3C48'
Last updated: 2024-04-19
how to add module to raspberry pi
CODESYS Forge
talk
(Thread)
how to add module to raspberry pi
Last updated: 2020-11-24
how to set custom from/to timestamp in Trend
CODESYS Forge
talk
(Thread)
how to set custom from/to timestamp in Trend
Last updated: 2020-03-31
Unable to connect to git remotes through Codesys.
CODESYS Forge
talk
(Thread)
Unable to connect to git remotes through Codesys.
Last updated: 2023-11-10
How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Thread)
How to adapt Codesys Control SL to custom board
Last updated: 2024-08-09
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-08-26
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-08-26
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-08-26
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-08-26
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-08-26
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-08-26
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-09-03
Unable to Connect to Modbus RTU Device
CODESYS Forge
talk
(Thread)
Unable to Connect to Modbus RTU Device
Last updated: 2024-09-04
How to revert to previous version library
CODESYS Forge
talk
(Thread)
How to revert to previous version library
Last updated: 2024-09-06
Unable to add alarm configuration object to project
CODESYS Forge
talk
(Thread)
Unable to add alarm configuration object to project
Last updated: 2024-09-27
Trying to connect Codesys OPC server to Ignition
CODESYS Forge
talk
(Thread)
Trying to connect Codesys OPC server to Ignition
Last updated: 2025-01-22
How to use libdoc to implement libraries in multiple languages
CODESYS Forge
talk
(Thread)
How to use libdoc to implement libraries in multiple languages
Last updated: 2025-03-13
Codesys 3.5.21 fails to copy file to USB
CODESYS Forge
talk
(Thread)
Codesys 3.5.21 fails to copy file to USB
Last updated: 2025-05-27
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.