[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3 CODESYS Forge talk (Thread)
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
Last updated: 2021-10-18

Codesys sales and support. Is it true that Codesys wants to get more customers? CODESYS Forge talk (Thread)
Codesys sales and support. Is it true that Codesys wants to get more customers?
Last updated: 2023-07-03

how to convert library from CodeSys 2.3 to CodeSys 3.x ? CODESYS Forge talk (Thread)
how to convert library from CodeSys 2.3 to CodeSys 3.x ?
Last updated: 2026-04-29

Post by dekelec on Codesys 2.3 & Peak PCAN CODESYS Forge talk (Post)
I use Peak USB adapter daily to download from CoDeSys 2.3 and 3.5 to IFM, EPEC and other controllers. The process: - First you need to install the appropriate driver. Link: https://www.peak-system.com/Drivers.523.0.html?&L=1 - Restart the computer - Start the CoDeSys application - Change the name of the adapter in Communication parameters, as mentioned in previous comment. Write the name exactly as written "Peak_USB", as it could also be case sensitive (defines which .dll file to use). If this doesn't work I would contact the vendor of the controller to find out the procedure. In the attachment I've added a FAQ document from IFM regarding using PCAN USB. P.S. I've noticed in your picture of communication parameters a channel via TCP/IP is mentioned. In this case a USB to CAN connection is not being used. First you should change the channel/gateway to connect via CANbus or connect using an Ethernet cable.
Last updated: 2024-07-09

Post by bschraud on Code erzeugen mit kryptischer Fehlermeldung mit GVL_Io_dd05d808 CODESYS Forge talk (Post)
Hallo, beim Codeerzeugen bekomme ich wiederholt Fehlermeldungen, bei denen nicht mit einem Klick in das betroffene Modul gewechselt werden kann. Die Fehlermeldung tritt allerdings nach "Gerät aktualisieren" nicht mehr auf. Wenn ich das Projekt speichere, Codesys schließe, anschließend Codesys wieder starte und Code erzeugen will, tritt der Fehler wieder auf: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] PAC: C0032: Typ 'Unbekannter Typ: 'ADR(GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7)'' kann nicht in Typ 'POINTER TO IoConfigParameter' konvertiert werden [FEHLER] PAC: C0077: Unbekannter Typ: 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' [FEHLER] PAC: C0046: Bezeichner 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' nicht definiert Kompilierung abgeschlossen -- 3 Fehler, 1 Warnungen Übersetzung abgeschlossen -- 3 Fehler, 1 Warnungen : Kein Download möglich Die Recherche nach der Bedeutung von "HPS_7" oder "GVL_Io_dd05d808" verlief leider ergebnislos. Ich habe nur einen ähnlich erscheinenden Thread gefunden, der aber nicht gelöst wurde: https://forge.codesys.com/forge/talk/Engineering/thread/0666dce94f/ Ich verwende Codesys 3.5 SP20 (64bit) mit CODESYS Control for Raspberry Pi MC SL 4.11.0.0. Alle anderen Geräte sowie die Projektumgebung sind frisch aktualisiert. Kennt jemand die Bedeutung dieser Fehler bzw. wie man sie beheben kann? Vielen Dank für die Hilfe
Last updated: 2024-05-16

Post by andrej on Signing of Boot Application for Raspberry Pi CODESYS Forge talk (Post)
Hello all, I would like to sign my boot application for my Raspberry PI. I generated the X509 Certificate and loaded it to the raspberry. It is successfully displayed as trusted certificate. However, I cannot download and start the Application to the Rasperry, due to a signature mismatch.The error message is rather clear, but I still don’t see how I can fix the issue, since the certificates on the Controller seem to mach the certificate in the user profile. Could you tell me where the error is or which step I am missing. Many thanks and kind regards Andreas
Last updated: 2025-07-17

Post by andrej on Signing of Boot Application for Raspberry Pi CODESYS Forge talk (Post)
Hello all, I would like to sign my boot application for my Raspberry PI. I generated the X509 Certificate and loaded it to the raspberry. It is successfully displayed as trusted certificate. However, I cannot download and start the Application to the Rasperry, due to a signature mismatch.The error message is rather clear, but I still don’t see how I can fix the issue, since the certificates on the Controller seem to mach the certificate in the user profile. Could you tell me where the error is or which step I am missing. Many thanks and kind regards Andreas
Last updated: 2025-07-17

Post by andrej on Signing of Boot Application for Raspberry Pi CODESYS Forge talk (Post)
Hello all, I would like to sign my boot application for my Raspberry PI. I generated the X509 Certificate and loaded it to the raspberry. It is successfully displayed as trusted certificate. However, I cannot download and start the Application to the Rasperry, due to a signature mismatch.The error message is rather clear, but I still don’t see how I can fix the issue, since the certificates on the Controller seem to mach the certificate in the user profile. Could you tell me where the error is or which step I am missing. Many thanks and kind regards Andreas
Last updated: 2025-07-17

Post by nmcc on Viewing PDF in WebBrowser Visual Element CODESYS Forge talk (Post)
I am trying to show a PDF in a WebBrowser element. I have the file saved to the drive of the HMI/PLC. I am linking it in the URL parameter of the WebBrowser using the following directory link. 'http://localhost:8080/$$sdcard$$/FileName.pdf'. This allows for the program to download without any errors. When I navigate to that screen it is just a white box and nothing shows. I attempted putting the same link in the show parameter and I get a loading icon on my cursor when monitoring the HMI with my PC. Any help is appreciated. Thank you.
Last updated: 2024-02-29

Post by comingback4u on Memory Address Overlap CODESYS Forge talk (Post)
Hello, We use a controller that comes with a bunch of predefined faults. These faults are considered active and historic. They are a 32 byte array but only take up 26 bytes of data. Because of this the historic faults start at address 26 instead of 31. Active faults variable take up address location 0 to 31. Historic faults variable take up address location 26 to 57. Because of this overlap I get an error that these overlap and it wont allow me to download to my controller. This isn't an issue in 3.5.5.4 but becomes an issue in newer version. Is there a way to turn this off? If I change the address location, the historic faults then become broken without doing some manipulation in the code. The software will build just fine. Thank you for your time.
Last updated: 2024-03-07

Post by pernockham on Images not shown in webvisu CODESYS Forge talk (Post)
Two issues. Ive been struggling to get the user management the way I want it. I want to protect the device from unauthorized upload/download, but I do not want login requirement on webvisu. The combination that seems to work is to use "runtime device user management" while keeping the visu user management in "legacy mode"? Initially this seemed to work, but now images are not loaded when using direct access, while they are still shown if I access the webpage via Automation server. Im guessing its connected to the authorization changes? Anyone able to help out? Thanks Also, I read that legacy mode should be avoided, is it possible to use "runtime based visu user management" while keeping direct access to the webpage without login. System is a "Control for linux SL, version 4.20.0.0" Per
Last updated: 2026-04-10

Post by reinier-geers on internal error CODESYS Forge talk (Post)
Hi ive got an internal error. BUt no solution for this. How do i solve this ? ------ Build started: Application: Slave_3.Application ------- [ERROR] Internal error:System.NullReferenceException: De objectverwijzing is niet op een exemplaar van een object ingesteld. bij _3S.CoDeSys.ObjectManager.ExistingPSNode.get_ParentObjectGuid() bij _3S.CoDeSys.ObjectManager.AbstractPSNode.get_ParentNode() bij _3S.CoDeSys.ObjectManager.ProjectStructure.ConsolidateAndClearPendingChanges(LList`1 pendingChanges) bij _3S.CoDeSys.ObjectManager.ProjectStructure.RaisePendingChanges(Boolean bTriggerPendingChanges2) bij _3S.CoDeSys.ObjectManager.Project.HandleUndoMgrAfterEndCompoundAction2(EventArgs e) bij _3S.CoDeSys.ObjectManager.UndoManager.OnAfterEndCompoundAction2(EventArgs e) bij _3S.CoDeSys.ObjectManager.UndoManager.EndCompoundAction() bij _3S.CoDeSys.DeviceEditorSoftMotion.StaticSoftMotionEditor._ehBeforeCompile(Object sender, CompileEventArgs e) bij _3S.CoDeSys.Core.LanguageModel.CompileEventHandler.Invoke(Object sender, CompileEventArgs e) bij _3S.CoDeSys.Core.LanguageModel.CompileEventHandler.Invoke(Object sender, CompileEventArgs e) bij _3S.CoDeSys.LanguageModelManager.LanguageModelManagerConsolidated.OnBeforeCompile(CompileEventArgs e) bij _3S.CoDeSys.LanguageModelManager.LanguageModelManagerConsolidated.RaiseAndCheckBeforeCompile(Guid guidApplication, IMessageCategory cmc) bij ..(Boolean , Boolean , Boolean ) bij _3S.CoDeSys.Compiler35210.CompilerPhases.CompilerPhaseControllerGenerateCode.(Boolean ) bij _3S.CoDeSys.Compiler35210.CompilerPhases.CompilerPhaseControllerGenerateCode.() Build complete -- 1 errors, 0 warnings : No download possible
Last updated: 2026-04-14

Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200 CODESYS Forge talk (Post)
Turns out I managed to get a connection to my PLC. It seems that a few weeks ago Wago released something with version 4.3.3(25). So I reset my PLC to Factory-Reset, set it to the 192.168.1.17 IP and changed the IP to the one I wanted with the Wago EthernetSettings tool. Then updated the latest firmware using the WAGOupload tool. Now the PLC came back up without a PLC runtime running, so in the Web-tool I wen't to the "Configuration"/"PLC Runtime" and selected the runtime version "CODESYS V3". I uninstalled all Codesys versions and installed the version from the download package of Wago together with all the packages the bundle provided. After creating a new project I didn't select the old PFC200 runtime, but one of the dozens of new device profiles, that it now listed. With these settings I was then able to connect to my PLC. Now I hope I'll get the existing project that I had ported to this new structure. Sorry for the noise. Chris
Last updated: 2023-08-26