Search talk: set two element at a time

 
<< < 1 .. 106 107 108 109 110 .. 182 > >> (Page 108 of 182)

Post by apurv on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
okay but will this pass the array by copying it or it will be a reference to original array only.
Last updated: 2024-01-09

Post by reinier-geers on Pointer Axis CODESYS Forge talk (Post)
I want to make a FB of MC. But i need a variable for Axis. How do i have to declare that ? ptAxe : AXIS_Ref_SM3; //:= SM_Drive_ETC_Delta_ASDA_A2 ; this is somehowe a problem
Last updated: 2024-01-12

Post by nksr on Is using 'en-gb' and 'en-GB' in visuelems.currentlangauge the same? CODESYS Forge talk (Post)
I am currently programming a language switch program. So, the text flickers between 'en-gb' and 'en-GB' in visuelems.currentlangauge and even if I put a breakpoint, it still flickers. Can you please suggest a solution? Thanks
Last updated: 2024-01-31

Post by davidbo on Does CODESYS use its own native driver for I2c? CODESYS Forge talk (Post)
CODESYS Control for Raspberry Pi MC Does CODESYS use its own native driver for I2c? I have a python script communicating with a device simultaneously with a CODESYS doing the same. The bus is not saturated. But I get many read errors
Last updated: 2024-02-13

Post by davidbo on I want to convert a WORD to a hex string like 15.432 to '3C48' CODESYS Forge talk (Post)
I try with BYTE_TO_HEXinASCII but I cant get it right. How do I convert a word value like 15432 to the HEX text string '3C48'
Last updated: 2024-04-19

Post by stulle on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
Hello everyone, I have a problem. Codesys 3.5 P19 works without any problems. However, P20 is not usable, after starting it hangs "no response". A new installation didn't help either, unfortunately I can't find a more precise error. BR
Last updated: 2024-04-21

Post by davidbo on How to stay in a method until something is finished. CODESYS Forge talk (Post)
You never stay in a method. You need a block to do that. Something like: VAR button:BOOL:=FALSE; count:UINT:=0; END_VAR IF button THEN //read pressure count:=count+1; IF count>1 THEN button:=FALSE; count:=0; END_IF END_IF
Last updated: 2025-11-04

Post by tristan on Textfield display problem CODESYS Forge talk (Post)
Hello everyone, I have a little problem with textfield display. When I put a solid backgroud, no problem. But when I put it to invisible, some strange things appears with the text. Do you have this kind of issues ? Thanks a lot, Tristan
Last updated: 2025-11-20

Post by reinier-geers on SYSDIR 3.5.17.0 CODESYS Forge talk (Post)
I had a funcioning Directory read wit SYSDIR. Now ive got a new controller with Linux. and now i get only ordners Names. NO file Names !! WHY ? It workt already on a other with linux. But that was i think version 14
Last updated: 2026-01-06

Post by reinier-geers on SYSDIR 3.5.17.0 CODESYS Forge talk (Post)
I had a funcioning Directory read wit SYSDIR. Now ive got a new controller with Linux. and now i get only ordners Names. NO file Names !! WHY ? It workt already on a other with linux. But that was i think version 14
Last updated: 2026-01-06

Post by mikek10 on HTTP Client TCP Init Error CODESYS Forge talk (Post)
Hi, I tried posting in the discussion for the HTTP Client example but perhaps that is not monitored? I have been using http client successfully for approximately 12 months, however in recent weeks I have begun to get TCP_INIT_ERROR when attempting to communicate. The only resolution seems to be power cycling and then the connection begins to work again for a time. I am not aware of any changes to code or libraries between working ok and now. Cold reset does not resolve, only power cycle. It seems the error from NBS.TCP_Client is 6002 which I think is invalid_addr However the address is the same when working and not working?
Last updated: 2024-07-04

Post by vernon-laurence on EtherCAT fieldbus CODESYS Forge talk (Post)
The simplest way to do this would be to add a bus coupler dedicated to the expansion IO. The EtherCAT network does not fault when modules connected to the expander are not present. In the image below, nothing below the red line is present in the network - with the network working correctly. In your "base" project, simply include all of the possible modules, and then plug them in as you add pumps to the system. I would also highly recommend against the use of direct addressing. There are other methods to accomplish this, including using the "Optional" checkbox for modules and explicitly addressing them. Although, this would require more upfront work to design the network, and some additional work each time modules were added. https://content.helpme-codesys.com/en/CODESYS%20EtherCAT/_ecat_edt_slave_slave.html
Last updated: 2024-04-09

Post by danwoodlock on Rpi zero w lost license after 4.11 update CODESYS Forge talk (Post)
Hello all, Encountered an issue with my zero which seems to have happened after the 4.11 update. It now runs in demo mode (2hr) and I am trying to see what the appropriate steps are prior to contacting codesys directly. Background: I recently did a fresh install of w11 on my pc, so it seems "c:\ProgramData\CODESYS\Licenses\" only has information related to my pi5, which I licensed just this past Friday. I have all my license documentation about my rpi zero as far as the emails received, but when I try to claim using the ticket number it says its already been used, or something to that effect, which it was. Currently trying to perform device license reader, which is taking some time.
Last updated: 2024-04-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by julianramirez on Visu 4.9.1 auto-logon/login CODESYS Forge talk (Post)
Hello everyone, I have been trying to test the auto-login feature that is advertised on the Release Notes since Visu 4.8: *Version: 4.8.0.0 Besides some bug fixes and improvements this version contains the following new functionality: Alarmmanagement: Possibility to raise alarms programmatically Use real time clock of IEC context Automatic login for WebVisu using Chrome "Sign in automatically"* I am using a personalized login Visualization, the User Management works, however, when ticking the checkbox that keeps the credentials stored, after I reload the page I still see that the user and password details are not filled in. I tried with the default Login Visu (Blue one), and still see the same behavior - VisuUserManagement.VUM_LoginVisualization - I've tried with Chrome and Edge. Thanks for your help
Last updated: 2026-01-12

Post by herbasso88 on WebVisu flickering CODESYS Forge talk (Post)
Good morning, I'm new on Codesys Forge, so I'm not sure if this is the right place to talk about my problem. When I open my WebVisu pages with Microsoft Edge, or Chrome, the background and also some rectangles blinking without reason!!! The application is developed with Codesys 3.5.17.10 and run on Codesys HMI, same version (3.5.17.10). After several experiments I discover that the problem happens when I made dynamic the "End of area" property of a meter object, but I can't understand why this blinking problem happens. Also, the problem is only at the WebVisu page, the "normal" VISU pages (the ones opened when Codesys HMI start) work always perfectly. Another strange thing is that the problem happens only if on the same page, where there is the meter object, there is also a trend object!?!? Codesys HMI is running on a Virtual Machine (VMware Workstation 15 player, v.15.5.6) running Windows 10 Pro N 64-bit. The blinking problem happen also if I convert the project to Codesys 3.5.20.0. This version of Codesys and Codesys HMI are installed on a Virtual Machine running Windows Server 2019 Standard 64-bit. In attachment the archive of my project. The attached project has only one page, if "Enable Counter" is not pressed the "End of area" variable of the meter is not updated in the software, and everything work well, normal VISU and WebVisu; if "Enable Counter" is pressed, the "End of area" variable of the meter is updated in the software, and the WebVisu page start blinking. I tried also to enable the "Support client animations and overlay..." property at VisualizationManager, this seems stop the blinking problem, but that property also destroy my WebPage, moving almost all the graphical object, that also seem not working anymore. I really need help to understand what I'm doing wrong, I have to develop a bigger project and I have to understand if trend objects and animated meters cannot stay in the same page. In the final project the WebVisu will be very important because the customer will use this way to access the application to monitor the process. Regards
Last updated: 2024-05-06

Post by bertus on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Hello all, I am trying to run a XY trajectory from a static G-Code file. Everything works except the smoothing/blending of the corners. My setup: Codesys v3.5sp18 Raspberry Pi 4 CODESYS Control for Raspberry Pi SL, using demo license. Zero axes (only using the interpolator). The order of processing for my decoding is: SMC_NCDecoder (ok) SMC_SmoothMerge (ok) SMC_SmoothPath (not ok) SMC_LimitDynamics SMC_CheckVelocities I created following instances and buffers: fbNCDecoder: SMC_NCDecoder; fbSmoothMerge: SMC_SmoothMerge; fbSmoothPath: SMC_SmoothPath; fbLimitDynamics: SMC_LimitDynamics; fbCheckVelocities: SMC_CheckVelocities; aNCDecoderBuffer: ARRAY[0..49] OF SMC_GeoInfo; // buffer stage 1 (fbNCDecoder) aSmoothMergeBuffer: ARRAY[0..19] OF SMC_GeoInfo; // buffer stage 2 (fbSmoothMerge) aSmoothPathBuffer: ARRAY[0..99] OF SMC_GeoInfo; // buffer stage 3 (fbSmoothPath) aLimitDynamicsBuffer: ARRAY[0..39] OF SMC_GeoInfo; // buffer stage 4 (fbLimitDynamics) My original G-Code file has a lot of short G1 elements but this example, I reduced it to a simple square: N000 G51 D10 N010 G38 O1 N020 G00 X0 Y0 F50 E1000 E-1000 N030 G01 X0 Y-37.5 N040 G01 X-75 Y-37.5 N050 G01 X-75 Y37.5 N060 G01 X0 Y37.5 N070 G01 X0 Y0 N080 G50 N090 G39 O1 In the Codesys CNC settings, I have these instances activated: SMC_SmoothMerge SMC_SmoothPath SMC_LimitDynamics SMC_CheckVelocities And with those settings (and the path-preprocessing button actived), the G-Code viewer shows the square with nicely blended corners (see attached picture). However, when running it on the PLC, it doesn't blend the corners at all. Below the relevant part of my code. The process is started with bDecode. // stage 1: decoding G-code fbNCDecoder( ncprog := square, bExecute:= bDecode, bAbort:= NOT bDecode, nSizeOutQueue := SIZEOF(aNCDecoderBuffer), pbyBufferOutQueue := ADR(aNCDecoderBuffer) ); // stage 2: merge short linear segments fbSmoothMerge( bExecute := bDecode, poqDataIn := fbNCDecoder.poqDataOut, nSizeOutQueue := SIZEOF(aSmoothMergeBuffer), pbyBufferOutQueue := ADR(aSmoothMergeBuffer), piMaxDifference := PI_MAX_DIFFERENCE, usiMaxDegree := 5, wFeatureFlag := 1, wAdditionalParamNumber := 0, dMinimumCurvatureRadius := D_MIN_CURVATURE_RADIUS ); // stage 3: smooth corners fbSmoothPath( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothMerge.poqDataOut, eMode := SMC_SMOOTHPATHMODE.SP_SPLINE5_MIN_CURVATURE, eAddAxMode := SMC_SMOOTHPATHADDAXMODE.SPAA_NONE, nSizeOutQueue := SIZEOF(aSmoothPathBuffer), pbyBufferOutQueue := ADR(aSmoothPathBuffer), dAngleTol := D_ANGLE_TOL, bSymmetricalDistances := TRUE, bImprovedSymmetricCuts := TRUE ); // stage 4: keep acc/dec and velocity within limits fbLimitDynamics( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbSmoothPath.poqDataOut, wAxis := 16#07, nSizeOutQueue := SIZEOF(aLimitDynamicsBuffer), pbyBufferOutQueue := ADR(aLimitDynamicsBuffer), bIncludePathSettings := TRUE, dMaxVel := 2500, dMaxAccDec := 10000 ); // stage 5: check the path speed fbCheckVelocities( bExecute := bDecode, bAbort := NOT bDecode, poqDataIn := fbLimitDynamics.poqDataOut, dAngleTol := D_ANGLE_TOL); pathQueue := fbCheckVelocities.poqDataOut; // repeat until MaxDuration ... Any idea what I'm doing wrong? Is smooth path supposed to work at all when using a demo license? Thanks.
Last updated: 2025-12-17

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
This explanation aligns with the issues we’re experiencing with our machines. The scenario I described is happening with one of them (let’s call it Machine A). This machine is identical to another one (Machine B), except for some custom code that facilitates communication with an external Beckhoff PLC for MES integration in the production line. Machine B has been powered on and off daily for at least three months and has never had this problem. Given that, I highly doubt the MES custom code is the cause of the code corruption. This being said, your explanation does seem plausible. However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task?
Last updated: 2024-10-03

Post by imdatatas on Read "Homed" status from EtherCAT drive CODESYS Forge talk (Post)
Hello, I have experienced such situations with some servo drive devices in the past. The home completion information is reported to the upper controller by the slave drive with the states of the relevant bits in the StatusWord (for example; 6041h Bit10, Bit12 in Home mode). If the states of these bits are correct in terms of number and state but the motor does not actually perform the action; You can contact the slave drive manufacturer. There may be a problem with the device firmware. Another area you can play around with is looking at the settings in the "Advanced configuration" for Softmotion axis on the page the link to below, and trying it out and using the one that works for you. https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cmd_add_softmotion_cia402_axis.html A method I recommended worked for a user as in below message. https://forge.codesys.com/forge/talk/Engineering/thread/40bc82454d/ I hope your problem will be solved as soon as possible and by sharing the result here, you will help others to know and overcome it. Good luck. Best regards, Imdat
Last updated: 2025-01-08

Post by abuckie on i2c master not running CODESYS Forge talk (Post)
Hello, I am trying to create an Ethernet/IP device that can read analog signals, do some basic logic on it and then hand communicate the results to an Ethernet/IP master. I am using the Raspberry Pi to experiment with this as I would ultimately like to drive a display as well. I have loaded up the runtime on the Pi and got the digital I/O working. I have an ADS1115 ADC to I2C board and I can't get it to work, I get a message telling me the i2c master is not running and I am not sure where to start with this. Is there a manual for running CODESYS on the Pi or something like that I am missing? I found this post and opening the project in CODESYS V3.5 SP21 it seems like tons of this wouldn't convert properly https://forge.codesys.com/forge/talk/Runtime/thread/f1400b71b6/ I have added in the library and device manually and copied the structured text program but lost at what to do if the core functionality of the master is not running. I appreciate any help, thanks.
Last updated: 2025-05-19

<< < 1 .. 106 107 108 109 110 .. 182 > >> (Page 108 of 182)