Post by yofi on Raspberry PI change tag only responds after stopping PLC CODESYS Forge talk (Post)
Using V19 Patch 7 and 4.11.0.0 for Pi 4 Model B, My problem is whenever I change a tag e.g bool from true to false it will change in software but the pin will only go high to low after pressing stop PLC in codesys and same if i want to bring it back to high, have to login start plc change it and stop plc in order to change. any insight ? thanks
Last updated: 2024-05-25

Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys CODESYS Forge talk (Thread)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
Last updated: 2024-06-03

Post by nano on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
i know, this is the reason for us either. PLC-Handler is to big, and only available with additional Contracts/Costs. OPC-UA is to slow for us. As described, there is a solution available, but im not allowed to post them here. i would prefer you send a message at codesys store by "have a question" or similar called. Not sure. Or, if an Codesys-Official Member allows to share that informations, i can give you the right hints.
Last updated: 2024-06-15

Post by ranadheer on Request to share documents about SoftPLC Extension SL CODESYS Forge talk (Post)
Hello Everyone Our team is planning to begin an industrial automation project and we are currently evaluating the use of SoftPLC Extension SL as a potential solution. As we are in the early stages and have yet to start the implementation, we kindly request access to official reference documents, technical manuals, and datasheets relating to SoftPLC Extension SL. Thank you very much for your assistance. We look forward to your response.
Last updated: 2025-10-18

Post by rossanoparis on CAN TX regression in Control for Raspberry Pi 4.21.0.0 with CAN API library (RX works, TX silently fails) CODESYS Forge talk (Post)
Environment: Target: Revolution Pi (Kunbus RevPi), armv7l 32-bit OS: Raspbian GNU/Linux 9 (Stretch), kernel 4.19.95-rt38-v7 (SMP PREEMPT RT, built 2022-03-22) CAN: via SocketCAN (can0) Runtime: CODESYS Control for Raspberry Pi SL IDE: CODESYS V3.5 SP22 + patch 3 (previously V3.5 SP22 + patch 2, where everything worked with runtime 4.18.0.0) Library: CANBusAPI from the "CAN API" package, version 1.0.0.3 Summary: The setup worked correctly with V3.5 SP22 + patch 2 and runtime 4.18.0.0. After updating the IDE to SP22 + patch 3 and the runtime to 4.21.0.0, CAN transmission via the CANBusAPI library stopped working. Reception is unaffected. There are no error indications anywhere: the application runs normally and the CAN diagnosis reports a healthy bus. Systematic testing (below) shows the problem follows the runtime version, not the IDE update. Regression isolation: The same application (compiled under SP22 + patch 3, unchanged between tests) was downloaded to the same target with different runtime versions, changing only the runtime each time: 4.18.0.0: TX and RX both work 4.19.0.0: TX and RX both work 4.20.0.0: TX and RX both work 4.21.0.0: RX works, TX does not The behavior is fully reproducible in both directions (downgrading to 4.20 restores TX, upgrading to 4.21 breaks it again). Hardware, wiring, OS, project, and application code are identical across all tests. Diagnostic data (CANBusDiagnosis FB, while the application is transmitting on 4.21): ctSendCounter: incrementing normally ctTxErrorCounter: 0 ctRxErrorCounter: 0 eState: ERROR_FREE xBusAlarm: FALSE So the library accepts and counts the outgoing messages, no TX errors are reported, and the CAN controller state stays error-free, but the messages never reach the other nodes on the bus. Expected behavior: Messages sent via CANBusAPI (CANDriver / SendMessage) are transmitted on the bus, as with runtime versions up to and including 4.20.0.0. Notes: I am aware that the CAN API package (1.0.0.3, from 2016) is old; however, the regression is tied to the runtime version, since the identical binary works on 4.18-4.20. Questions: Is there a known change in CmpSocketCanDrv / CmpCAACanL2 between 4.20.0.0 and 4.21.0.0 that could affect TX via the CAN API library? Is runtime 4.21.0.0 still supported on Debian 9 Stretch (kernel 4.19, RT-patched), or is a newer OS required? If a minimum OS/kernel requirement was introduced with 4.21, is it documented?
Last updated: 2026-08-17

Post by struccc on Wish: CODESYSControl.cfg - again CODESYS Forge talk (Post)
Before creating this topic, I was browsing the search results for CodesysControl.cfg - many results, and I remember very well, it's a problematic issue for a long time. To summarize: there were many requests for documentation on this file - the most comprehensive reply is: https://forge.codesys.com/forge/talk/Runtime/thread/ebbf851a3d/#eb85 Hi, not really, this is covered by the manual which you get if you use a runtime toolkit which is not free of charge. Maybe we need to extract the config file part from that documentation if that is possible. BR Edwin I am not sure how much is this relevant, since we buy SL License directly from CODESYS... I think it is a reasonable demand, to get documentation on the configuration entries affecting the documented behaviour of the runtime system and it's components The actual reason I bring up this issue again can be read here: https://forge.codesys.com/forge/talk/Runtime/thread/febad3cc40/#0e12 but mostly my frustration about noticing some new, unknown and undocumented entries in my configuration file. Again. And this happens a lot recently. Just some examples: Changes with SysFile - and mandatory use of IEC path Introduction of Mandatory user management File transfer service now disabled by default SysProcess - allowed commands The above mentioned CmpApp parameters... And finally (Regaridng windows install): With the newer versions, the installation directory (together with the configuration file) tends to hide itself to some super silly location under the roaming profile data of local system account. I am not sure if this change was documented somewhere, but was a very unpleasant one. Someone could please explain the reason and the concept of the introduction of this release specific directories (I am sure, there is a good reason) - how to use them properly? - How to re-introduce user configuration (to preserve configuration data between versions)? - How to do version - to version migrations properly? - How to keep old version of runtime available and ready to start with it's original configuration and application? - ... Therefore, the lack a regularly updated description of CodesysControl .cfg , including all the configuration entries, together with their default values for different runtime versions is really a big deficiency.* This should be done for all components storing or just seeking data from this file... (Maybe there is such thing but I failed to find???) It is regularly causing trouble when introducing a new version (together with the long awaited bug fixes and enhancements), what has changed it's default behaviour for security or other practical reasons. I agree this is very important, and it is logical to change the default options: But it must be documented historically, and make it easily available, so we can prepare better for the upgrade of the runtime. Forge talk is a great source, but not very practical for this kind of documentation purposes... Thanks in advance for CODESYS staff πŸ™πŸ™πŸ™ (Ps.: It would look rather silly, if some members of the user community prepares this documentation on a Forge Wiki page... Or??? Should we?)
Last updated: 2024-11-21

Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win CODESYS Forge talk (Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04

Post by solve-it on SysFileOpenAsync CODESYS Forge talk (Post)
Just realized that it is the /dev/input/js0 file. Don't think this is a prob either. Found the ConfigFile. Where and how to add /dev/input/js0? raspberry [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 [SysTarget] TargetVersionMask=0 TargetVersionCompatibilityMask=0xFFFF0000 [CmpLog] Logger.0.Name=/tmp/codesyscontrol.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=1000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC [CmpSettings] FileReference.0=SysFileMap.cfg, SysFileMap FileReference.1=/etc/CODESYSControl_User.cfg [SysExcept] Linux.DisableFpuOverflowException=1 Linux.DisableFpuUnderflowException=1 Linux.DisableFpuInvalidOperationException=1 [CmpWebServer] ConnectionType=0 [CmpOpenSSL] WebServer.Cert=server.cer WebServer.PrivateKey=server.key WebServer.CipherList=HIGH [SysMem] Linux.Memlock=0 [CmpCodeMeter] InitLicenseFile.0=3SLicense.wbb [SysEthernet] Linux.ProtocolFilter=3 [CmpSchedule] ProcessorLoad.Enable=1 ProcessorLoad.Maximum=95 ProcessorLoad.Interval=5000 DisableOmittedCycleWatchdog=1 [CmpUserMgr] AsymmetricAuthKey=6873d655ac1f166f3743feea42d2f3dd1b39ae40 [CmpSecureChannel] CertificateHash=09fd8d52be4ddd45a709bc9c95e2aa093b3f5695 [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpMask=1 ;raspberry [ComponentManager] ;Component.1=CmpGateway ;Component.2=CmpGwCommDrvTcp ;Component.3=CmpGwCommDrvShm [SysCom] ;Linux.Devicefile=/dev/ttyS [CmpBlkDrvCom] ;Com.0.Name=MyCom ;Com.0.Baudrate=115200 ;Com.0.Port=3 ;Com.0.EnableAutoAddressing=1 [SysProcess] Command.0=shutdown [CmpApp] Bootproject.RetainMismatch.Init=1 ;Application.1=Application ;Application.1=Application ;Application.1=Application Application.1=Application [CmpRasPi] Architecture=armv6l [CmpRedundancyConnectionIP] [CmpRedundancy] [CmpSrv] [IoDrvEtherCAT]
Last updated: 2024-07-16

Post by aseitzinger on CODESYS Control for Linux SL on virtual machine? CODESYS Forge talk (Post)
Hello, there in different information available regarding the possibility to run CODESYS Control for Linux SL on a virtual machine. https://forge.codesys.com/trg/linux-sl/home/Home/ says CODESYS Control for Linux SL is a runtime system, which can run on any Debian based X86 PC, VM or Cloud container... https://store.codesys.com/media/n98_media_assets/files/2302000005/3/CODESYS%20Control%20for%20Linux%20SL_de.pdf says CODESYS Control for Linux SL can not be used on virtual hardware Currently I run the package mentioned on a virtualized debian machine running in PROXMOX Virtual Environment 7.4-17 and apart from huge jitter it runs without problems. The CODESYS key is passed as a USB defice to the VM. I wonder why there are different statements regarding the suitability in virtual machines and if the jitter would be reduced by installing CODESYS runtime on the host installing CDS runtime on the host and using a preemptive kernel (if available for the PROXMOX installation leaving CDS runtime where it is (on the virtualized debian machine) and install a preemptive kernel on the host and on the guest... Any advice is appreciated. Greets Arno
Last updated: 2024-01-08

Post by risele on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
First, if you don't need to change conversion rules in runtime, take a look at "Unit conversion" module (Application -> add object -> UnitConversion). You can specify there biderectional conversion with different units, limits and so on. Second, since MODBUS don't have "real" types but only general 16-bit registers and Real is 32-bit, generally you need a byte-was conversion Real <> two Words. Note, that depending on the devices on both sides, there are two options: Real-> Word1, Word2 or Real-> Word2, Word1, where Word1 is minor register in Modbus register pair and Word2 is major. You can use simple union: TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE and convert it as following: VAR myUnion:u_Real; rValue_TO_SEND:REAL; rValue_TO_GET:REAL; END_VAR myUnion.rVal:=rValue_TO_SEND; rValue_TO_GET:=myUnion.rVal; Note, that WORD-order should be properly set in MODBUS registers, otherwise you will get strange values. This tool is helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/ Alternative, you can use functions as REAL_TO_DW and DW_TO_REAL from OSCAT_BASIC, for example.
Last updated: 2026-02-19