Post by kaotic2499 on Upgraded Raspberry 2b to Raspberry 5, Trends Broken? CODESYS Forge talk (Post)
There is currently a bug with the Raspberry Pi 64 SL where it is unable to Trend Global Retain or PersistantVars. The work around is to use standard Global Variables for Trend Data. This will be patched by Codesys in the near future reference "VIS-6170"
Last updated: 2025-11-13

Post by timvh on CANbus issue CODESYS Forge talk (Post)
On a PC with the Control Win, this is probably related to the fact that the CAN drivers are not loaded. Go to the folder where your Control Win Configuration file is: - E.g. C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE - Open the CODESYSControl.cfg - Remove the semi-colon in front of the CAN driver you want to use (section ComponentManager). - Set the component ID to the next number in the list (e.g. Component.8) - Save this file and restart the Control Win.
Last updated: 2023-09-14

Post by timvh on Device logon problem following fresh install CODESYS Forge talk (Post)
In your project you selected the "CODESYS Control Win V3" as device, but the device you want to connect to is a "CODESYS Control Win V3 x64". Those are not the same. If you double click on the device during the network scan, you will get information that these are not the same, but that you can change the type in your project to the x64 bit type. Another option is to "right-click" on the device in the device tree of your project and select "update device" then select the x64 type.
Last updated: 2024-03-19

Post by timvh on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Post)
I'm not really sure what you are trying to do, but maybe you are referring to using the CmpCharDevice library? When you "open" the connection to a device, you can pass flags. What helped me is to set the non-blocking flag. I'm not sure if this is what you are referring to, but maybe it helps: dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice := CmpCharDevice.CDOpen(szFilename, dFlags, Result);
Last updated: 2023-09-20

Post by trusty-squire on How to adapt Codesys Control SL to custom board CODESYS Forge talk (Post)
For general usage, these links might help you out. If you are looking at using I2C interfaces, examples from the Raspberry Pi will probably be useful, even if your board isn't a Raspberry Pi. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_rts_serial_com.html https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_raspberry.html If you're developing your own drivers, I can't help you there, although the link you provided will help. If you drill in deeper, the I2C page for example shows function block and method usage, etc. Good luck!
Last updated: 2024-08-09

Post by shawn-plc on Return value from a tag given a string literal CODESYS Forge talk (Post)
Good afternoon everyone, I am looking for a way to return a value given a string tag path. I put together a pseudo-example to illustrate my use-case and was wondering if anyone in this forum can help. The function fnValueFromTagPath is the function I am looking to either create or use from existing library. I would greatly appreciate it. Please see the attachment for additional detail. -Shawn
Last updated: 2024-08-13

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
For small project, I would like to use my industrial computer as a PLC + Industrial Computer. Like that I can save the cost of one PLC. That why I am using Codesys on Linux. With the nic it is not working. I already set the IP adress with /etc/network/interfaces. Can it comes from there ? looking to "Control Linux SL" docuemntation it should work with rtu.
Last updated: 2024-10-23

Post by dkugler on Beckhoff EL6652-0010 with Codesys CODESYS Forge talk (Post)
we use successful for many years the KEB MFI terminal for Profinet, EtherCAT, Ethernet/IP,... You'll need a EtherCAT Coupler as "head" from KEB, Kendrion or Berghof. It's all the same board inside: https://www.kebamerica.com/products/ethercat-bus-coupler/ Or the coupler with 16Di/Do integrated: https://www.kebamerica.com/products/ethercat-digital-io-module/ last year I got a EK1100 with EL6731 Profibus treminal runnig. But it was a lot of reverse engineering and thinkering in Codesys and TwinCAT to be done, to get it up, fulfilling my needs. Good luck!
Last updated: 2025-03-25

Post by imdatatas on MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl [ERROR] CODESYS Forge talk (Post)
Hello everyone, Updating and converting an existing working Codesys Softmotion axis control project to the latest Codesys IDE and Softmotion version always gives the following error message during compilation. " [ERROR] sm3_basic, 4.18.0.0 (codesys): MC_MoveAbsolute: C0138: No matching 'FB_Init' method found for instantiation of SMC_MoveAbsRelPerformerImpl " -- Previously working version: Codesys IDE SP18.50, Softmotion 4.10.0.0 -- Later updated version with the error: Codesys IDE SP21.10, Softmotion 4.18.0.0 Has anyone encountered a similar issue? How can this be resolved? Regards, Imdat
Last updated: 2025-07-24

Post by pernockham on Engineering IDE from linux? CODESYS Forge talk (Post)
An update note. Still using linux/Qemu. Still happy, but sometimes some things are harder. I lost the "bridge" connection to my VM (meaning for instance I couldnt "scan network" and find local units. Have spent tons of hours to find out why. Finally it seems the traffic got blocked by the firewall/iptables so needed to set rules for that. So friendly note that rules must allow forward traffic to/from you configured host bridge device.
Last updated: 2025-09-22

Post by tvm on VisuFbFrameBase.SetInputPositionData: The element id for the input position cannot be determined CODESYS Forge talk (Post)
I'm getting this error on one of my projects. Searching for it I came across this https://www.codesys.com/fileadmin/data/Images/System/Releaseinformation/Patch-Note-CODESYS-Visualization-4300.html which says it was a bug VIS-1394, fixed in Visualization 4.3.0.0. I'm using a previous visu version, what is the cause of this error, and what can be done to work around it?
Last updated: 2024-02-08

Post by richard-wang on Codesys recipe manager - what does it do? CODESYS Forge talk (Post)
Hi All Thanks for sharing this information. For whom may not know why always get error code 16#4000 or 16#4002 while performing Recipe commands, the root cause is There is a line need to be inserted in CODESYSControl.cfg file, which is PlaceholderFilePath.1=/var/opt/codesys/PlcLogic/ I am using Pi, therefore the above path is set to my pi unit, after adding above line to my cfg file, all the Recipe commands work fine. But I still do not know how and when this file got modified though.
Last updated: 2024-04-29

Post by kurtk on SysProcess Execute Command unable to run commands with special characters CODESYS Forge talk (Post)
Thank you for this additional information. Could you please provide the references to the official documentation where you found this information ? I got as far as: Then insert this: [SysProcess] BasePriority=Realtime Command=AllowAll devoid of references of where the CodesysContol.cfg file was located or of the need to run codesys as root I incrementally located bits of information with perplexity searches but remained mired at error 25 ERR_NO_ACCESS I am curious whether root access is MANDATORY to run SysProcessExecuteCommand (- and/or any other SysProcess functions) or if a more access-constrained User=quasiroot could suffice without the security concerns ? Apparently codesys runs fine without User=root for almost everything... That raises the question: What IS the default codesys user ? I notice in the prototypes: VAR sCommand : STRING := '/usr/bin/whoami'; sOutput : STRING(255); refCommand : REFERENCE TO STRING; refOutput : REFERENCE TO STRING; resultCmd : UDINT; END_VAR whenever I attempt to build this Codesys v3.5 SP2 whines that "cannot convert type REFERENCE TO STRING to STRING" don't remember the exact message... Apparently this happens whenever a fixed-length string is involved. if I get rid of (255) and just set the string := ' '; that is sufficient to make the compiler happy. Is this a recently enforced constraint ? Why does this compile for you and not for me ? There are references to functions / utilities which are used/needed to massage the string references - but I see no specific details... I also notice you specify: Make sure the lib SysProcessImplementation, SysTypes, and CmpErrors is on the project. I don't comprehend why all of the dependent libraries are not automatically referenced, added ? I don't recall seeing anywhere but here that SysProcessImplementation must be included... It just seems odd that the default is to exclude essential libraries, or require alchemical conjuring to assemble all the ingredients for gnat soup ;-) Thanks a lot... I'm still a codesys newby getting my wheels on - or sometimes just partially on
Last updated: 2025-09-12

Get the numer of day CODESYS Forge talk (Thread)
Get the numer of day
Last updated: 2023-09-14

Error index was outside the bounds CODESYS Forge talk (Thread)
Error index was outside the bounds
Last updated: 2023-09-19

Having trouble using the CRC function CODESYS Forge talk (Thread)
Having trouble using the CRC function
Last updated: 2023-02-14

Use of the CPLCHandlerCallback CODESYS Forge talk (Thread)
Use of the CPLCHandlerCallback
Last updated: 2012-02-06

The Codesys 3.5 profile concept CODESYS Forge talk (Thread)
The Codesys 3.5 profile concept
Last updated: 2018-10-23

Problems with the Program CODESYS Forge talk (Thread)
Problems with the Program
Last updated: 2010-02-17

Maintenance of the forum CODESYS Forge talk (Thread)
Maintenance of the forum
Last updated: 2010-07-09

description about the build compiler definition CODESYS Forge talk (Thread)
description about the build compiler definition
Last updated: 2023-09-26

Change the default ssh port CODESYS Forge talk (Thread)
Change the default ssh port
Last updated: 2023-10-11

Post by shabroz-gill on Unable to load boot application on ARMv7 device restart CODESYS Forge talk (Post)
I download an application to an ARMv7 32 bit device. I start the applicatin and it all works fine. But when i restart the device the boot app is not able to start. I have to redownload the application from the development environment to get to run again. I get the following error messages in the log on the restart
Last updated: 2023-11-30

Export data with the Trend API CODESYS Forge talk (Thread)
Export data with the Trend API
Last updated: 2024-07-08

What is the insights of IoDrvEtherCAT.DCInSyncWindow? CODESYS Forge talk (Thread)
What is the insights of IoDrvEtherCAT.DCInSyncWindow?
Last updated: 2024-07-09