Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
Hello, Today I am able to test ma industrial computer in my test bench. I am able to do all the configuration throught my VPN, 100% remote. I can see the gateway & the Virtual PLC. Now I would like to do some Modbus TCP Client & Modbus RS485. But I am lost due to docker ! When I go to modbus TCP it only gave me the docker network, but not my eth0 & eth01 When I go to modbus rtu, how can I create the link between Com number & my /dev/ttyRS485 Loic,
Last updated: 2024-10-23

Post by sercan on Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project CODESYS Forge talk (Post)
I want to run the following command by linking it to the A-Axis: G01 A45.0 Which TRAFO should I use to do this? SMC_TRAFO_5Axes and SMC_TRAFO_GantryCutter3 function blocks did not work! For example, when SMC_TRAFO_5Axes is used, parameters B and C can be resolved by the transformer. However, parameter A cannot be resolved. Only SMC_Interpolator displays the value of parameter A in the SMC_Interpolator => piSetPosition.dA output. Should I drive this axis with SoftMotion commands (MC_MoveAbsolute etc.)?
Last updated: 2025-05-07

Post by ivan-g on MODBUS CODESYS Forge talk (Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a Facebook post that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05

Post by ivan-g on MODBUS CODESYS Forge talk (Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a FB that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05

Post by yann2021 on Execute a .py file with Codesys CODESYS Forge talk (Post)
Hello, I have a Raspberry Pi 3 which has a printer connected to his USB port. I have a PiFace Board on the Raspberry. I have a python script file (.py) to print a logo + a text. The script is working because when I execute it from the Raspberry terminal it works. Now, when I push a button on the PiFace I would like to execute the python script file to print. How can I do that ? Many thanks for your help and advices!
Last updated: 2025-08-26

Post by monw on Unable to Re-Import Native XML Exported Using CODESYS Script API CODESYS Forge talk (Post)
When exporting a Logical Device or Logical Exchange GVL using the native XML export functionality of the CODESYS Script API, I encounter the following error upon re-import: "Error in IEnumeratorOfTWrapper. Current. Could not cast: System.String in System.Char" I am using CODESYS V3.5 SP21 Patch 2. Is there a known solution or workaround for this issue? Notably, importing the same XML file through the CODESYS Engineering IDE's menu import works without error.
Last updated: 2025-09-12

Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
The problem has been resolved. Two findings are described below for future reference. The new RPi hw delivered during August 2025 has a MAC address from a new vendor series that is not supported by old runtimes. 4.17.0.0 or above is required. 4.17.0.0 does not pick up the correct architecture during installation and aarch64 has to be manually configured either in the GUI under operations or in /etc/codesyscontrol/CODESYSControl_User.cfg under the [CmpRasPi] section.
Last updated: 2025-09-16

Post by nano on Is there any support for I2C on Raspberry Pi? CODESYS Forge talk (Post)
hello jdj this question can be answered well with a pretty good forge documentation: https://forge.codesys.com/drv/io-drivers/doc/Generic/ u r also able to create in codesys directly an iec-code by using the i2c-interface as driver using the codesys ide and st depending on the stepperdriver, used in yΓΆur hat, its possible that an driver is already available in the device-repository. which mcp-device is used on the hat?
Last updated: 2024-03-01

Post by niallel on How to change bHiresMode CODESYS Forge talk (Post)
Hi, I'm trying to get Scaling working on my axis. An increment produces 36.6mm of movement, so I want to put the units in application as 36.6. However the docs say that I need to change bHiresMode as it doesn't show me the option for Precision in the User Interface. I'm thinking that I need to change the precision so I can enter decimal places. How can I do this, or is my thinking wrong? Thanks,
Last updated: 2024-03-11

Post by ofey on EtherCAT fieldbus CODESYS Forge talk (Post)
Okey, thank you! Do you think it is something in this library, that makes it possible to do the configuration in a PRG? https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/IoDrvEtherCAT.html#id1 I think the codesys modbus libraries support configuration and connection to modbus slaves without having to add the slave devices in the device tree. Just do it from function blocks inside the program. I was hoping for something similar with EtherCAT.
Last updated: 2024-04-10

Post by ph0010421 on General question about library versions CODESYS Forge talk (Post)
Hello I can't find anything to read on the subject so I'll ask here. Up to now, when adding a (for example) Modbus Master, I've selected the version <= the RT version, so if I'm using SP13 Patch 3, I can use a library that doesn't exceed this. I've no idea if this is correct, but it's always worked. Can someone explain the 4.x.x.x libraries that have appeared; are they tied to a RT version? The controller I use is now at SP18Patch60, so should I continue to use 3.5.xxx or change? thanks
Last updated: 2024-05-29

Post by joep on Custom robotics kinematics model debugging CODESYS Forge talk (Post)
When trying to move my axis using any group move instruction I get the following error: SMC_CP_INVALID_PATH_ELEM and axisgroup goes into errorstop state. I tested my methods thoroughly which makes it hard for me to debug. Are there some hidden rules I need to abide to? How would one go about debugging a custom robotics model, since the information inside isn't accesible. Is it possible to find the source of where the function breaks? Any hint in the right direction would be appreciated. Best regards
Last updated: 2024-06-08

Post by nxbp on About Compatibility CODESYS Forge talk (Post)
Let's say I have a CODESYS controller (PLC) with a runtime version around 3.5.19. If I use development software version 3.5.21.40 or a later version that will be released in the future for programming, could there be any problems or malfunctions in the controller's program execution or in the execution of the new, updated function blocks from the newer software? I mostly work with servo-based motion applications, so please keep that in mind when answering, and provide a detailed answer so I don't have to email you again about this topic.
Last updated: 2025-12-11

Post by mohi on Connect to Azure IoT Hub CODESYS Forge talk (Post)
Hello, I try to connect a Controller to Azure IoT Hub using a Root Certificate put on the controller in /etc/ssl/certs und SAS Token for IoT Hub instead of X.509 certificates. The TLS Handshake is successful when I test in terminal using openssl. It seems that the Controller doesn't start this process. I use the Azure IoT Hub library and the Net Base Services. Is there something left or something you can recommend? Best regards Mo
Last updated: 2026-04-24

Post by mohi on Connect to Azure IoT Hub CODESYS Forge talk (Post)
Hello, I try to connect a Controller to Azure IoT Hub using a Root Certificate put on the controller in /etc/ssl/certs und SAS Token for IoT Hub instead of X.509 certificates. The TLS Handshake is successful when I test in terminal using openssl. It seems that the Controller doesn't start this process. I use the Azure IoT Hub library and the Net Base Services. Is there something left or something you can recommend? Best regards Mo
Last updated: 2026-04-24

Post by timvh on HTML5 visualization controls disabled on CODESYS Control for Linux SL - overlay not supported? CODESYS Forge talk (Post)
I would suggest to install the latest visualization and visualization add-ons. Go to Tools - CODESYS installer to updates these add-ons (or just start the CODESYS installer through the Windows start menu). After installation, restart CODESYS SP22 and update the project to use this new visualization profile (you can update this through the menu Project - Project Environment - Visualization Profile).
Last updated: 2026-08-05

How to call the same program from library and get the vars updated. CODESYS Forge talk (Thread)
How to call the same program from library and get the vars updated.
Last updated: 2023-08-23

Post by mubeta on parker servo and position CODESYS Forge talk (Post)
Reading between the lines of what you did not specify, it therefore seems to appear that in the programme, at the end of the movement order, there is an order to remove power and switch off the pulse modulation. if this is the case, it is obvious that the motor then remains free. If the position is to be maintained at the end of the movement, the motor current modulator, which on the PLC side is controlled via the MC_Power method, must not be interrupted. Another possibility is that in the motor drive settings, the standstill torque current is set very low or zero and without position monitoring. You have to check this via the servo motor drive.
Last updated: 2024-08-05

The Ultimate Guide to Taxi Services in the UK: From Airports to City Travels CODESYS Forge talk (Thread)
The Ultimate Guide to Taxi Services in the UK: From Airports to City Travels
Last updated: 2024-08-08

Post by faceplant on Get the .git folder path via scripting CODESYS Forge talk (Post)
Using the git scripting API, is there any way to get the file path of the project's .git/ folder?
Last updated: 2024-08-08

Modbus: Is there a way to get the channel index from the channel name? CODESYS Forge talk (Thread)
Modbus: Is there a way to get the channel index from the channel name?
Last updated: 2024-10-21

Programmatically change the IP addresses of the Modbus TCP slave devices CODESYS Forge talk (Thread)
Programmatically change the IP addresses of the Modbus TCP slave devices
Last updated: 2024-12-11

Post by bertcom on STRING conversions to DWORD CODESYS Forge talk (Post)
@trusty-suire, The problem is not encoding. The problem is that codesys ands ' ' to the string. And the printer can't handle these character.
Last updated: 2025-01-30

Post by bertcom on STRING conversions to DWORD CODESYS Forge talk (Post)
@trusty-suire, The problem is not encoding. The problem is that codesys ands ' ' to the string. And the printer can't handle these character.
Last updated: 2025-01-30

Post by eschwellinger on Creating, using an external Function. CODESYS Forge talk (Post)
you need the check the plclog if the the component have been loaded on startup of th plc.
Last updated: 2025-04-19