Post by vtec35 on search runtime 4.9.0.0 for pi 3
CODESYS Forge
talk
(Post)
Hello everyone, following corrupted data on the SD card of our Pi3B+ provided with a machine, we reinstalled a CODESYS image for Raspberry Pi, but we cannot find the 4.9.0.0 runtime that is compatible with the project. Currently, the machine is on 4.1.0.0, and we tried a more recent version 4.13.0.0, but there are error messages. Thanks in advance.
Last updated: 2025-10-24
Post by aseitzinger on CODESYS Control for Linux SL on virtual machine?
CODESYS Forge
talk
(Post)
Hello, there in different information available regarding the possibility to run CODESYS Control for Linux SL on a virtual machine. https://forge.codesys.com/trg/linux-sl/home/Home/ says CODESYS Control for Linux SL is a runtime system, which can run on any Debian based X86 PC, VM or Cloud container... https://store.codesys.com/media/n98_media_assets/files/2302000005/3/CODESYS%20Control%20for%20Linux%20SL_de.pdf says CODESYS Control for Linux SL can not be used on virtual hardware Currently I run the package mentioned on a virtualized debian machine running in PROXMOX Virtual Environment 7.4-17 and apart from huge jitter it runs without problems. The CODESYS key is passed as a USB defice to the VM. I wonder why there are different statements regarding the suitability in virtual machines and if the jitter would be reduced by installing CODESYS runtime on the host installing CDS runtime on the host and using a preemptive kernel (if available for the PROXMOX installation leaving CDS runtime where it is (on the virtualized debian machine) and install a preemptive kernel on the host and on the guest... Any advice is appreciated. Greets Arno
Last updated: 2024-01-08
Post by martinlithlith on Relay board / relays for raspberry pi 3 b+
CODESYS Forge
talk
(Post)
hi! im planning a project on a raspberry with Codesys. For this I'll need a number of relays to control heating and fans, all a max of 24v and about 2a. How would i know if the board / relays i buy will be working with Codesys? Does every hat work or does it need a library/driver? is there a list of drivers/libraries created? as this is a hobby project all tips on a relay board or single boards that works with codesys and not to expensive are very welcome.
Last updated: 2023-09-03
Post by trusty-squire on How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Post)
For general usage, these links might help you out. If you are looking at using I2C interfaces, examples from the Raspberry Pi will probably be useful, even if your board isn't a Raspberry Pi. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_rts_serial_com.html https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_raspberry.html If you're developing your own drivers, I can't help you there, although the link you provided will help. If you drill in deeper, the I2C page for example shows function block and method usage, etc. Good luck!
Last updated: 2024-08-09
Post by johnbomb on Ignore Dependencies When Loading Package?
CODESYS Forge
talk
(Post)
I'm trying to load a .package into Codesys 3.5.21, but the package is intended to only work with Codesys 3.5.18.0 and is configured with dependencies on the specific versions of other packages included with 3.5.18.0, and 21 has newer versions so the package will not install. I would like to install the package anyway to try and get things working on a newer Codesys version, since for some reason the installer for .18 errors out and doesn't fully work in my environment, but .21 seems to work fine.
Last updated: 2025-04-01
Post by eboyd on AOI's
CODESYS Forge
talk
(Post)
Hello, I'm currently working on transferring a project I recently created on Studio 5000 to CODESYS and unfortunately CODESYS isn't compatible with AOI's so I was wondering if there was anyone who could help me transfer these L5X AOI blocks to ST Function Blocks that I can import into CODESYS so I can use them for this project or if you know where I can find preexisting Function Blocks for these AOI's. Thank you so much!
Last updated: 2025-09-02
Post by eboyd on AOI's
CODESYS Forge
talk
(Post)
Hello, I'm currently working on transferring a project I recently created on Studio 5000 to CODESYS and unfortunately CODESYS isn't compatible with AOI's so I was wondering if there was anyone who could help me transfer these L5X AOI blocks to ST Function Blocks that I can import into CODESYS so I can use them for this project or if you know where I can find preexisting Function Blocks for these AOI's. Thank you so much!
Last updated: 2025-09-02
Post by clarenced on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks
CODESYS Forge
talk
(Post)
Using codesys v3.5 SP21 Patch 1. We are using Visualization to display alarms. Other then the automatically created AlarmManagerTask, there is no code written to call AlarmStorage_Prg. Any ideas why we would be seeing this error in the log? The runtime actually shutdown. Not sure if that was caused by this error or not. 2025-08-03T02:45:35.444Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T03:48:15.294Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T04:38:11.557Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * 2025-08-03T04:38:11.576Z, 0x0000010f, 8, 1, 0, #### Exception: SysSemEnter - Semaphore deadlock detected - owner thread died [tid:726740] - system may be in an inconsistent state. 2025-08-03T04:38:11.576Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-08-03T04:38:11.576Z, 0x00000001, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-08-03T04:40:12.308Z, 0x00000001, 1, 0, 35, CODESYS Control shutdown... 2025-08-03T04:40:13.436Z, 0x00000071, 1, 0, 13, Webserver stopped 2025-08-03T04:40:13.437Z, 0x00000114, 2, 1, 0, !!!! Warning: task_signalhandler_exit [MainTask] lost cycles: 14809 2025-08-03T04:40:13.497Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IecVarAccess</cmp>, <id>0x00001007</id> <ver>3.5.3.64</ver> 2025-08-03T04:40:13.506Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>AlarmMgr</cmp>, <id>0x00001012</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.513Z, 0x00000071, 2, 0, 14, !!!! Warning: Unbalanced calls to WebServerRequestRunning/WebServerReleaseRunning 2025-08-03T04:40:13.513Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IECVisualization</cmp>, <id>0x0000100c</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:50:17.708Z, 0x00000001, 1, 0, 36, CODESYS Control shutdown done
Last updated: 2025-08-04
Post by chris--o on ModbusTCP RaspberryPi zu Fronius Wechselrichter
CODESYS Forge
talk
(Post)
Hallo zusammen, ich hab ein kleines Problem bei einer Modbus TCP-Verbindung von meinem RaspberryPi (ML) zu einem Fronius Wechselrichter. Ich habe mir die CodeSys Version 3.5SP20 heruntergeladen und die Runtime auf dem RaspberryPi mit aktualisiert. Gerät ist ein Fronius Symo 6.0-3-M Folgende Konfiguration habe ich im Wechselrichter (Siehe Bilder). Laut Registertabelle fangen die Daten bei Adresse 40001 an und gehen im Modus int+SF bis 40120 Ich habe mir also im Ethernet-Adapter einen Modubus Master und darunter einen ModbusSlave angelegt. Der Slave (Fronius) hat bei mir die IP 192.168.2.46 dazu UnitID und Port. Ich habe dann einen Kanal mit den 120 WORDS und dem OFFSET angelegt. Wenn ich nun die Konfiguration übertrage , scheint erst mal alles zu passen.. aber es flackert immer wieder ein Fehler beim Slave auf (kann nicht erkennen welcher und finde auch keine Diagnose). Es werden auch keine Daten übertragen. Alles bleibt auf 0. Ich muss dazu sagen, dass ich noch eine weiter Modbus TCP Verbindung zu einer anderen SPS habe. Die funktioniert wunderbar. Normalerweise sollten ja auch mehrere Verbindungen gleichzeitig möglich sein oder? Wäre top, wenn ihr mir helfen könntet, den Fehler zu finden. LG Chris
Last updated: 2025-06-30
Post by ragarcia on Error while using UpdateConfiguredIPSettings to change IP address
CODESYS Forge
talk
(Post)
Hello everyone, I am trying to change dynamically by code the IP address of a Weidmuller controller. So I am basically using IoDrvEthernet library to use UpdateConfiguredIPSettings function but I am getting constantly the 'INVALID_STATE' error. Even though I am following a procedure it should work: * First I added on the config file of codesys the following: [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="eth1" Adapter.1.EnableSetIpAndMask=1 * Secondly I am first disabling the ethernet interface by using Ethernet_0.Enable = FALSE and then executing DED.Reconfigure. After that, I run the Ethernet_1.updateConfiguredIPSettings Code: Ethernet_1.Enable:= EnableDisable; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1, xError=> ErrorReconfigure, eError=> ErrorCodeReconfigure); IF Reconfigure.xDone THEN ErrorCodeIP:= Ethernet_1.UpdateConfiguredIPSettings(IPAddress:= newIP, SubnetMask:= newMask, Gateway:= newGW); END_IF IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Ethernet_1.Enable:= TRUE; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1); IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Can someone help me? Thank you. All I am trying is to find a way to change dynamically with code, the IP addresses of my controller (2 ethernet ports).
Last updated: 2023-12-11
Post by vsgn on Passing properties as VAR_IN_OUT variables.
CODESYS Forge
talk
(Post)
Hi, in my experience, the best options for such a case could be: 1. Pass a FunctionBlock via VAR_IN_OUT, containing all variables, mehods and properties needed for the logic of this graphic element (be aware of implementing correcly both get and set accessor for properties) 2. Pass an Interface via VAR_INPUT, of which you can use obviously only Properties and Methods. This is much more elegant for me. Here, you can just pass directly the instance of a FunctionBlock implementing such Interface as input. Hope you'll find this suggestions useful.
Last updated: 2025-05-13
Post by simover on TCP/IP client
CODESYS Forge
talk
(Post)
I want to send a string to a tics TCP/IP server. I got i working with the Net Base lib. for communication good with this tcis i need to by array of byte I want to include a string in the third position of the array TCIS_Send[1] :=254; //this valus is fix for evry communication TCIS_Send[2] :=80; //this valus is fix for evry communication TCIS_Send[3] := ; here I put my and my string is lik this 5806509-DRAP10#AB#3452302073 TCIS_Send[4] :=252; //this valus is fix for evry communication
Last updated: 2023-12-18
Post by aniket-b on Multiple function blocks are not executing at the same time in ladder logic
CODESYS Forge
talk
(Post)
I have two ethernet Ip drives and created Function Blocks for different motions tasks. I am using same FB for both the drives. When I try to execute the relative move start command on FB for both the drives it is not working. However, if I add 1ms second delay between the execution of each drive it is working. Also when I change the rung order it is working for the first drive in the rung. what could be the wrong here?
Last updated: 2024-03-12
Post by kalmeyer on NO SIGNAL ON POWER_ON FOR STEPPER MOTOR
CODESYS Forge
talk
(Post)
I WOULD BE GRATEFUL FOR HELP....✔✔✔ I HAVE SPENT A LOT OF TIME ON THIS "SMALL" PROBLEM😢 I HAVE MADE A MC_POWER FOR STEPPERMOTOR. BUT I DO NOT GET A "HIGH" ON THE STATUS OUTPUT EVEN THOUGH PENABLE, PREG AND PDRIVESTART ARE ACTIVATED ( SEE ATTACHED WRONG_1) HAD I MADE SOME ERROR IN PLC_PRG_1..???? (WRONG_2) 1000 THANKS FOR HELP WITH THIS PROBLEM. 👀👀 /KLAUS FROM DENMARK
Last updated: 2025-11-23
Post by ivanmaltar on Update Raspberry Pi error
CODESYS Forge
talk
(Post)
Hello, from today, I got an error when I try to open 'Tools/Update Raspberry Pi' and I got this error: There is no value with the specified name associated with this subkey. This feature worked before. I did not do any changes to Codesys installation. Codesys version is SP19.1, and CODESYS Control For Raspberry Pi 4.8.0.0
Last updated: 2023-11-30
Post by eschwellinger on Gateway
CODESYS Forge
talk
(Post)
yes, sorry this is an accident in current Gateway Version. Either use 3.5.20.0 Version. (download from CODESYS Store standalone setup - https://store.codesys.com/en/codesys-edge-gateway-for-windows.html ) or do it manually by: 1. stop Gateway: 2. Add in c:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSGatewayV3\xxxxxxxx\Gateway.cfg [CmpEdgeGateway] MaintenanceMode=1 3. start Gateway again 4. add it to your CAS Instance
Last updated: 2024-09-18
Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64
CODESYS Forge
talk
(Post)
I am using Codesys Control RTE V3 Version 3.5.21.0 I am not sure what you are asking. Which hardware ID has the network interface card? I have ran ipconfig /all and attached an image. Let me know what other information I can provide to you to help troubleshoot this problem. Thank
Last updated: 2025-03-18
Post by respl on Anyone Ever use CAN with Kollmorgen S600 Drive
CODESYS Forge
talk
(Post)
Dear eschwellinger, Can you please share which library to use. Also if possible please share backup it really help us. On Codesys Store there are many ( CoDeSys Softmotion) option available. Please guide me to choose right product which has driver for servostar 600 as mention above. Regards, Rahul Sayre service.retrofilm@gmail.com +91-9607140005
Last updated: 2025-04-15
Post by fionexyan on Codesys Installation Always Freeze when the installing is almost done
CODESYS Forge
talk
(Post)
Hello Everyone , I have try in repeatedly with uninstall and reinstall the Codesys software and even turn-off the antivirus application before implement to reinstall the codesys ,but at the consequence the problem still same although go with such method, therefore is there any solution for this issue . Thank You .
Last updated: 2025-05-16
Post by pmasip on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
So none of the images from the 64bit archive work with any Codesys Control versions? I have tried the last Pi OS with every Codesys Control version and they don't work. I was wondering if there's any stable combination of versions.
Last updated: 2024-01-04
Post by davidbo on i2c How does CODESYS handle exception or error messages.
CODESYS Forge
talk
(Post)
For Raspberry Pi I have made a python script which regularly read a bulk of data over the ic2 from a device. Sometimes I get an Exception an IOError. I assume similar things can happen in CODESYS. So how does CODESYS handle that? Can I get any info about such an event?
Last updated: 2024-02-07
Post by camilloo on Control for Linux SL on Ubuntu Core
CODESYS Forge
talk
(Post)
Hello, Has anyone tried running CODESYS Linux on Ubuntu Core? I'm having problems installing the runtime. The connection to UC cannot be established. I used the instruction: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_linux_public_key_authentification.html I can connect to UC using SSH (putty, shell). Codesys can't. Do any of you have an idea?
Last updated: 2024-02-24
Post by yigitcant on Configuring a CIP object for Explicit Message
CODESYS Forge
talk
(Post)
Hello sir, ı am new player in codesys env. I wonder that how to communicate with Fanuc robot and Codesys, ı wanna use explicit message EIP but ı don't find an usefull manual in codesys env. Pls share me your project I can not find CIP protocol
Last updated: 2025-10-22
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
For those who will step on this thread. Everything is fine, I had only to increase by 1 my place holders number. For sure the system is occupying the number 1 without being declared ... Below the modification I made to get my code working. [SysFile] PlaceholderFilePath.2=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.3=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.4=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.5=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by sukrit on What licenses are required for runtime on raspberry pi cm4
CODESYS Forge
talk
(Post)
We have developed a project for 2 servo motors using raspberry pi computemodule 4 on ethercat master. we are using web visualization for display different screens. project is running well in demo. we want to implement it in production envoirment. being new still wondering which licences i need. Can We get this information in codesys devlopment software. code size is approx 5 mb, 1 instance of etharcat master and aproox 100 variables in visaualization.
Last updated: 2023-10-17
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.