Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16
Post by mp9876 on Device logon problem following fresh install
CODESYS Forge
talk
(Post)
All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. ‘Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh install: YES then: Initially went with Administrator twice (user & password) but it did not like it. No device is responding to …: Continued by setting a new user Pressed OK and obtained the following message: Stopped and Restarted PLC at that point: Obtained the following: Attempted to login a 2nd time without success. Then I scanned the network to see if matching device can be detected: Only way to get it detected was to remove the tick in the ‘Hide non-matching devices…’ Attempted a WINK but got a return like this one: REFRESH either @ Users and Groups or @ Access Rights returns: Then created user ‘mp’ at Project level ang logged in: Understandably device user mp9876 was not valid for the Project. Device information A few questions comes to my mind following these connection attempts: 1- Gateway not configured properly message pops out because of a non-compatible device ? 2- Why would the device not be compatible ? 3- Any way to make the device compatible ? 4- Any ideas on how to get this connectivity problem to the device solved ?
Last updated: 2024-03-17
Post by alexgooi on Codesys KNX implementation
CODESYS Forge
talk
(Post)
Dear forum, We are currently doing some research on the Codesys KNX implementation (https://store.codesys.com/en/codesys-knx-sl.html). We almost have it working but we are missing the last part. The setup: We have a Codesys virtual control container running on docker (4.17.0.0), the I/O is running over an Ethernet IP coupler (Weidmüller), and this is running fine. As far as I’m concerned this tells me that the ethernet device is working properly (the container has access to the outside world, including multicast). Underneath this ethernet adapter the KNX module is added (see picture). In the KNX device (Codesys) 2 input variables are added (see picture), and these are exported to ETS (ETS 5). In ETS A Codesys KNX device has been imported and the Codesys export was imported, afterwards the group addresses are attached to the variables (see picture). Afterwards this configuration is downloaded to the Codesys controller (Container) via ETS. ETS asks for the pressing of the programming button, when the virtual programming button is pressed the download starts and finishes without any errors. This tells me that ETS is communicating with the Codesys controller, and that the download process is ok (so far so good). Now the part where we are struggling with, somehow we need to convert the KNX TP to KNX IP. For this we have the following interface: Zenio KIPI SC (https://www.zennio.com/product/kipi-sc/) this is a KNX TP to IP interface. We have the following setup for this device (see picture) (an IP in the same subnet is used). We tried multiple combinations of IP addresses but the TP devices are simply not communicating to the Codesys container. Does anyone has any advice on what to try next. To make the question more explicit how can we link the TP bus to the Codesys device? Kind Regards Alex
Last updated: 2026-01-05
Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation
CODESYS Forge
talk
(Post)
Good morning, I’ve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object I’m running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I don’t understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesn’t report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case I’m working on an isolated single core. I’ve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. I’d like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11
Post by paulg on RasPi CAA Serial example - unexpected behavior during debug
CODESYS Forge
talk
(Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06
Post by thn-power on Updating OPC UA Core Nodeset on PLS
CODESYS Forge
talk
(Post)
Hi After much trail and error I think I found the root cause to my OPC UA problem. The problem is that I cannot manage to build and download a program with a a custom OPC UA Information model. We use a Weidmueller WL2000 PLS, but the problem also exsist on the Win V3 PLC. Our custom information model is based on the latest versions of the OPC UA Core Nodeset v 1.05.03 (2023-09-20) and UA/DI nodeset 1.04.0 (2022-11-03) Those nodesets are installed in the Codesys Information Model Repository (3.5.19.6) However, when trying to build I get the following error. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://bos.org/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/DI/ is required by http://bos.org/ with a minimal publication date from 03.11.2022 but the device has only a model from 09.03.2021 installed. Probably the information model from 09.03.2021 is missing in the information model repository. Build complete -- 2 errors, 1 warnings : No download possible I think the problem is that the UA Core nodeset is implemented in the PLC firmware (at least that in Siemens S7), and that only includes the "old" nodeset from 2021-09-21 etc. So the question is, how (or if?) can I transfer the new nodeset to the PLS? I have created separate Information models under Communication manager with the newer code nodesets (UA and DI). But it seems that the compiler does not recognize them being excising, neither in the Codesys IDE or on the PLC. Would have guessed that this is a common issue, sine many manufacturers use the latest versions of the OPC UA standard, and that it would be a solution to the problem.
Last updated: 2024-09-20
Post by gilbert-mh on CAA net base TCP client cause PLC to crash - Kernel message : N0HZ_local_softirq_pending 80
CODESYS Forge
talk
(Post)
Hello all, I have been trying to implement a TCP client on a Festo PLC (CPX-E-CEC-M1) and it looks like it works well except that after some time (greatly varies between a few hours to more than 100h) my PLC crash. When I look into the log file the only thing I see is that before the crash happens a few kernel warnings : N0HZ_local_softirq_pending 80 and then the crash. I've looked into this warning and from what I could find on the net it seems that this is warning is triggered when the ethernet link is down. I've tried to correct this bug for quite some time and what I know is that : - The crash is caused by my TCP client, when I remove it from my code I see no crash - The crash happens more quickly the more the TCP client is used. - The time before the crash is not directly proportional to the number of communications or their size. But it looks like it is just more likely to happen if the client connect to the server at a higher frequency. - The precedent observation makes it seem unlikely that the crash is caused by some memory overflow because then the crash speed would be more proportional to the amount of data exchanged. SO from these observations, I believe that the crash could be caused by the PLC trying to connect to a server while there is some kind of issue with the ethernet link resulting in the PLC getting stuck in some indefinite state and making it crash. This still seems a bit unlikely to me because if the ethernet is down it simply shouldn't be able to contact the server and the communication would just fail which doesn't cause my PLC to crash. Has anyone encountered the same kind of problem (with the same kernel message) ? I am pretty sure the warning is not the direct cause of the crash but just an indicator that something is wrong with my PLC. Thanks in advance
Last updated: 2024-01-12
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14
Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys
CODESYS Forge
talk
(Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol in codesys, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25
Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys
CODESYS Forge
talk
(Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello I am using an OpusA3 with version 3.5 SP17 Patch 3 as part of a project. I had no real problem before I encountered a problem that blocked me. The detection of the OpusA3 from Codesys is done correctly. The gateway is well configured and if I ping the gateway or the OpusA3 I receive the response correctly. The problem is that when I try to connect, the Opus screen freezes and a few moments later Codesys displays an error message ("connection to device closed"). I tried to change PC, to update the runtime, to change OpusA3 but the problem remains the same. I'm a little lost knowing that before it worked without problem. I went back to a previous version of the project (where it worked correctly) but the message still appears. Do you have any clues to solve the problem? Sincerely,
Last updated: 2023-08-23
Post by janderson on OPC UA Server limitations, large array crashes runtime
CODESYS Forge
talk
(Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23
Post by muhq on Profinet connection to Siemens CP343-1 Lean (IO-Device/Slave)
CODESYS Forge
talk
(Post)
Hi, I am quite new to Codesys and I try to do a Profinet connection to an Siemens PLC (315-2DP) with CP343-1 Lean Modul. I already configured the Siemens PLC, exported the GSDML. Then I added a new project in Codesys, added following moduls: - Ethernet - PN_Controller - Imported Profinet Device via GSDML importer When I start the programm everything looks fine but I always get the message "Stopped Profinet" and no data is available This is only for a small test. Therefore I start to do that on a Windows 10 with Development System. Later I will try to realize this on Raspberry. Ethernet Adapter is configured (192.168.1.1 / 24) Firewall deactivated WinPCap is installed S7-Station seems to be found ('fuadazenzitest') Can please somebody help me?
Last updated: 2023-08-26
Post by tvm on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS)
CODESYS Forge
talk
(Post)
ok, that's different than our issue then. We're using Schneider Electric M262 PLCs, and we've had it where certain web browsers cause the web server to only allow https connections, but it's not recoverable with a refresh. It usually requires a power cycle or even a full firmware flash. Your issue might have more to do with the timing. I don't know if it helps you, but we normally run our visu task at 200mS, with an update rate of 200mS. Seems to work. I went through this: https://faq.codesys.com/pages/viewpage.action?pageId=112525371 but it really seems like trial and error.
Last updated: 2023-09-06
Post by lraja on Codesys Programming with phyBOARD®-Pollux i.MX8M Plus
CODESYS Forge
talk
(Post)
Dear All, I am trying to Developing a PLC using phyBOARD®-Pollux i.MX 8M Plus. It is very difficult to find the suitable Codesys control for i.MX8M. I have tried to install CODESYS Control for Linux ARM SL , but unable install it and I am getting the following error, [INFORMATION] Executing SSH command on root@192.168.0.10: Retrieving architecture from package management [ERROR] Expected exit value of command failed: expected 0, received 127 [INFORMATION] Standard output: sh: line 1: dpkg: command not found Kindly check and help phyBOARD®-Pollux i.MX 8M Plus Link : https://www.phytec.eu/en/produkte/single-board-computer/phyboard-pollux/
Last updated: 2023-09-23
Post by smartcoco on The text list provided outside the library is not available for visualization controls within the library.
CODESYS Forge
talk
(Post)
I have a project called 'DemoProject' and a library called 'DemoLib'. Create a visual control named "DemoVisu" in the library, with a selection box of type "ComboBoxInteger" in the space. Now 'ComboBoxInteger' requires a 'Text list'. This "Text list" is provided when I call the "DemoVisu" control of the "DemoLib" library in "DemoProject". And this text list is in 'DemoProject'. I found that 'ComboBoxInteger' no longer works at this time. Other visual controls that use text lists also have this issue. I hope there is a good solution to this problem.
Last updated: 2023-10-16
Post by benediktenger on Access project information of references library by script
CODESYS Forge
talk
(Post)
Hi, I need to accesss to project information of a referenced library in the project. At least I need the "Released" flag from these information to check that no project gets shipped with unreleased libraries. Unfortunally, I do not get this information by script. I archieved to get the library reference object and the managed library object but both won't give me this flag but only basic information like company, name, version, etc. Here is my code: # get the library refernces proj = projects.primary objects = proj.get_children(recursive=True) for object in objects: if object.is_libman: for libref in iter(object): if libref.is_placeholder and isinstance(libref.effective_resolution,str): print(libref) print(libref.name) # get the managed libraries libs = librarymanager.get_all_libraries() for lib in libs: print(lib.displayname) print(lib.version) Does somebody know how do get these information?
Last updated: 2023-10-23
Post by jerry-sorrells on Find Function: Object reference not set to an instance of an object.
CODESYS Forge
talk
(Post)
Build: CODESYS 3.5 SP19 Patch 1 (64-bit) Host OS: Windows 10 Target: Linux SL I have a project with programs in Structured Text and Ladder Diagram. When I try to use the Find function, it works for the Active Editor; however, when I try to use Find for the Entire Project, I get the error "Object reference not set to the instance of an object." I know what this error means in the context of the program, but I have no idea why the find function is returning this error. The variable I am searching does not matter: it happens with all variables. Any help with this will be greatly appreciated. I generally use the Find function quite often as I am developing and not having it is really slowing me down.
Last updated: 2023-10-23
Post by macros8 on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi, I haven´t noticed you put the comment here. I thing it´s a bit different. What I want is to have detail errors of technology in data type e.g. INT. This variable I would latch to the corresponding error msg but I would like to get it convert to text from the text list and not keep it in INT form. Example. Main error Valve Error: SubErrors 1 - Both sensors 2 - Not retracted in time 3 - Not pulled out in time In HMI Main error + latch SubErrors => "Valve Error: Both sensors" The benefit is that text lists are part of translation and can be easily manipulated. I know I can create whole string msg in PLC but then, it lose advantage of Alarm management. Thanks. M.
Last updated: 2023-11-07
Post by gurke258 on Codesys Safety EtherCAT with Beckhoff
CODESYS Forge
talk
(Post)
Hello :) We are currently configuring a system with Codesys as SoftPLC on a Linux system and with Beckhoff terminals. I have already gained some experience with Codesys and also with TwinCat incl. TwinCAT Safety. What is new to me now is Codesys in conjunction with Beckhoff safety terminals. We are currently using an EL1918 & EL2904 here. I have been able to integrate both terminals into my project, but I don't know how to interconnect them so that they communicate. That's a bit easier with Twincat ^^ Can any of you help me? I would also prefer a Codesys EtherCAT Safety training or webinar if anyone knows of one. Unfortunately I can't find such an event on the internet.
Last updated: 2023-11-07
Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
Hallo, I have a strange problem with the recipe manager. ISSUE: When using RecipeManCommands not all values are loaded correctly. Saving a recipe with CreateRecipe(), ReadAndSaveRecipe() or ReadAndSaveRecipeAs() works without any problems. BUT: LoadRecipe(), WriteRecipe() or LoadFromAndWriteRecipe() do not load the data correctly. It is Interesting that we have a different error pattern with LoadRecipe() than with WriteRecipe() or LoadFromAndWriteRecipe(). LoadRecipe() does not load all data and WriteRecipe() or LoadFromAndWriteRecipe() overwrites some data or assigns it incorrectly. And it is also strange that LoadRecipe() writes the values to the PLC. Normally it doesn’t do it. It makes no difference whether the memory type is textual or binary. I have an object consisting of STRUCTs which is inserted in the recipe definition. Environment: Codesys V3.5 SP19 Patch 4 (64Bit), Recipe Management 4.2.0.0 *Add a project (reduced to the problem)
Last updated: 2023-11-15
Post by bahrt on Raspberry Pi GPIO mapping
CODESYS Forge
talk
(Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IO’s become available with the corresponding mapped IO’s – the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are not active (at a fixed zero state) in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-21
Post by tomgr on Codesys 3.5.19 Control Win x64 - network adapter for EtherCAT master not working
CODESYS Forge
talk
(Post)
Hi guys I am trying to run on my laptop Codesys 3.5.19 Control Win x64 where I created a EtherCAT master. I have defined the controler, specified network adapter (my docking station) and everything worked as expected. Later I needed to test it on site (without docking station) so I changed the network adapter by EC master to my laptop network card. After that it shows "Network adapter opened" but no device can be found by scanning and in LOG is saying "SysEthernet: packet could not be sent, error code: -1". Same error with USB network card, but if I switch back to docking station, all is working again... Any idea what I'm doing wrong?
Last updated: 2023-11-22
Post by riccardo on Codesys SP19 patch 4
CODESYS Forge
talk
(Post)
Hallo everyone, I am working on new PLC of Weidmueller that uses Codesys SP19. I made the upgrade at the Patch 4 coming from patch 0. Unce made the upgrade everything is working well in the progect except the web visu user menagent. In the new version, when I perfom the login, I cannot use the keyboard of the device; the window where to digit the user name and password opens, the buttons "OK" and "Cancel" work but the system doesn't allow to put input from the device keybord, the mouse behaves as it is an image. If I active the virtual keypad or numpad it works otherwise nothing. I am wondering if it is a bug of the new package or if I must set something else. Thanks in advance, Riccardo.
Last updated: 2023-11-27
Post by mahmutbeyaz on Create a Motion Profile
CODESYS Forge
talk
(Post)
Dear All, I hope first to get notice and somebody answer my question. How can I create a motion profile with the axis following it (once or periodically)? As my research shows, Schineder has a UI-based (Motion Sizer) program that helps create a motion with different configurations, which is Codesys-based. I need to create a motion profile based on position, changing the speed. (i.e., 0-300mm moves with 300 mm/s, 300-400mm moves with 500 mm/s, 500-800mm moves with 1000 mm/s, and 800-0mm moves with 2000 mm/s). MC_PositionProfile does it time-based, which is not working for me as the axis may not stabilize the position in time, which may cause a big failure in the system.
Last updated: 2023-11-30