Post by e13740e on Parameterized Property syntax for array element processing CODESYS Forge talk (Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT <index_name> : <index_type>; // One or more index parameters are declared here END_VAR</index_type></index_name></data_type></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY
Last updated: 2025-10-09

Post by e13740e on Parameterized Property syntax for array element processing CODESYS Forge talk (Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT // One or more index parameters are declared here <index_name> : <index_type>; END_VAR</index_type></index_name></data_type></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY
Last updated: 2025-10-09

Post by giackanto on Eoe issues with Windows and Linux CODESYS Forge talk (Post)
Hello, I've been trying to use EoE for communication between a Windows PC and an M753 drive from Control Technique. Despite following some online guides (https://content.helpme-codesys.com/en/libs/EtherCATStack/4.3.0.0/Ethernet_over_EtherCAT/fld-Ethernet_over_EtherCAT.html) I haven’t had any success. Both are connected to a Debian device where RTE is running: The PC is connected via the Ethernet port. The drive is connected via the EtherCAT port. I'm unable to ping the drive from my Windows PC. Here is my configuration: On Debian: (See attachments 1, 2, 3) enp1s0 = Ethernet port enp2s0 = EtherCAT port tap2 = TAP device IP forwarding and routes are both configured. On Windows: (See attachments 4, 5) On Codesys: (See attachments 6, 7) Version: Windows 11 Debian GNU/Linux 11 Codesys 3.5.17 Control for Linux SL 4.7.0 EtherCAT 4.4.0 With this configuration, I can ping the TAP device, but not the drive (See attachment 8). Could someone explain how to properly configure all these settings? Thank you, GA
Last updated: 2023-12-19

Post by aseitzinger on CODESYS Control for Linux SL on virtual machine? CODESYS Forge talk (Post)
Hello, there in different information available regarding the possibility to run CODESYS Control for Linux SL on a virtual machine. https://forge.codesys.com/trg/linux-sl/home/Home/ says CODESYS Control for Linux SL is a runtime system, which can run on any Debian based X86 PC, VM or Cloud container... https://store.codesys.com/media/n98_media_assets/files/2302000005/3/CODESYS%20Control%20for%20Linux%20SL_de.pdf says CODESYS Control for Linux SL can not be used on virtual hardware Currently I run the package mentioned on a virtualized debian machine running in PROXMOX Virtual Environment 7.4-17 and apart from huge jitter it runs without problems. The CODESYS key is passed as a USB defice to the VM. I wonder why there are different statements regarding the suitability in virtual machines and if the jitter would be reduced by installing CODESYS runtime on the host installing CDS runtime on the host and using a preemptive kernel (if available for the PROXMOX installation leaving CDS runtime where it is (on the virtualized debian machine) and install a preemptive kernel on the host and on the guest... Any advice is appreciated. Greets Arno
Last updated: 2024-01-08

Post by axilleas on SMC_Interpolator + SMC_controAxislbyPos CODESYS Forge talk (Post)
dear all I am working on a very generic gantry system (virtual drives + win v3 control) reading gcode from external file. In order to stop the interpolator function from running when gaps are detected, SMC_controlAxisByPos FB has the bStopIpo output which according to the manual is connected to the Interpolator's bEmergencyStop. Lets assume that the axis are parked in position X1000 Y1000 and the initial G code movement is G00 X500 Y500. The normal behavior is to travel from the actual x1000 y1000 to G00 X500 Y500. The SMC_Interpolator always gets the X0 Y0 as the initial position, meaning that the bStopIpo is active until the axis are in X0 Y0 and the release the interpolator to set the new positions to X500 Y500. Is there a suggested method to solve this behavior? bonus question: I get a lot of bStopIpo during standard interpolation movements (not gaps). While working with virtual axis this is not a problem but when real axis are installed this will be an issue. What exactly triggers the bStopIpo output? Slow axis accelerations compare to Gcode defaults? Kind Regards
Last updated: 2024-02-05

Post by alex00 on DCS / Central Engineering with Codesys support CODESYS Forge talk (Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19

Post by alex00 on DCS / Central Engineering for Codesys CODESYS Forge talk (Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19

Post by rjwkerkhof on IIot Libraries SL --> Web Socket Client SL Pong issue CODESYS Forge talk (Post)
Dear all, I am developing a Web Socket Client in Codesys 3.5 using the Web Socket Client SL library to retrieve data from a third party. Connecting and reading works fine however after 40 seconds the connection gets interrupted by the server due to keepalive ping timeout. After discussion with third party it seems that the Web Socket Client SL library replys to the Ping request of the Web Socket server BUT does not add the "Application data" = 4 bytes in the body of the Pingframe to the Pongframe. Therefor the server does not recognize the Pongframe send by the Web Socket Client SL library and automatically disconnects. Is this a known issue with the libary or am I doing something wrong? Is there a workaround to add the 4 bytes manually to the Pongframe before replying it to the server? Thanks in advance, Roy
Last updated: 2024-04-09

Post by rmaas on Fieldbus has lost synchronicity CODESYS Forge talk (Post)
Hi, On a gantry system with 2 axis i am getting the following error: SMC_DI_FIELDBUS_LOST_SYNCRONICITY This happens random, sometimes it happens every 5 minutes and sometimes no error for 2 hours... The Setup: - Using codesys 3.5 SP20 with all latest libs... - Kontron AL Pi-Tron CM4 with Preempt realtime patch (Raspberry Pi 4) - Codesys runtime 4.11.0.0 (single core) - CODESYS Control for Raspberry Pi SL licensed - Softmotion + CNC + Robotics licensed - 2x Leadshine EL8-EC400 servo drives - Axis group for a 2-axis T-Gantry Ethercat network wiring: Ethercat master softmotion -> Beckhoff EK1100 -> Servo drive #1 -> Servo drive #2 Ethercat Cycle time = 4ms Max Jitter = 140~150 What i have tried so far: - changed the sync offset from 20% to 30% - changed ethercat task priority from 1 to 0 Running tasks: - Ethercat tast: Prio = 0, Interval = 4ms - Main task: Prio = 1, Interval = 8ms - Visu task: Prio = 31, Interval = 100ms - Softmotion planning task: Prio = 15, Freewheeling - 3 other default tasks that were created by AC_Persist Motion fb's are called in the ethercat task... Does anyone have an idea how to fix this? Any help is greatly appreciated!
Last updated: 2024-04-11

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by jrsantab on Remote connection to ifm PLC & HMI CODESYS Forge talk (Post)
We have finally solved the problem. The version of the Gateway in the computer that worked (3.5.11.0) and the one that didn't (3.5.17.30) was different. We have three different Codesys 3.5 versions installed because we work with different controllers. I believe that, depending on the sequence you follow to install the versions you get a different Gateway version. To solve the problem you first have to disable the "obsolete" services. Open services, serach for (in our case) CODESYS Gateway V3 Version 3.5.11.0 CODESYS ServiceControl Version 3.5.11.0 I stopped the services and changed to Manual Start. Then you have to create the new services. In our case, from a Command Prompt session (cmd): SC CREATE "Codesys GatewayService Rigual" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\GatewayService.exe" and then SC CREATE "CODESYS ServiceControl Version 3.5.17.30" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\CODESYSControlService.exe" remember also to set them as Automatic Start!
Last updated: 2024-04-22

Post by jose-coro on Trouble installing codesys 64 3.5.19.0 CODESYS Forge talk (Post)
I tried to intalling codesys 64 3.5.19.0, during the installation process I get the following messages: "One or more problems have appeared with the current version profile. please consult with the supplier to solve the problem. -The plugin '{ee08241a-dd43-445a-b0a1-de9f717d92e0}(exactly 3.5.19.0)' is required for the current version profile but is not installed. The plug-in '{c7880c90-68c0-4cf8-a726-f0ee72b11f86}(exactly 3.5.19.0)' is required for the current version profile but is not installed. The add-on '{973a3934-1ec6-4770-83a4-59677803015a}(exactly 3.5.19.0)' is required for the current version profile but is not installed. It is recommended to terminate the application." Then the following message appears: "This package could not be installed: CODESYS Compatibility Package 3.5.17.20”. After that the instalation continue and the folling message appears: "It is possible that packages from this path could not be installed: C:\Users...\Appdata\Local\Temp{EFE2F~1}\Packages"
Last updated: 2024-04-23

Post by jose-coro on Trouble installing codesys 64 3.5.19.0 CODESYS Forge talk (Post)
I tried to intalling codesys 64 3.5.19.0, during the installation process I get the following messages: "One or more problems have appeared with the current version profile. please consult with the supplier to solve the problem. -The plugin '{ee08241a-dd43-445a-b0a1-de9f717d92e0}(exactly 3.5.19.0)' is required for the current version profile but is not installed. The plug-in '{c7880c90-68c0-4cf8-a726-f0ee72b11f86}(exactly 3.5.19.0)' is required for the current version profile but is not installed. The add-on '{973a3934-1ec6-4770-83a4-59677803015a}(exactly 3.5.19.0)' is required for the current version profile but is not installed. It is recommended to terminate the application." Then the following message appears: "This package could not be installed: CODESYS Compatibility Package 3.5.17.20”. After that the instalation continue and the folling message appears: "It is possible that packages from this path could not be installed: C:\Users...\Appdata\Local\Temp{EFE2F~1}\Packages"
Last updated: 2024-04-23

Post by phoward131 on Alarm State Icon CODESYS Forge talk (Post)
I am trying to create an icon on an overview screen that depicts if an alarm group has active alarms, active acknowledged alarms, or inactive unacknowledged alarms (waiting for confirmation). I've attempted to set up Notification Actions in the Alarm Class to set variables based on state changes but have been unable to find a clean and effective way to do this. Because an action on any alarm will trigger the variable to be set as instructed, I'm struggling to find a way to configure it for what I need (ie if two alarms activate, then one deactivates, the variable for indicating an alarm is active would be cleared after the single deactivation). I've been pointed toward the Alarm Manager example project but I'm finding it too complicated to understand how to implement it in my own project. Has anyone come up with another good way to indicate the states of alarms or a simpler usage of the Alarm Manager functions?
Last updated: 2024-04-23

Post by vtec35 on search runtime 4.9.0.0 for pi 3 CODESYS Forge talk (Post)
yes but impossible to upload runtime 4.9.0.0 now we have put an image on the sd card with 4.13.0.0, i have 27 error message to this type, and if i test some output not work, et some work ------ Processus de compilation entamé : application : Device.HiddenOnlineConfigModeApp ------- Affecter un type à un code... [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0032: Le type 'Type inconnu : 'ADR(GVL_Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1.Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1)'' ne peut pas être converti en type 'POINTER TO IoConfigParameter' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0077: Type inconnu : 'GVL_Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1.Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0046: Identificateur 'GVL_Io_73f6cbf3_7be8_4500_8421_47e565d899a0_HPS_1' non défini [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0032: Le type 'Type inconnu : 'ADR(GVL_Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1.Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1)'' ne peut pas être converti en type 'POINTER TO IoConfigParameter' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0077: Type inconnu : 'GVL_Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1.Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0046: Identificateur 'GVL_Io_1b6dcc3b_ae11_4288_b9a9_86f9323448d1_HPS_1' non défini [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0032: Le type 'Type inconnu : 'ADR(GVL_Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4.Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4)'' ne peut pas être converti en type 'POINTER TO IoConfigParameter' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0077: Type inconnu : 'GVL_Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4.Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4' [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj 241025: C0046: Identificateur 'GVL_Io_5ae6fa5a_c197_4038_9581_03e1650806a0_HPS_4' non défini [ERREUR] conditionneuse_camphre-ssa-05-02-24-V3 maj
Last updated: 2025-10-26

Post by bbm1995 on Camera RTSP Feed CODESYS Forge talk (Post)
Hi dgrard, I had the same issue for a long time, but on a WAGO webvisu. Now I'm glad that I can share my solution. I don't know if you are trying to use the webvisu or the target visu, but this works on webvisu: Get "go2rtc" and set it up according to the documentation. I'm running the Windows binary. Here's my example of the go2rtc.yaml config file (contains working example streams): api: listen: ":1984" # default ":1984", HTTP API port ("" - disabled) origin: "*" # default "", allow CORS requests (only * supported) static_dir: "www" # default "", folder for static files (custom web interface) tls_listen: ":443" # default "", enable HTTPS server tls_cert: "./SSL/fullchain.pem" tls_key: "./SSL/privatekey.pem" streams: # Streams with multiple links will fall back on the next link. ABUS TVIP48511: - rtsp://<username>:<password>@<hostname>:<port>/ch1/main - rtsp://<username>:<password>@<hostname>:<port>/ch1/sub # Diagnostic connections Kirchhoff Institute for Physics - Germany: http://pendelcam.kip.uni-heidelberg.de/mjpg/video.mjpg Blanton Bottling, Kentucky - USA: http://camera.buffalotrace.com/mjpg/video.mjpg Tokyo - Japan: http://61.211.241.239/nphMotionJpeg?Resolution=320x240&Quality=Standard Tampere Hacklab - Finland: http://tamperehacklab.tunk.org:38001/nphMotionJpeg?Resolution=640x480&Quality=Clarity Soltorget Pajala - Sweden: http://195.196.36.242/mjpg/video.mjpg Kaiskuru Skistadion - Norway: http://77.222.181.11:8080/mjpg/video.mjpg webrtc: listen: ":8555" #ice_servers: # - urls: [ "stun:localhost:3478" ] # username: "" # credential: "" Access the webinterface of go2rtc and get the link of your stream. Use the link as for your browser frame in the visualization. Depending on your device, you need to be able to access the file /etc/lighttpd/lighttpd.conf or /etc/lighttpd/webvisu.conf and change the contents similar to this one, otherwise you'll get CORS and CSP errors in the browser and you won't be able to view the stream on the webvisu: # Webvisu specific settings $SERVER["socket"] =~ port_webvisu_used_any { url.redirect += ( "^/webvisu/?$" => "/webvisu/webvisu.htm" ) $HTTP["url"] =~ "^/webvisu/?" { var.response_header_policy_webvisu = ( # CSP for WebVisu, allowing inline sources. "Content-Security-Policy" => "default-src 'self' 'unsafe-inline'; media-src *; frame-src *", # CORS for WebVisu, allowing any origin to access. "Access-Control-Allow-Origin" => "*", # Tell older browsers that this page can only be displayed if all ancestor # frames are same origin to the page itself. "X-Frame-Options" => "SAMEORIGIN" ) # Response header policy for WebVisu setenv.set-response-header = var.response_header_policy_webvisu setenv.set-response-header += var.response_header_policy_common }
Last updated: 2023-11-14

Post by gustavocsw on MQTT memory leak problem CODESYS Forge talk (Post)
Hello everyone, I'm using the IoT Library to implement the MQTT communication with my local broker server in order to publish and subscribe at specifics topics to share and consume information about my application. But, it seems that are occurring some memory leak problem in a "high" frequency (more than 10 Hz) subscribe process. I follow the same method as in IoT Lib exemples, and at first looks perfect but my PLC was rebooting frequently and when I check its memory usage that was increasing as fast as the subscribe massage was sent. I'm using a WEG PLC410 and a WEG PLC500, and this error occurred in both of them (including in CODESYS Control Win x64). The application sends to the system a message JSON with the float payload Ex. {"data" : 0.8500}, but this happens with a INT, or BOL as well. I use the follow code in my application to find the value: //FindFirstValueByKey VARs PROGRAM JSON_VELO VAR //------Setting the JSON Subscriber to Set the Relay Value jsonDataVelo : JSON.JSONData; jsonByteArrayReaderVelo : JSON.JSONByteArrayReader; xST1okVelo : BOOL; FindFirstValueByKeyVelo : JSON.FindFirstValueByKey; jsonElementVelo : JSON.JSONElement; xDoneReaderVelo : BOOL; xDoneFindVelo : BOOL; //STRING and WSTRING for Subscribe the massage sPayloadJsonVelo : STRING := 'opa'; psPayloadJsonVelo : POINTER TO BYTE := ADR(sPayloadJsonVelo); //wsPayloadJsonRelaySet : WSTRING := "opa"; wsPayloadJsonVelo : WSTRING := STRING_TO_WSTRING('opa'); pwsPayloadJsonVelo : POINTER TO WORD := ADR(wsPayloadJsonVelo); lrVelo : LREAL; xKeepAliveVelo : BOOL; xSetVelo : BOOL; RSSet : RS; LIMPAR : STRING; //Find the msg end sFindVelo : STRING := '}'; psFindVelo : POINTER TO STRING := ADR(sFindVelo); iLenVelo : INT; iSizeVelo : INT := 12; udiContMsg : UDINT; END_VAR // FindFirstValueByKey CODE // Relay Set configuration xSetVelo := MQTT_SUBSCRIBER.RSVelo.Q1; IF xSetVelo THEN xKeepAliveVelo := TRUE; END_IF IF xKeepAliveVelo THEN udiContMsg := udiContMsg + 1; iLenVelo := TO_INT(StrLenA(psPayloadJsonVelo)); iSizeVelo := iLenVelo - TO_INT(MQTT_SUBSCRIBER.udiPayloadSizeVelo); StrDeleteA(psPayloadJsonVelo,iSizeVelo,iLenVelo); wsPayloadJsonVelo := STRING_TO_WSTRING(sPayloadJsonVelo); pwsPayloadJsonVelo := ADR(wsPayloadJsonVelo); //MQTT.ConvertUTF8toUTF16(sourceStart:= ADR(sPayloadJsonVelo), targetStart:= ADR(wsPayloadJsonVelo), dwTargetBufferSize:= TAM, bStrictConversion:= 1); //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := TRUE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := xDoneReaderVelo, wsKey := "data", diStartIndex:= 0, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); IF xDoneFindVelo THEN lrVelo := jsonElementVelo.value.lrValue; //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := FALSE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := FALSE, wsKey := "data", diStartIndex:= 1, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); xKeepAliveVelo := FALSE; GVL.xSetVeloRead := TRUE; END_IF END_IF And this to subscribe at the topic: //SUBSCRIBE VAR: //----------------- Subscribe Velocity ----------------------- MQTTSubscribeVelo : MQTT.MQTTSubscribe;//Variable MQTTSubscriber block -X - function-X wsTopicSubscribeVelo : WSTRING(1024) := "CORE/odometry/GET/data/simp"; // Topic to publish a message sSubscribeMassageVelo : STRING; udiPayloadSizeVelo : UDINT; xSDoneVelo : BOOL; xSErrorVelo : BOOL; xReceiveVelo : BOOL; eSTypeVelo : MQTT.MQTT_ERROR; eSMQTTErrorVelo : MQTT.MQTT_ERROR; RSVelo : RS; udiCont : UDINT; //SUBSCRIBE CODE: MQTTSubscribeVelo( xEnable:= MQTT_CLIENT.xConnection_Broker AND NOT xSErrorVelo AND NOT JSON_VELO.xKeepAliveVelo, pbPayload:= JSON_VELO.psPayloadJsonVelo, udiMaxPayloadSize:= SIZEOF(JSON_VELO.sPayloadJsonVelo), udiPayloadSize => udiPayloadSizeVelo, mqttClient:= MQTT_CLIENT.ClientMQTT, wsTopicFilter:=wsTopicSubscribeVelo, xDone => xSDoneVelo, xError=> xSErrorVelo, xReceived => xReceiveVelo, eMQTTError=> eSMQTTErrorVelo ); RSVelo(SET := xReceiveVelo, RESET1 := JSON_VELO.xKeepAliveVelo);
Last updated: 2024-09-09

Post by imdatatas on MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0 CODESYS Forge talk (Post)
Hello, I am facing a problem with the new Softmotion 4.17.0.0 version. Has anyone encountered a similar problem, what is the solution? I would be happy if you could share it. Problem description: -- "SMC_FreeEncoder" encoder axis is the master, -- The motor of the servo driver on the EtherCAT bus is the slave axis. -- When the MC_CamIn block executed, the InSync output is activated. However, although the master encoder axis position value changes, there is no movement in the slave servo axis! Test steps: 1-) EtherCAT servo axis installed, configured and motion test was performed with MC_Jog. No problem. 2-) Softmotion general axis pool > SMC_FreeEncoder was added and pulse amount configuration was performed. No problem. 3-) Incremental encoder actual count value was transferred to the "SMC_FreeEncoder.diEncoderPosition" variable as DINT under the ethercat task in every cycle and the encoder axis position value was observed. No problem. 4-) A simple CAM table with a 1:1 ratio was created under the project tree. (For example: Simply, when the encoder rotates 1 turn, the motor will rotate 1 turn.) 5-) The SMC_FreeEncoder axis enabled with MC_Power and brought to the StandStill state. 6-) The MC_CamTableSelect block was run with default input values ​​(all absolute) and only the Cam table name was specified. The Done output was seen successfully. No problem. 7-) The MC_CamIn block was activated with default input values ​​(absolute) and only the master encoder axis name, slave servo axis name, CamTableID input pins was specified and then "Execute" input set to TRUE. 8-) The InSync output information of the MC_CamIn block observed as TRUE. However, although the encoder axis value changed, the position value of the slave axis did not change at all, it did not move. It always remained at 0.0mm. 9-) When I repeated the same steps above, only changing the master axis to SM_Drive_Virtual instead of FreeEncoder and gave movement to the virtual axis, this time the slave axis moved successfully. However, when the same steps and operations are performed with the same IDE just downgrade SoftMotion version from 4.17.0.0 to 4.10.0.0, everything works normally and without problems as expected in MC_CamIn block with FreeEncoder master. (By the way, The used IDE version is Codesys V3.5 SP20patch3.) Best Regards Imdat
Last updated: 2024-11-11

Post by mondinmr on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
In reality, other vendors are already moving towards integration with VS Code. B&R, for example, is likely the only one that could truly challenge Codesys in the market: they’ve overhauled their once-archaic environment (previously lacking ST OOP) and are now catching up significantly with Automation Studio Code, offering modern programming capabilities and native support for tools like Git and GitHub Copilot. The other big names in the market, frankly, are still light years behind. For smaller projects, typically handled by “wire strippers” (with all due respect!), a classic environment might be just fine. But once you’re dealing with thousands or even millions of lines of code—possibly organized in an OOP paradigm, spanning large teams, integrating third-party libraries, requiring version control, and performing comprehensive tests—a lightweight, responsive editor supercharged with AI-based features becomes essential. The real strength of something like VS Code lies in its vast ecosystem of extensions and integrations: from advanced Git support to automated build/test pipelines, and even AI-assisted autocompletion that already makes software development much more agile and productive. I understand that a PLC project involves more than just ST code (task setup, fieldbus configuration, libraries, etc.). However, there’s no technical reason not to at least provide ST files in a pure text format, making version control and collaboration far easier. B&R has clearly adopted this approach; I hope Codesys will accelerate its own efforts to offer a native, text-based integration and modern development tooling. Once you go beyond a certain level of complexity—dozens of configurations, OOP hierarchies, and distributed teams—you really do need “engineer-level” software tools, not just solutions targeting “wire strippers.” For large-scale automation projects, a more open and flexible approach is the only way to avoid chronic frustration. Let me emphasize that I truly love Codesys and consider the work done so far to be brilliant—I’d be sorry to see it overshadowed by others moving faster in this direction.
Last updated: 2025-02-18

Post by jickisticki on Witch library? CODESYS Forge talk (Post)
Crafting my Fellowship Personal Statement was like weaving the threads of my aspirations into a tapestry of words. Each sentence became a brushstroke, painting a vivid portrait of my journey and ambitions. Beyond being just a document, it became a mirror reflecting the depth of my experiences. Like a conductor guiding an orchestra, my personal statement was composed to resonate with my unique voice. In the realm of specialized opportunities, this statement serves as a compass, guiding me toward the next chapter of my professional growth. With each word, I felt the guidance of mentors shaping my story into an eloquent narrative.
Last updated: 2023-08-17

Post by ellcap on Did a library update and now can't open project CODESYS Forge talk (Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25

Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
I'm getting closer to the error. The combination of STRUCT and ARRAY probably causes the strange behavior. As soon as the ARRAY is followed by a variable, the problem arises. Examples: X: ARRAY[1..2] OF INT; // okay Y: ARRAY[1..2] OF STRUCT; // problem Z: STRUCT; Z.ArrayOfInt[1]; // okay Z.ArrayOfStruct[1].Variable // problem // *update - array of array also causes the error A: ARRAY[1..2] OF ARRAY[1..4] OF BOOL; // problem I can't be the only one who has this problem. Or? Maybe there is a solution. Anyone? Or is it a bug after all?
Last updated: 2023-11-17

Post by dkugler on Management of a PLC network from a remote station CODESYS Forge talk (Post)
I would figure out, how to create a simple html webpage with 2 frames. One frame with buttons to select the plc. A second frame with hyperlink to the webvisu of the plc ("XXX.XXX.XXX.XXX:8080/webvisu.htm"). Selecting other PLC Button has to change the hyperlink in 2. frame. Costs only some time to figure out :-) Or setup a raspberry Pi with small visualization. Set up a button for each plc and add one browser element. Each button writes the URL of the depending plc to the URL setting of the browserelement. Costs 55€ for runtime licence and a Raspberry Pi.
Last updated: 2023-12-04

Post by peterned on Programatically restart Codesys OPC UA server? CODESYS Forge talk (Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19