Post by fraccaroli on New Codesys Library Dependencies
CODESYS Forge
talk
(Post)
Hello, you probably fixed in this meanwile, but I think your problem comes from dependencies of other libraries. I see in the Project column of errors the "caa types extern" and "caa fb factory", that both have dependencies. Try to check there. Regards, Francesco
Last updated: 2024-03-21
Post by dekelec on Codesys 2.3 & Peak PCAN
CODESYS Forge
talk
(Post)
IF you have an USB interface type in "Peak_USB" for CAN card driver (Name of CAN card driver). No need to add libraries for communication via CoDeSys Gateway. For other card types contact PEAK support and they will help you. Regards,
Last updated: 2024-07-08
Post by ph0010421 on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
So it's currently mapped to an array of BYTES? Can you create a UNION? TYPE sBytesString : UNION AsBytes: ARRAY[0..127] OF BYTE; AsString: STRING(128); END_UNION END_TYPE Map it to the bytes, read it in the STRING!
Last updated: 2024-09-23
Post by opineiro on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
Thanks, that's what I thought initially. The point is that I can't select a String type variable. See the attached image
Last updated: 2024-09-23
Post by aarondw10 on Use element properties
CODESYS Forge
talk
(Post)
Assume I have a rectangle named rec1 from which I want to use the coordinates of the upper left corner. Is there a way to links these X and Y values from the properties to an integer defined in the main program? Note that I just want to use them and not change any of these coordinates in the program.
Last updated: 2024-02-29
Post by davidbo on Modbus: Is there a way to get the channel index from the channel name?
CODESYS Forge
talk
(Post)
When I use the FUNCTION_BLOCK ModbusChannel I have to sepcify the integer iChannelIndex It can easily go wrong if one has many channels. It would be better if one could use the name. Is that possible? Attached a snippet of the channel name and the channel index to the left.
Last updated: 2024-10-21
Post by opineiro on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
Hi there, I have a Keyence bar code reader connected to my plc through Ethernet/IP. The Bar code is 20 digits long (like 30100790020493036016), the scanner reads it correctly (I can verify that through the keyence software) but when it sends it through ETH/IP, it doesn't fit into a 64 bit variable and it trunks the data.(I've tried ULINT and LWord without success). When I loaded the EDS file, the read variable was defined as a byte with 128 bits length, which is quite strange for me. (see attached picture) How do I manage this variable? Thanks!
Last updated: 2024-09-23
Post by mikek10 on Error IoDrvEthernetIP: Connection Failure. (16#1) How to solve
CODESYS Forge
talk
(Post)
Your connection configuration should look something like the attachment. Consuming assembly O->T will be the hex of the assembly you want to reference for output data - I want 102 (DO Data Only) shown in the Wago web page 102 = 16#66. Producing assembly (T->O) is the assembly you require for input data - again shown in the Wago web page - I want 108 (DI Data Only) or 16#6C Then set the number of bytes as per the data in the Wago web page too (both 2 in my case)
Last updated: 2024-07-22
Post by duvanmoreno24 on Modbus writing on value change
CODESYS Forge
talk
(Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03
Post by ewi04 on Git - User identification data is lost when codesys is closed
CODESYS Forge
talk
(Post)
Hallo, it's not a big problem, but it is a bit annoying. The git user identification data is lost when codesys is closed. So I have to enter the information again and again. Is there a way to save the data? Environment: Codesys V3.5 SP19 Patch 4 (64Bit), Git 1.3.0.0 Thanks
Last updated: 2023-11-22
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by abjha1998 on Converting UINT into bytes and converting 2Bytes into UINT
CODESYS Forge
talk
(Post)
Hi, I have been working on Codesys V3.5 with PFC200 controller and Can Gateway 750-658. I want to convert the incoming CAN data from bytes into UINT and for outgoing data bytes to UINT. Does anyone has experience with this kind of data? I tried few different ways but it doesn't seem to be working.
Last updated: 2023-12-07
Post by nima-khajehali on Data Transferring between 2 PLCs in a same PC
CODESYS Forge
talk
(Post)
Hi Guys, I want to simulate the data exchange between 2 soft PLCs on the same PC. We are trying to simulate the process and we could not see the desired result. What should I do to pass all data between these 2 PLC's correctly ? Please see attached
Last updated: 2024-02-05
Post by dengsberg on Check Connection Status of the OPC-UA Server for Data Source Manager with OPC-UA Client
CODESYS Forge
talk
(Post)
I am using the Data Source Manager with OPC-UA Client to get data from another CodeSys application in the same Project. How can I check in the PLC_PRG structured text if the connection is ok or not?
Last updated: 2024-09-07
Post by timvh on Send data to USB
CODESYS Forge
talk
(Post)
https://forge.codesys.com/prj/codesys-example/file-utilities/home/Home/
Last updated: 2024-07-22
Post by vladimirsmall on Send data to USB
CODESYS Forge
talk
(Post)
Thank you on support
Last updated: 2024-08-05
Post by robbudge on Data Source Error 418
CODESYS Forge
talk
(Post)
Same ? Did you find the Solution??
Last updated: 2024-10-11
Post by ruobian on Analog Input Delay Timer
CODESYS Forge
talk
(Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20
Post by wiresplus on Cannot get INT_TO_TIME working
CODESYS Forge
talk
(Post)
Hello, I have a simple TON timer. It is watching prime loss for a pump. The operator can set the delay via the HMI, it is an integer (seconds) As the TON uses milliseconds, we then multiply the entry by 1000 to get seconds. Seems simple, but... VAR PrimeTimer : TON; primetime : INT; END_VAR PrimeTimer(in:=State>0 AND FlowRate<MinimumFlow,pt:=INT_TO_TIME(primetime *1000)); For an entered 15 seconds (VAR primetime:=15;) the timer reads 49d17h2m26s760ms !!!! What am I doing wrong?
Last updated: 2024-01-26
CSV_Write_read: a sample program for the CODESYS Control WinV3 writing and reading 1000 records of CSV data in a file ...
CODESYS Forge
talk
(Thread)
CSV_Write_read: a sample program for the CODESYS Control WinV3 writing and reading 1000 records of CSV data in a file ...
Last updated: 2023-08-08
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.