Post by androidzz on Json Builder problem?
CODESYS Forge
talk
(Post)
Dear reader, I am using the codesys JSON utilities SL, 1.9.0.0 library. And then specifically the FB JSONBuilder. I need to create a main object with at least 2 objects in it. The first object is no problem, but I cannot insert the second object into the main object. See attached my code and the result I get. I am assuming that I am doing something wrong with the parent index but have tried a lot and can't get it done. Kind regards, Rob
Last updated: 2024-03-11
Post by k4zz on Statisch Code Analyse ausführen via Python
CODESYS Forge
talk
(Post)
Derzeit arbeite ich daran, statische Codeanalyse in unsere (CI/CD)-Pipeline zu integrieren. Konkret habe ich die statische Codeanalyse erfolgreich für .project-Typen durchgeführt, und sie funktioniert einwandfrei. Allerdings habe ich Schwierigkeiten bei der Ausführung derselben für .library-Typen festgestellt. Hierbei habe ich zwei Methoden ausprobiert: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code()
Last updated: 2024-03-18
Post by andy-yemm on Assertion Failed
CODESYS Forge
talk
(Post)
I had similar assertion failed error messages today. I am fairly new to Codesys. I tried using SFC for the first time, I usually use ST. Anyway I had errors in some of my transitions. I copied and pasted transition code and forgot to change the target of the code. I started getting lots of the assertion errors but now I have sorted out the problems and it compiles OK the assertion error messages seem to have stopped. There do not seem to be any other responses to your post, did you resolve your problem?
Last updated: 2024-03-19
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I checked it using the very same docker container version like colleague moon and the command returned root@nt0001c02c5533:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. Result: 0 CmContainer(s) listed. (CodeMeter not running) Please consider that we intend to license a codesys ARM64 SL in a docker container.
Last updated: 2024-03-20
Post by marcolim on RPC failed 0x16c9a085
CODESYS Forge
talk
(Post)
Hello Matteo, I think the problem is about configuration of firewall (windows firewall usually). You can disable temporary the firewall to check if the communication works. Eventually you can: Go to the control panel -> Windows Defender Firewall -> Allow an app or feature Enable the options to change the settings. Scroll down in the application list to CODESYS and CODESYS ControlService. If you don’t see this application add it to the list. Make sure that all the checkboxes are checked (Domain, Private and public).
Last updated: 2024-04-01
Post by schnepper on Error building Extension SDK Linux code
CODESYS Forge
talk
(Post)
I'm installed the CODESYS Control for Linux SL package and am trying to use the Extension API to call a simple C function. When I get to the step to run "make all" on the Linux machine, I get the error: build interface header: out/CmpFirstTestItf.h from CmpFirstTestItf.m4 ERROR: This functionname does not contain _cext (this is mandatory, see help for details): DEF_API(void',CDECL',external_struct__fb_init',(external_struct_fb_init_struct *p)',1,0x1F77E075,0x00000001) Why does "Generate Runtime System Files" create a function that does not have cext in the name? What am I missing?
Last updated: 2024-04-01
Post by sachem on SysFileGetTime problem
CODESYS Forge
talk
(Post)
Good morning. I'm working with a Weidmuller controller using Codesys. My project use OPC-UA to communicate an application in my pc with the controller. Yesterday, I installed the license of the controller and test it, and the communication works perfect. I use the communication with anonymous login, and works fine. But, hours later, the anonymous login don't work, and the controller only allows connection via OPC with username and password. Someone know why this happend? Thanks
Last updated: 2024-04-09
Post by rossanoparis on RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Post)
Hello @rmaas I assume, you've already verified and tuned everything regarding the EtherCAT network. In my case the problem was due to a wrong core assignement. I suggest to not use the core #0 for your EtherCAT task. The OS realtime patch, which is present on RevPi OS, uses the core #0 for its porpouses and it mustn't be used by any other task which requires realtime and deterministic features. regards Rossano
Last updated: 2024-04-11
Post by tk096 on Fieldbus has lost synchronicity
CODESYS Forge
talk
(Post)
Hi, a few suggestions on how to tackle the problem: - it might help to increase the cycle time of the ethercat task - increase the value of the ethercat parameter DCInSyncWindow (https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/pou-IoDrvEtherCAT/DCInSyncWindow.html) (see attached image) - enable FrameAtTaskStart (https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/pou-IoDrvEtherCAT/FrameAtTaskStart.html) in the ethercat master (see attached image) - if the drives can handle the synchronization problems, checking of the synchronization can be deactivated using SMC_Set_ETC_DCSyncSupervision (https://content.helpme-codesys.com/en/libs/SM3_Drive_ETC/Current/SMC_Set_ETC_DCSyncSupervision.html).
Last updated: 2024-04-11
Post by tib0r on c2iec - translating C to ST
CODESYS Forge
talk
(Post)
I was looking for a transpiler from some more widely used general programming language into ST. It was not easy but I found this :) https://forge.codesys.com/tol/c2iec/home/Home/ Does anybody use it for a programm/library of a couple of hundred lines or more? How does one go about using the output? Is there a “converter” into the Codesys IDE? PLCOpenXML? Would there be interest in this? tib0r
Last updated: 2024-04-20
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
I've had issues getting the raspistepper installed, all due to errors upon installation. The closest I get is the pictured error. The functions are in the sm3_shared library. I can add this library but that leaves 2 issues. I don't actually know, and I really want to understand this, why the required dependencies haven't been installed correctly. If I add the library it's only available with through the namespace. What can I do to both understand and resolve this? Thanks edit codesys 64 3.5.20.0 - same error on other versions too sm3 raspi stepper 0.0.0.5
Last updated: 2024-04-20
Post by eschwellinger on License problem gateway
CODESYS Forge
talk
(Post)
I just try to help. Anyway it is a big difference if a Store SL runtime or an oem plc and licence is used. These licenses need to be activated on plc side - so you have dependencies to the version (CODESYS and Runtime Version) Did you ever ask Epis out for this situation? They should know which license fit to their device. Even they should know if the device is capable for Softmotion and see the requiremnts in the CODESYS store: Runtime 4.9.0.0 - how should this work with Epis 3.5.16.x? Anyway refund is not a problem.
Last updated: 2024-04-26
Post by alex2 on Codesys SVN
CODESYS Forge
talk
(Post)
Hello Everyone. I have a question about the SVN module on Codesys. I am using Codesys V3.5.10 and installed Codesys SVN 4.2.5.1 but when i try to connect my SVN to codesys i have a message saying that there is no license for accessing the Url. I searched on the codesys store and it seems that "CODESYS Professional Developer Edition" is needed? Am i right? Do i also need to buy a USB key? Is there another edition but only for the SVN? I thank you in advance for your answers.
Last updated: 2024-04-27
Post by richard-wang on Codesys recipe manager - what does it do?
CODESYS Forge
talk
(Post)
Hi All Thanks for sharing this information. For whom may not know why always get error code 16#4000 or 16#4002 while performing Recipe commands, the root cause is There is a line need to be inserted in CODESYSControl.cfg file, which is PlaceholderFilePath.1=/var/opt/codesys/PlcLogic/ I am using Pi, therefore the above path is set to my pi unit, after adding above line to my cfg file, all the Recipe commands work fine. But I still do not know how and when this file got modified though.
Last updated: 2024-04-29
Post by timvh on JSON
CODESYS Forge
talk
(Post)
I don't know the details of jsonArrayWriter, but the common behaviour for an xExecute input is that the FB starts on the trigger that it gets TRUE. In your case xExecute is never FALSE, so it is never triggered again to start the jsonArrayWriter. So change the condition from TRUE to a variable which you set to TRUE with the "xFirst". Then when the jsonArrayWriter is done (xDone), or has an error (xError), then set this variable to FALSE.
Last updated: 2024-05-01
Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors
CODESYS Forge
talk
(Post)
Update: I started over. I saved progress at each step. all compiled zero errors, zero warnings. Pre-processor messages remain, but I can make progress. Until I try to re- load the project file in Codesys. Re-loaded files error as above when compiled, even though they compiled error-free immediately before saving. Is my installation borked? (Not easy to re-install due to IT madness...)
Last updated: 2024-05-03
Post by fless on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
Why will it retain the sum value from the last call? This is how PLC work. Usually variables only get initialized after a download or a reset (i.e. power loss). RETAIN variables are saved in a special kind of RAM and keep their value after a power loss. To initialize variables on every call of your FB use the VAR TEMP block. VAR_TEMP sum : INT; END_VAR
Last updated: 2024-05-07
Post by miodusy on CODESYS Control Standard S and Beaglebone
CODESYS Forge
talk
(Post)
Hi, CODESYS Control Standard S + CODESYS Visualization L, CODESYS Control for Beaglebone 4.11.0.0, CODESYS V3.5 SP20 + (64-bit) I have problem that license manager say that this device is not supported when i try active whole license. When I select only runtime and communication it is go next step, but then I no have license on in Visualistion section, all of rest of software metric licese is ok(IO, Istances of com et, code size etc.). Thanks!
Last updated: 2024-05-11
Post by engrahman on The current baud rate could not be determined in CR0020 IFM with maintenance tool
CODESYS Forge
talk
(Post)
Hello everyone, im working with IFM CR0020 controller via RS232 protocol where im trying to connect it to my PC but, every time when im using the maintenance tool to identify the device i get the error "The baud rate could not be determined" i have tried to change the cable of RS232 with different types but the error presist, any idea how to fix it
Last updated: 2024-05-21
Post by hjohnson123 on Automatically selecting a visualization element
CODESYS Forge
talk
(Post)
I'm looking to automatically select a text field element in my visualization. I'm not sure if this is possible, as I don't know how to get the data on specific elements. I am wanting automatic selection of the text field, as I am using a keyboard-input barcode scanner, which should always input the barcode into the text field whenever a barcode is scanned. Does anyone know if this can be done?
Last updated: 2024-05-21
Post by esave on Softmotion Axis Controll
CODESYS Forge
talk
(Post)
Hello everybody I have two of these EtherCat CiA402 stepper driver from Leadshine: https://www.leadshine.com/product-detail/EM3E-556E.html I want to controll them. I already have implemented them in Codesys with Softmotion. I see the position, the velocity and the status word so I can read everything. See picture 1. But when I want to write something like MC_Power or MC_MoveAbsolut with the SM3_Basic library it wont work and with the MC_Reset POU it shows: "SMC_R_DRIVE_DOESNT_ANSWER". See picture 2. Can somebody help me? Thanks a lot esave
Last updated: 2024-05-24
Post by wiresplus on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
Hello, I have a counter that increments an INT value once per minute I want to display this value in Minutes until 60, then Hours/Minutes thereafter on the HMI Codesys V3.5 SP16 I can divide the minutes by 60 to get hours, but then the minutes is still more than 60. Example: a process has run for 350 Minutes. I need to display "5 Hours 50 Minutes" But if it's only been 45 Minutes, I don't want "0 Hours 45 Minutes" , just "45 Minutes"
Last updated: 2024-05-25
Post by plunje on Sensor not set
CODESYS Forge
talk
(Post)
A got a larger project but this very small example makes it clear. I have a button, and after it's clicked a lamp should flip on and stays on, and when the mouse-button is released it should stay on. When I try that in the PLC_PRG it works, but when I change it to a function block (seet attched demo proj) it isn't. I'm fairly new to PLC programming but are very experienced C# engineer, but this goes above my head...
Last updated: 2024-05-26
Post by paro on send appliaction files to wago plc (codesys 3.5) via ssh
CODESYS Forge
talk
(Post)
Hi, it is enough to copy the files to /home/codesys/PlcLogic/Application and adding the lines [CmpApp] Application.1=Application to the eRUNTIME.cfg, if your Application in your program is also called "Application". Reboot -> Bootapp should be loaded. If not please check the log /var/log/runtime.log There should be a line which explains why the bootproject is not loaded.
Last updated: 2024-05-29
Post by greenwood on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline
CODESYS Forge
talk
(Post)
Hallo, und vielen Dank für die Antwort. Ich habe 'Modbus_Slave_COM_Port' in eine Watchliste genommen. Leider reichen meine Kenntnisse nicht aus, um aus dem Ergebnis irgendwelche Schlüsse zu ziehen. xBusy und xError wechseln zwischen true und false (im Gegentakt), der angezeigte Fehler ist 'Response Timeout'. iChannelIndex wechselt zwischen 0 und -1. Wenn ich das richtig verstehe bedeutet das wohl, das der Servotreiber auf Anfragen einfach nicht reagiert. Ich hänge einen screenshot vom Watchfenster an, vielleicht kann jemand mehr herauslesen als ich. Nochmal danke fürs Lesen und Überlegen!
Last updated: 2024-05-31