Post by valenting on Runtime not working on raspberry pi Bullseye
CODESYS Forge
talk
(Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?
Last updated: 2024-03-01
Post by i-campbell on build (F11) / generate code using a python script file
CODESYS Forge
talk
(Post)
hello, please enjoy. # i-campbell 2024 import subprocess from scriptengine import * # with a project already open # save if not yet saved # check pool objects if it is a library # generate code only for the active application if it is a project # beep thanks to https://devblogs.microsoft.com/scripting/powertip-use-powershell-to-send-beep-to-console/ if projects.primary: # check project is open if projects.primary.dirty: # save projects.primary.save() if projects.primary.path.lower().endswith('.library'): projects.primary.check_all_pool_objects() # check all pool objects for lib else: projects.primary.active_application.generate_code() # generate if not lib # note, there could be more applications than the active application, # this script does not generate those else: system.write_message(Severity.Error,'no project open') ps_output = subprocess.check_output(["powershell", "-Command", "[console]::beep(500,300)"]) # beep
Last updated: 2024-04-10
Post by pernockham on Images not shown in webvisu
CODESYS Forge
talk
(Post)
Two issues. Ive been struggling to get the user management the way I want it. I want to protect the device from unauthorized upload/download, but I do not want login requirement on webvisu. The combination that seems to work is to use "runtime device user management" while keeping the visu user management in "legacy mode"? Initially this seemed to work, but now images are not loaded when using direct access, while they are still shown if I access the webpage via Automation server. Im guessing its connected to the authorization changes? Anyone able to help out? Thanks Also, I read that legacy mode should be avoided, is it possible to use "runtime based visu user management" while keeping direct access to the webpage without login. System is a "Control for linux SL, version 4.20.0.0" Per
Last updated: 2026-04-10
Post by mariusz997 on Visualisation - internal error
CODESYS Forge
talk
(Post)
Hi everyone. I try to reach Codesys but I have problem on the beginning. I use Codesys 3.5.18.60 and 3.5.18.30 . On both version I have this same problem - when I create new standard project with controller Control Win v3 x64, empty PLC program - I compile it and everything is ok. But when I add visualisation without any elements and compile it - I get: ~~~ ------ Build started: Application: Device.Application ------- Typify code... Generate code... Generate global initializations... [WARNING] SortingStation: HMI Device: PLC Logic: Application: Missing element configuration. Element may not be usable. [WARNING] SortingStation: fbOutletConveyour Device: PLC Logic: Application: C0196: Implicit conversion from unsigned Type 'WORD' to signed Type 'INT' : Possible change of sign [ERROR] Internal error:System.NullReferenceException: Odwołanie do obiektu nie zostało ustawione na wystąpienie obiektu (in english: Object reference not set to an instance of an object.). w _3S.CoDeSys.Codex86_64.V351500.CPUx86_64.CodeStore(TypeClass tc, Register RegBase, Register RegIndex, Int32 nOffset, Register RegSrc, Int32 nScale) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.GenerateVarAbsolut(IVariableExpression varexp, Int32 iArea, Int32 nAddress, IIndexInfo indexinfo, ICompiledType ctype, Int32 nTypeSize, IAccessMode am) w ..(_IVariableExpression ) w ..(IExprement ) w ..(IExprement ) w ..(_ICompoAccessExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IAssignmentExpression assign) w ..(_IAssignmentExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IExpressionStatement expstat) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, ISequenceStatement mainRoutine, Boolean bKeepCompileInformation, IEnumerable`1 subroutines) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, Boolean bKeepCompileInformation) w ..(_ICompiledPOU ) w _3S.CoDeSys.Compiler35180.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) w ..(_ICompiledPOU , Boolean , Boolean , _ICompileContext , _ICompileContext , Boolean , Codegeneration , Boolean& , Boolean , Boolean ) w ..(Boolean , Boolean , _ICompileContext , _ICompileContext , InitExitSignatureInfo , Boolean , Codegeneration , _ISignature , Boolean& , Boolean , Boolean ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature , InitExitSignatureInfo& , Boolean& ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(ICodegenerator ) w ..() w ..() Build complete -- 1 errors, 2 warnings : No download possible ~~~ Could someone help me with this problem? Thank you in advance Mariusz
Last updated: 2025-11-11
Post by serwis on Dynamic target position tracking
CODESYS Forge
talk
(Post)
Hello, I am trying to control a servo drive and dynamically set its position. I control the drive via EtherCAT with a cycle time of 500us. I use the MC_MoveAbsolute block for this. The problem is that when using a PID controller, I generate the positions I want the drive to move to on an ongoing basis, and I would like the position to be set immediately. The MC_MoveAbsolute block must receive a rising edge to execute, and I would like the movement to be performed without waiting for this edge. I have created a function that generates a rising edge every 1 ms, but I am unable to change this time to 500 µs because the TON function does not support times shorter than 1 ms. Below is the code to call the rising edge: IF Exe = TRUE THEN delay1(IN:=TRUE, PT:=T#1MS); IF delay1.Q = TRUE THEN Exe := FALSE; delay1(IN:=FALSE); END_IF END_IF IF Exe = FALSE THEN delay(IN:=TRUE, PT:=T#1MS); IF delay.Q = TRUE THEN Exe := TRUE; delay(IN:=FALSE); END_IF END_IF END_IF Here is the code for calling the MC_MoveAbsolute function: MoveDegree( Axis:= Tilt, Execute:= Exe, Position:= position_target - (base_angle_real * feedforward_turn), Velocity:= vel, Acceleration:= acc, Deceleration:= dec, Jerk:= jerk, Direction:= MC_DIRECTION.shortest, BufferMode:= MC_BUFFER_MODE.Aborting, Done=> , Busy=> , Active=> , CommandAborted=> , Error=> , ErrorID=> ); I realize that there are probably better methods for performing this type of task. How can I implement motion with a dynamically changing setpoint? THANKS
Last updated: 2025-09-05
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by timvh on ernesto881124
CODESYS Forge
talk
(Post)
You will need a USB to RS485 converter to connect the PC to the Modbus RTU Slave Device. In Windows this converter will be recognized as Serial COM poort (e.g. COM2, or COM3, see the windows device manager to find this out). Select this port in your CODESYS application. On the PC you need to use the CODESYS Control Win (SoftPLC) to run your application. It will not work in simulation mode, because then the Modbus Communication will not be activated.
Last updated: 2023-09-14
Post by vformanek on OPCUA Datasource, can not login...
CODESYS Forge
talk
(Post)
Hello? I have a problem with datasource... I am trying to connect to a OPCUA server. I create a datasource, but I can not login into it. I need to use login credentials to login... Everything works fine in UAExpert, but in codesys I cant seem to get in properly using the login credentials... I have tried to configure the datasource initializer but seem to keep failing... Do I need to call it somewhere ? Will the find endpoints work with this configured to store my password ? !
Last updated: 2023-11-20
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by thn-power on Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Post)
Hi. Thanks for the answer. I think I found your post on the Wago forum. I have tried installing all different nodeset versions of the opcfoundation.org/UA but neither work. Though I could not find the nodeset version called 15.09.2021 anywhere online. The opcfoundation repository only goes back to version 1.04.11 2022-03-29. Also wondering how I can generate a custom information model that only refrences the latest version of nodesets?
Last updated: 2024-09-19
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by mascara on TouchScreen does not work in Webvisualization.
CODESYS Forge
talk
(Post)
I am configuring a Lenovo M900 computer with CODESYS Control RTE SL 3.5.20.30. I use an Aoc E2272pwut LED 21.5 monitor. The touchscreen works perfectly in the Windows 10 PRO environment but does not work in the WebVisualization environment (Window opened at PLC startup). Does anyone know if it is necessary to configure any drivers in Win RTE? I am at your disposal for any questions. Thank you.
Last updated: 2024-11-11
Post by selim on Need help to get RS-485 signal in Cosesys .
CODESYS Forge
talk
(Post)
Hello Mr./Ms., I invested Raspberry Pi lot of time to get the output from the raspberry PI5. But, i did not get the signal. I use a raspberry pi 5> RS485 can hat > Modbus RTU, Industrial 8-ch analog acquisition module >weight transmitter jy-s60> S-load cell. I did not able to receive the signal from Modbus RTU to Raspberry PI5 where I use the RS 485 serial connection.
Last updated: 2024-12-01
Post by smartcoco on Opaque NodeId in the OPC UA server
CODESYS Forge
talk
(Post)
This seems to be because when creating 'OPC UA' with 'Communication Manager', the 'IdentifierType' of 'NodeId' cannot be configured as' String 'type. This issue is not an isolated case. For this issue, CODESYS seems to have not provided guidance to users on how to proceed. We can provide feedback on this issue in the 'My Question' section of the 'CODESYS Store' to make CODESYS take it seriously.
Last updated: 2025-01-10
Post by rmaas on STRING conversions to DWORD
CODESYS Forge
talk
(Post)
Hi, The '' characters in Codesys are there only to indicate it is a STRING type. They are not actually added to the string, maybe you are adding them unintentionally in the concat function? You can send your data from Codesys to Hercules to verify... Another option is to send the data as an array of bytes instead of a string, with every byte representing 1 ASCII character. https://www.ascii-code.com/ This way you are 100% sure Codesys is not adding any unwanted characters.
Last updated: 2025-01-31
Post by imdatatas on TO_STRING operator not working for IMPLICIT ENUM
CODESYS Forge
talk
(Post)
Hi Everyone, It is a very useful feature to be able to obtain the enum value as a string with the TO_STRING operator by defining {attribute 'to_string'}. However, unfortunately the same function does not work for IMPLICIT ENUMs. I hope that {attribute 'to_string'} behavior can also work for Implicit Enumeration data types in one of the upcoming Codesys versions. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_to_string.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_implicit_enumeration.html Best regards, Imdat
Last updated: 2025-03-27
Post by sercan on Does G75 work when SMC_NCInterpreter is used?
CODESYS Forge
talk
(Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09
Post by sercan on Does G75 work when SMC_NCInterpreter is used?
CODESYS Forge
talk
(Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09
Post by sercan on Does G75 work when SMC_NCInterpreter is used?
CODESYS Forge
talk
(Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09
Post by sercan on Does G75 work when SMC_NCInterpreter is used?
CODESYS Forge
talk
(Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09
Post by sercan on Does G75 work when SMC_NCInterpreter is used?
CODESYS Forge
talk
(Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -