Post by corriibme on JSON Utilities and SetArray CODESYS Forge talk (Post)
Hello @florian, Could you please help with how to set an array value? I've been trying to use the with the setKeyWithArray method which creates the key with an empty array value. But I have been unable to set items in this array? objindex:= fb_JBuilder.SetKeyWithArray("Key6", diParentIndex := diRootIndex); objindex2:= fb_JBuilder.SetValue(value:= iValue2, diParentIndex:= objindexx); //iValue: array[0..n] of int; Best regards
Last updated: 2024-05-11

Post by k2saki on How to define CONDITIONAL PRAGMA that effects all ST-POU in project. CODESYS Forge talk (Post)
I'd like to use same code/project in different devices. (RPi, PLC) I change some lines in some POU before compiling. (array size, file path, etc ) My question is How to define pragma that effects all ST-POU in project. Is it possible ? I've read this. https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_pragma_conditional/
Last updated: 2024-05-12

Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux CODESYS Forge talk (Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13

Post by mani-i4point0 on CODESYS Development System V3 ( 3.5.19.70 ) on Windows Virtual Machine CODESYS Forge talk (Post)
Hi, I have a requirement where in need to install a CODESYS Development System V3 ( 3.5.19.70 ) on a Window 10 which is running in VM. Is there any limitation of functions and features of using CODESYS Development System V3 ( 3.5.19.70 ) installed in Window 10 which is running in VM. Please do advice. Best Regards, Mani
Last updated: 2024-05-14

Post by mani-i4point0 on CODESYS Development System V3 ( 3.5.19.70 ) on Windows Virtual Machine CODESYS Forge talk (Post)
Hi, I have a requirement where in need to install a CODESYS Development System V3 ( 3.5.19.70 ) on a Window 10 which is running in VM. Is there any limitation of functions and features of using CODESYS Development System V3 ( 3.5.19.70 ) installed in Window 10 which is running in VM. Please do advice. Best Regards, Mani
Last updated: 2024-05-14

Post by micik on CAA File- FILE_OPERATION_DENIED error CODESYS Forge talk (Post)
Hello, I'm trying to use FILE.Open to open file that exists in the given location. sFileName is formed from "Copy as path" in Windows. So I'm sure file exists and it is in the given location. And still, I get thiss denied error. What could be the problem here? Attached is a screenshot with current implementation.
Last updated: 2024-05-16

Post by kumareasu on Persistent variable storage CODESYS Forge talk (Post)
Is there any function function block which can store the persistent variable in HDD/SSD immediatley. My observation is that the persistent variable is getting stored when we shut down or restart the system (Windows+ CoDeSys RTE SL ). the persistent variables are not stored in HDD/SSD, if I power off the system without proper shutdown. Seeking your feedback.
Last updated: 2024-06-12

Post by andreag0 on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
Hello, anyone know how to get valiable value using a symbolic string name? For example: - send string to runtime using TCP/IP contains "GVL.TestINT" and get back the value. I need function that will translate the string to symbolic variable. Thank you. Andrea
Last updated: 2024-06-13

Post by koppit on SysComRead Timeout Parameter CODESYS Forge talk (Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26

Post by josealb2000 on EL6910 as a PROFIsafe F-Host in Codesys CODESYS Forge talk (Post)
Interested. I can see the EL6633 Profinet Controller can be added in Codesys to the EK1914 or EK1100, and then ProfiSafe devices can be added as the F-DI8/F-DQ3 ET200eco PN. Im unsure how to configure the telegram to the EL6910. Have you been able to make this configuration? EL6910 Manual shows a way but only using TwinSafe.
Last updated: 2025-10-23

Post by snguyen on Any ways to prevent Infinite scroll when moving an object to the left or top edge? CODESYS Forge talk (Post)
I've been making few HMIs and I'm starting to get annoyed that whenever I try to align an object to the left or top side of the frame, it quickly scrolls into that direction infinitely. Is there a way to prevent that?
Last updated: 2025-10-24

Post by fahrettin on CODESYS 3.5.17.30 Setup Error CODESYS Forge talk (Post)
While trying to install CODESYS 3.5.17.30 (64-bit) on my Windows 11 computer, I'm getting the errors below. The first error occurs near the end of the installation. Once you bypass it, the installation returns the second error. Do you have any suggestions for a solution? By the way, I've tried this on several PCs, but I haven't found a solution.
Last updated: 2025-10-30

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hello, Basically, everything is clear to me. There's still the issue of a TimeProvider for an external device. This may be a stupid question, but I can't find this package. And of course, the question is, can the RPi machine be an external provider? Has anyone tested such a solution?
Last updated: 2025-11-18

Post by gseidel on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Hi bertus, thanks for the additional information. Setting bAbort on a restart is not needed. Calling all FBs starting from the decoder up to checkvelocities with bExecute = FALSE and then giving a new rising edge on bExecute is what should be done. Do you also restart the Interpolator? (I don't think that has anything to do with the issue, but still...) Best regards, Georg
Last updated: 2025-12-23

Post by blitz on SMC_ERROR SMC_CGR_INVALID_POSPERIOD CODESYS Forge talk (Post)
Codesys - SMC_ERROR SMC_CGR_INVALID_POSPERIOD - Invalid modulo period less than or equal to zero or greater than half the bus bandwidth. Has anyone seen this error and actually understands what it means and how to get rid of it? I tried to work around it by reducing the number of increments on the drive but then the drive itself starts throwing errors.
Last updated: 2025-12-15

Post by mascara on CloseTargetVisu CODESYS Forge talk (Post)
I need to add a button to the Visualization to close it. And create a shortcut on the Windows desktop to reopen the Visualization. This is necessary to configure, for example, a local IP address. Is this possible? What command closes the Visualization? Which program opens Visualization? System: Win10 Codesys: Control RTE V3 x64 Program: Codesys V3.5 SP20 Using only a touchscreen monitor, without keyboard and mouse.
Last updated: 2026-03-11

Post by bdschnapp on OPC-UA ApplicationUri / ProductUri CODESYS Forge talk (Post)
From Codesys support: The format of the URN is always the same. It's always urn:<vendor>:<product>:OPCUA:Server. What I think you can influence the vendor and product (DeviceName) through settings in the runtime cfg file:</product></vendor> [SysTarget] VendorNameUnicode="T\00E\00S\00T\00" DeviceNameUnicode="t\00e\00s\00t\00" Note that these are 16-bit strings, thus the ASCII padded with nulls
Last updated: 2026-03-17

Post by petra on Gateway not configured properly when read_online_value CODESYS Forge talk (Post)
Here is what I use to read online the parameter value. proj = projects.primary app = proj.active_application plc = proj.find("Device", True)[0] onlineapp = online.create_online_application(app) onlineapp.login(OnlineChangeOption.Try, True) dev1 = proj.find("DEV1", True)[0] for conn in dev1.connectors: > parms = conn.host_parameters > if len(parms) > 0: > p = parms.by_id(1074855985) > p.read_online_value(2000) ---> error: Gateway not configured properly
Last updated: 2026-06-12

Post by petra on Gateway not configured properly when read_online_value CODESYS Forge talk (Post)
Here is what I use to read online the parameter value. proj = projects.primary app = proj.active_application plc = proj.find("Device", True)[0] onlineapp = online.create_online_application(app) onlineapp.login(OnlineChangeOption.Try, True) dev1 = proj.find("DEV1", True)[0] for conn in dev1.connectors: > parms = conn.host_parameters > if len(parms) > 0: > p = parms.by_id(1074855985) > p.read_online_value(2000) ---> error: Gateway not configured properly Does anyone know about this?
Last updated: 2026-06-12

Post by erik-gerrits on Dynamic Images CODESYS Forge talk (Post)
I ran into this issue as well. Here is the fix: Good example: CASE iBitmap OF 0 : sName := 'ImagePool.image0'; 1 : sName := 'ImagePool.image1'; END_CASE Bad example (this will only work on the target device, WebVisu will show a blank rectangle): CASE iBitmap OF 0 : sName := '/home/cds-apps/PlcLogic/visu/image0.png'; 1 : sName := '/home/cds-apps/PlcLogic/visu/image1.png'; END_CASE
Last updated: 2026-07-10

Post by wold on CodeMeter Network Server: Keep runtime dongle local-only and export only a second CmStick CODESYS Forge talk (Post)
Hello, I am running a CODESYS Control Runtime on a Raspberry Pi. Two CmSticks are connected to the same system: CmStick A - Runtime license - MultiCore license - KNX license CmStick B - Engineering / Developer licenses My goal is: The runtime on the Raspberry Pi shall use CmStick A locally. Licenses from CmStick A shall NOT be provided by the CodeMeter Network Server. Only licenses from CmStick B shall be available to remote network clients. During troubleshooting I observed that the CodeMeter Network Server collects licenses from both CmSticks. The KNX license appears to be local-only, but the runtime and multicore licenses of the same dongle are still visible through the server. I would like to know if a supported configuration exists for the following scenario: One CmStick remains strictly local to the runtime. A second CmStick on the same machine is exported through the CodeMeter Network Server. Questions: Is it possible to exclude a specific CmStick from being exported by the CodeMeter Network Server? Can this be configured via License Access Permissions (ACL), WebAdmin, or another mechanism? Can export rules be applied per CmStick, per Firm Code, or per Product Code? If supported, could you provide a configuration example or a reference to the relevant documentation? The reason for asking is that after removing a separately installed CodeMeter server component and returning to a local-only setup, the runtime licensing behaviour became stable again. Therefore I am looking for the officially supported way to keep the runtime dongle local while still providing engineering licenses from a second dongle over the network. Thank you.
Last updated: 2026-08-02

Post by kambel on IO Drive on C manual CODESYS Forge talk (Post)
Hello, pls help!!! Is there a more detailed manual (for dummies) for writing your own IO drive device in C? Another question: how can I add diagnostics to the IEC IO Drive device so that a red triangle lights up in the project tree in the event of a malfunction?
Last updated: 2026-01-29

Post by gatto on EXCEPTION [watchdog] how to find position cause CODESYS Forge talk (Post)
hi. My plc is weidmuller UC20-WL200-AC, IDE CODESYS 3.5.20.40, see picture for task settings. sometime i've got the plc stop. Reading the log, I find: EXCEPTIONPOSITION : IP=0x(nil) (no IECcontext could be retrieved) component CmpIecTask EXCEPTION [Watchdog] occurred: App=[Application], Task=[TASK_O_MAIN] component CmpIecTask How to find the position of problem?
Last updated: 2026-02-06

Post by reinier-geers on Compare applications in one project CODESYS Forge talk (Post)
HI,ive got one project with 6 applications. one master and 5 slaves. All 5 slaves should be the same. Can i compare applications in one project ? sind version 20.5 ive got problems. One slave freeze compleetly after a while. Ive got an other project freezes after a while , after a online change
Last updated: 2026-03-19

Post by reinier-geers on Compare applications in one project CODESYS Forge talk (Post)
Ive copied slave 3 to slave 1. Runs without a problem. Then i copied 1 to 3. It hangs/freeze immediatly. not even a screen. Only thing that is diverend is the network variable. What is the problem with version 20.5 / 21.0 ? Not even my dealer knows whats the problem
Last updated: 2026-03-19