Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Ok, with debug you suppress the errors, but that doesn't help you any further. You can find information about the missing drivers here https://forge.codesys.com/forge/talk/Runtime/thread/8981ce928a/ and here https://github.com/stefandreyer/I2C-Multiplex I'll have to have another look at which library you need. But you can easily find out. Create a completely empty project and insert the TCA9548. You don't need the board. Then look in the library and resolve all conflicts If you can compile the project without errors, delete the TCA9548 and insert the ADS1115. The driver should then also run. Small bonus: with the TCA9548 you can expand your network as you wish and use identical sensors multiple times
Last updated: 2024-11-08

Post by fless on How to change bHiresMode CODESYS Forge talk (Post)
you need to set the increments to 10 (the screenshot shows 10000 hex = 65536). all the turn settings to 1. and the application units to 366. But usually you use the resolver resolution per motor turn. Insert the gear ratios (1:1 for no gear) and the last field you put the circumference of your drive wheel.
Last updated: 2024-03-12

Post by xabier on See only variable CODESYS Forge talk (Post)
I have declarated this variable...When i use the variable I see all...I wan see only the variable not all. For example I declarated in GVL_GLOBAL ==> Torque_Mode When I push enter insert in code all rute..GVL_GLOBAL.Torque_MOde...I want see only torque mode...How is possible resolved this problem?? Thanks XABI
Last updated: 2024-03-14

Post by k2saki on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment . CODESYS Forge talk (Post)
Hi, gseidel. Thank you so much for your advice. I have created a program to preprocess G-code as follows 1.SMC_ReadNCFile2 2.SMC_Interpreter 3.SMC_CheckVelocities Then I put SMC_OUT_QUEUE in SMC_Interpolator. Where should I insert SMC_SmoothMerge and SMC_SmoothPath? Or are there any example link for it ?
Last updated: 2024-04-30

Post by simotion on Inheritance of axis CODESYS Forge talk (Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07

Post by apurv on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07

Post by sturmghost on Visualization using methods and cyclic ST-calls CODESYS Forge talk (Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.
Last updated: 2024-01-22

Post by micik on CAA File, how to check whether file exists or not CODESYS Forge talk (Post)
Hello, what would be the most efficient way to check whether the file exists or not. I don't want to use file.Open function, it seems like rather inefficiet operaton. I considered GetAttribute function, but this function doesn't accept filename (with path) as an input. Basically I need to check first time when program is loaded to the runtime i.e. when application is started for the first time, whether a file exists on the specific location or not.
Last updated: 2024-05-16

Post by i-campbell on Ping By Name CODESYS Forge talk (Post)
https://content.helpme-codesys.com/en/libs/Net%20Base%20Services/3.5.19.20/NetBaseServices/Function-Blocks/IP/fld-IP.html resolve hostname and ping?
Last updated: 2023-08-24

Post by smartcoco on Visualization using methods and cyclic ST-calls CODESYS Forge talk (Post)
I think what you want is a declaration period function for the page, but unfortunately CODESYS does not have it.
Last updated: 2023-10-17

Post by jerry-sorrells on Find Function: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Build: CODESYS 3.5 SP19 Patch 1 (64-bit) Host OS: Windows 10 Target: Linux SL I have a project with programs in Structured Text and Ladder Diagram. When I try to use the Find function, it works for the Active Editor; however, when I try to use Find for the Entire Project, I get the error "Object reference not set to the instance of an object." I know what this error means in the context of the program, but I have no idea why the find function is returning this error. The variable I am searching does not matter: it happens with all variables. Any help with this will be greatly appreciated. I generally use the Find function quite often as I am developing and not having it is really slowing me down.
Last updated: 2023-10-23

Post by pascaljt on Function block for Ethernet/IP CODESYS Forge talk (Post)
Hello, I program a function for an Ethernet/IP controller. I made a structure with input and output corresponding with the map of my controller for the function block. My problem is that I don't know how to do the link between the controller and my PLC (CC 100 from Wago). The addresses declare in Codesys are illogic, The first addresses are 12 and 13 then 7 then 4. How to do corresponding the addresses of the controller and the input / output structure ? IP adress ? Does I must create the all variables of controller with the controller adresses to use with the function block ? Thanks for your help. (I hope I'm clear, I'm not english)
Last updated: 2023-10-26

Post by tk096 on Axis_Ref_SM3.perfTimers CODESYS Forge talk (Post)
Hi, these variables are internal members of the axis. They measure the duration of some internal function calls.
Last updated: 2023-11-23

Post by user3000 on Can't find an Extended Pulse Timer (TP and LTP) CODESYS Forge talk (Post)
I came up with an FBD that seems to be working, although it may not be a true Retriggerable Pulse timer. There may be some delay associated with the two MOVE functions and ADD function I incorporated. I'd be interested if anyone is able to come up with something cleaner. I am surprised that this is not a built-in function block of the CodeSYS library. This is a common feature of multi-function timer relays. I also attached a page from the cut sheet of a Schneider relay that shows 10 timing functions. Looks like the CodeSYS library has built-in function blocks for only 3 of the 10.
Last updated: 2023-12-21

Post by totorovic on How to display the application name on a visualization (V3.5.16) CODESYS Forge talk (Post)
You could use the function AppGetApplicationInfo from CmpApp library. https://content.helpme-codesys.com/en/libs/CmpApp/Current/AppGetApplicationInfo.html
Last updated: 2024-05-14

Post by timvh on Display minutes as hours & minutes CODESYS Forge talk (Post)
You could use the Modulo function to get the minute part from the total minutes: Minutes := TotalMinutes MOD 60;
Last updated: 2024-05-27

Post by timvh on Sensor not set CODESYS Forge talk (Post)
Your function block instance is not called, so the code is not executed to set the light on when the button is pressed.
Last updated: 2024-05-27

Post by eguerra on Error in ScriptingEngine Docs - create_pou() CODESYS Forge talk (Post)
In the ScriptingEngine documentation there seems to be an error (or missing information) in the ScriptIecLanguageObjectContainer part ( https://content.helpme-codesys.com/en/ScriptingEngine/ScriptIecLanguageObjectContainer.html#ScriptIecLanguageObjectContainer.ScriptIecLanguageObjectContainer ). The description of the function create_pou() doesn't specify the correct arguments requested, it only says create_pou(type: SpecialPouType) and a script using the documentation definition of the function will raise an error. I tried passing the function arguments similar to the ones specified for the create_dut() function and it seems to work fine: create_pou(name, PouType) , name : str UPDATE: The offline help has the correct definition IExtendedObject<IScriptObject> create_pou( string name, PouType type = PouType.FunctionBlock, Nullable<Guid> language = null, string return_type = null, string base_type = null, string interfaces = null )
Last updated: 2024-08-05

Post by tk096 on SMC_NCDecoder very slow to decode lines CODESYS Forge talk (Post)
Hi, you can call the decoder function block in a loop and/or decrease the task cycle interval of Task_PATH.
Last updated: 2024-08-23

Post by opineiro on Stack overflow with really simple function CODESYS Forge talk (Post)
Thanks, I'm going to rework everything with this in mind.
Last updated: 2024-09-23

Post by tvm on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
maybe this would be a better approach, then you don't have to pass the constant at all. FUNCTION fun : INT VAR_IN_OUT arr: ARRAY[*] OF INT; END_VAR VAR lower: DINT; upper: DINT; END_VAR lower:= LOWER_BOUND(arr, 1); upper:= UPPER_BOUND(arr, 1); see here as well https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_datatype_array/
Last updated: 2024-01-08

Post by tvm on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
It will be a reference, because it's a VAR_IN_OUT. it's a little weird debugging the array online. It just shows as a POINTER TO INT, and you can't actually see the array from the function side. But you can still work with it as a normal array, not a pointer.
Last updated: 2024-01-09

Post by scarter on Bit / Bool data types in function parameters CODESYS Forge talk (Post)
Any reason BIT and BOOL data types are not interchangeable? Trying to make a function which takes a BOOL IN/OUT parameter (Not allowed to use BIT) In the main logic if I make a DINT variable, and want to use each bit on different functions CODESYS will not allow it.
Last updated: 2024-01-17

Post by timvh on Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06

Post by siscu on Raspberry Pi: List of available example applications CODESYS Forge talk (Post)
Could this be turned into a library? I'd love for a way to have the main program call a function block method using the program's I2C_master device. I assume I should be passing the master as a variable for the function block, but I don't see how that could be achieved