Search talk: type convert

 
<< < 1 .. 12 13 14 15 16 > >> (Page 14 of 16)

Post by francescoc on Logger in ms CODESYS Forge talk (Post)
Hi, I cannot find any documentation regarding the codesys configuration file. I modified this part to have log files saved to disk: [CmpLog] Logger.0.Name=LOGS/PlcLog Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=20000 Logger.0.MaxFileSize=5000 Logger.0.MaxFiles=10 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314;Set the timestamp to RTC ;Logger.1.Name=/tmp/CommLog ;Logger.1.Enable=1 I need to have milliseconds in the timestamp as well. What value should I use instead of 0x314? Is there any documentation regarding this file? Thank you
Last updated: 2024-03-16

Post by wollvieh on Raspi Pi Bullseye Webvisu Autostart CODESYS Forge talk (Post)
Anbei meine Lösung zum Autostart der Webvisu, vllt. hilft es jemandem... =============================== Raspberry Pi Bullseye 11 Autostart Codesys Webvisu im Kiosk Mode 1)Datei erstellen: sudo nano/etc/xdg/autostart/Visustart.desktop 2)Inhalt der Datei: [Desktop Entry] Type=Application Name=Visustart Exec=bash -c "sleep 30 && /home/pi/Desktop/Visu" 3)Visu Datei erstellen sudo nano /home/pi/Desktop/Visu 4) Inhalt der Datei: #!/bin/sh xset -dpms xset s off xset s noblank matchbox-window-manager -use_titlebar no & unclutter & chromium-browser -display=:0 --kiosk --incognito --window-positon=0,0 5) Datei ausführbar machen sudo chmod+x /home/pi/Desktop/Visu ... nach Neustart Raspi startet die Codesys Webvisu automatisch im Kiosk Mode ===============================
Last updated: 2024-03-24

Post by wollvieh on Raspi Pi Bullseye Webvisu Autostart CODESYS Forge talk (Post)
Anbei meine Lösung zum Autostart der Webvisu, vllt. hilft es jemandem... =============================== Raspberry Pi Bullseye 11 Autostart Codesys Webvisu im Kiosk Mode 1)Datei erstellen: sudo nano/etc/xdg/autostart/Visustart.desktop 2)Inhalt der Datei: [Desktop Entry] Type=Application Name=Visustart Exec=bash -c "sleep 30 && /home/pi/Desktop/Visu" 3)Visu Datei erstellen sudo nano /home/pi/Desktop/Visu 4) Inhalt der Datei: #!/bin/sh xset -dpms xset s off xset s noblank matchbox-window-manager -use_titlebar no & unclutter & chromium-browser -display=:0 --kiosk --incognito --window-positon=0,0 5) Datei ausführbar machen sudo chmod+x /home/pi/Desktop/Visu ... nach Neustart Raspi startet die Codesys Webvisu automatisch im Kiosk Mode ===============================
Last updated: 2024-03-24

Post by esave on OPC UA Server with on Codesys + OPC UA Client on Labview CODESYS Forge talk (Post)
Hello everyone I want a communication between my PLC as an OPC UA Server and Labview on my PC as the OPC UA Client. I have an Festo CPX-E-CEC-C1-PN PLC and I have the OPC UA Toolkit from Labview. I created some Variables for testing (see picture 1) on Codesys. I tried to use this Labview block diagram (see picture 2) but I cant connect the PLC to it. What do I have to type in the Server Endpoint URL and what in the Node ID? Is this a good way for communication with a PLC to a PC? If not is there another way?
Last updated: 2024-04-12

Post by jbcregen on Accessing parameters from a structure or function block with the web interface CODESYS Forge talk (Post)
I have a project with hundreds of OPC-UA variables available on the network. A lot of these variables are used actively in various scripts that run in background in the OS (Linux). I'm experimenting with Automation Server and I have a hard time understanding how the web interface populates its parameters list for a given PLC (<plc details="" parameters="" for="" plc="" 'xyz'="">).</plc> In this page, it looks like the only variables available are the ones that are of a "base" type : bool, TIME, String, INT, etc. All the variables that are nested into function blocks or structures are not available in the web interface, even if they are available to any OPC-UA client. Is this a limitation of the Automation Server or is there something that can be done in Codesys?
Last updated: 2025-12-01

Post by otbeka on CAA File Handling: "Read only" error CODESYS Forge talk (Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19

Post by alexgooi on Codesys KNX implementation CODESYS Forge talk (Post)
Dear forum, We are currently doing some research on the Codesys KNX implementation (https://store.codesys.com/en/codesys-knx-sl.html). We almost have it working but we are missing the last part. The setup: We have a Codesys virtual control container running on docker (4.17.0.0), the I/O is running over an Ethernet IP coupler (Weidmüller), and this is running fine. As far as I’m concerned this tells me that the ethernet device is working properly (the container has access to the outside world, including multicast). Underneath this ethernet adapter the KNX module is added (see picture). In the KNX device (Codesys) 2 input variables are added (see picture), and these are exported to ETS (ETS 5). In ETS A Codesys KNX device has been imported and the Codesys export was imported, afterwards the group addresses are attached to the variables (see picture). Afterwards this configuration is downloaded to the Codesys controller (Container) via ETS. ETS asks for the pressing of the programming button, when the virtual programming button is pressed the download starts and finishes without any errors. This tells me that ETS is communicating with the Codesys controller, and that the download process is ok (so far so good). Now the part where we are struggling with, somehow we need to convert the KNX TP to KNX IP. For this we have the following interface: Zenio KIPI SC (https://www.zennio.com/product/kipi-sc/) this is a KNX TP to IP interface. We have the following setup for this device (see picture) (an IP in the same subnet is used). We tried multiple combinations of IP addresses but the TP devices are simply not communicating to the Codesys container. Does anyone has any advice on what to try next. To make the question more explicit how can we link the TP bus to the Codesys device? Kind Regards Alex
Last updated: 2026-01-05

Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable CODESYS Forge talk (Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29

Post by ara32 on CODESYS 4 Linux: CODESYS Forge talk (Post)
Hello! I managed to correctly launch CODESYS Developer Studio 3.5.17, almost all functionality works. The only issue remaining is that when connecting to a device and obtaining its public key, the NCryptEncrypt function is called, which is not fully implemented in the DLL source code, resulting in the connection not being established. Currently, the code of this function in the Wine repository looks like this: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG || flags & NCRYPT_PAD_OAEP_FLAG) { FIXME("No padding and oaep padding not supported\n"); return NTE_NOT_SUPPORTED; } if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } The program crashes due to the NCRYPT_PAD_OAEP_FLAG flag. I'm not proficient in C++, but I attempted to add handling myself, and here's the result: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG) { FIXME("No padding not supported\n"); return NTE_NOT_SUPPORTED; } BCRYPT_OAEP_PADDING_INFO oaepInfo = { 0 }; oaepInfo.pszAlgId = BCRYPT_SHA1_ALGORITHM; NTSTATUS status = BCryptEncrypt(key_object->key.bcrypt_key, input, insize, &oaepInfo, NULL, 0, output, outsize, result, flags); if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } Now, when calling the connection, it crashes with the error "bcrypt:BCryptEncrypt flags 0x4 not implemented." Can anyone help with enhancing this functionality or at least point me in the right direction?
Last updated: 2024-03-22

Post by mariusz997 on Visualisation - internal error CODESYS Forge talk (Post)
Hi everyone. I try to reach Codesys but I have problem on the beginning. I use Codesys 3.5.18.60 and 3.5.18.30 . On both version I have this same problem - when I create new standard project with controller Control Win v3 x64, empty PLC program - I compile it and everything is ok. But when I add visualisation without any elements and compile it - I get: ~~~ ------ Build started: Application: Device.Application ------- Typify code... Generate code... Generate global initializations... [WARNING] SortingStation: HMI Device: PLC Logic: Application: Missing element configuration. Element may not be usable. [WARNING] SortingStation: fbOutletConveyour Device: PLC Logic: Application: C0196: Implicit conversion from unsigned Type 'WORD' to signed Type 'INT' : Possible change of sign [ERROR] Internal error:System.NullReferenceException: Odwołanie do obiektu nie zostało ustawione na wystąpienie obiektu (in english: Object reference not set to an instance of an object.). w _3S.CoDeSys.Codex86_64.V351500.CPUx86_64.CodeStore(TypeClass tc, Register RegBase, Register RegIndex, Int32 nOffset, Register RegSrc, Int32 nScale) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.GenerateVarAbsolut(IVariableExpression varexp, Int32 iArea, Int32 nAddress, IIndexInfo indexinfo, ICompiledType ctype, Int32 nTypeSize, IAccessMode am) w ..(_IVariableExpression ) w ..(IExprement ) w ..(IExprement ) w ..(_ICompoAccessExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IAssignmentExpression assign) w ..(_IAssignmentExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IExpressionStatement expstat) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, ISequenceStatement mainRoutine, Boolean bKeepCompileInformation, IEnumerable`1 subroutines) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, Boolean bKeepCompileInformation) w ..(_ICompiledPOU ) w _3S.CoDeSys.Compiler35180.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) w ..(_ICompiledPOU , Boolean , Boolean , _ICompileContext , _ICompileContext , Boolean , Codegeneration , Boolean& , Boolean , Boolean ) w ..(Boolean , Boolean , _ICompileContext , _ICompileContext , InitExitSignatureInfo , Boolean , Codegeneration , _ISignature , Boolean& , Boolean , Boolean ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature , InitExitSignatureInfo& , Boolean& ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(ICodegenerator ) w ..() w ..() Build complete -- 1 errors, 2 warnings : No download possible ~~~ Could someone help me with this problem? Thank you in advance Mariusz
Last updated: 2025-11-11

Post by ryusoup on JSONByteArrayWriter problem? CODESYS Forge talk (Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,
Last updated: 2023-10-04

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17

Post by solve-it on SysFileOpenAsync CODESYS Forge talk (Post)
Just realized that it is the /dev/input/js0 file. Don't think this is a prob either. Found the ConfigFile. Where and how to add /dev/input/js0? raspberry [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 [SysTarget] TargetVersionMask=0 TargetVersionCompatibilityMask=0xFFFF0000 [CmpLog] Logger.0.Name=/tmp/codesyscontrol.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=1000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC [CmpSettings] FileReference.0=SysFileMap.cfg, SysFileMap FileReference.1=/etc/CODESYSControl_User.cfg [SysExcept] Linux.DisableFpuOverflowException=1 Linux.DisableFpuUnderflowException=1 Linux.DisableFpuInvalidOperationException=1 [CmpWebServer] ConnectionType=0 [CmpOpenSSL] WebServer.Cert=server.cer WebServer.PrivateKey=server.key WebServer.CipherList=HIGH [SysMem] Linux.Memlock=0 [CmpCodeMeter] InitLicenseFile.0=3SLicense.wbb [SysEthernet] Linux.ProtocolFilter=3 [CmpSchedule] ProcessorLoad.Enable=1 ProcessorLoad.Maximum=95 ProcessorLoad.Interval=5000 DisableOmittedCycleWatchdog=1 [CmpUserMgr] AsymmetricAuthKey=6873d655ac1f166f3743feea42d2f3dd1b39ae40 [CmpSecureChannel] CertificateHash=09fd8d52be4ddd45a709bc9c95e2aa093b3f5695 [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpMask=1 ;raspberry [ComponentManager] ;Component.1=CmpGateway ;Component.2=CmpGwCommDrvTcp ;Component.3=CmpGwCommDrvShm [SysCom] ;Linux.Devicefile=/dev/ttyS [CmpBlkDrvCom] ;Com.0.Name=MyCom ;Com.0.Baudrate=115200 ;Com.0.Port=3 ;Com.0.EnableAutoAddressing=1 [SysProcess] Command.0=shutdown [CmpApp] Bootproject.RetainMismatch.Init=1 ;Application.1=Application ;Application.1=Application ;Application.1=Application Application.1=Application [CmpRasPi] Architecture=armv6l [CmpRedundancyConnectionIP] [CmpRedundancy] [CmpSrv] [IoDrvEtherCAT]
Last updated: 2024-07-16

Post by ruobian on Analog Input Delay Timer CODESYS Forge talk (Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20

Post by lbartik on J1939 TX/RX PDU1 CODESYS Forge talk (Post)
Is it possible to transmit a PDU1 PGN using the J1939 manager and local device? What if I need to transmit a PGN RQST via 0xEA00 (PGN 59904)? How would I do this P2P (Destination < 0xFF) or broadcast (Destination 0xFF)? I don't think this is possible for any destination type. I don't think it's possible to receive broadcast PDU1 messages either. For example, an address claim PGN 60928 (0x18EEFF80) is addressed to all nodes (0xFF) and not any specific local device so it will be filtered out. These are major oversights in the IoDrvJ1939 library to not support every PDU1 RX/TX scenario. IoDrvJ1939 supported scenario: 1. Receive (RX) PDU1 (P2P) destination-specific (PDU-specific < 255) to local device with matching address IoDrvJ1939 unsupported scenarios: 1. Receive (RX) PDU1 (P2P) global (PDU-specific = 255) 2. Transmit (TX) PDU1 (P2P) global (PDU-specific = 255) 3. Transmit (TX) PDU1 (P2P) destination-specific (PDU-specific < 255)
Last updated: 2024-09-23

Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20) CODESYS Forge talk (Post)
Hi, I would like to divide a project into multiple applications - as a minimum: one handling visualization and Alarm Manager, one handling I/O and plant control logic. But how to exchange variables between the applications? What have you done to get such a solution? In versions 3.5.19 and earlier, you can have Child applications, where the children can access a GVL in the Parent application. Children apps is no longer possible in 3.5.20 - but you can have 'sibling' apps - Several apps directly under PLC Logic, that is. But how do they best communicate? The Communication Manager / Data Sources Manager is sort of possible via OPC UA, but it seems like overkill and with some limitations - for example no ARRAY OF STRUCT possible this way. If you have separate devices in your project, you can exchange data via 'CODESYS ApplicationV3', but not other applications in the same device (see attachment Datasources.png). You can do it via 'Select the project type'->'Other Project' and select the same project file, but this leads to crashing the Development system when working with the variables afterwards. It would be great to hear your thoughts / experiences on this topic - Bjarne
Last updated: 2024-09-27

Post by breiter on Frustration-Fueled Feedback on Project File Management and Git Integration CODESYS Forge talk (Post)
Hi, supporting a text based storage format is on our roadmap, see https://www.codesys.com/the-system/releases-updates-lifecycle/release-plan-roadmap.html It will be an Add-On feature called "File Based Storage" for the professional developer edition. Structured text POUs will be stored as plain text. Other graphical languages will remain in an xml format. You will be able to switch the storage type for projects. Certain workflows will become easier this way. Nevertheless restrictions will remain because of CODESYS specific storage logic (for example how methods below function blocks are stored as file). So merging using our Git Integration Add-On remains the recommended workflow. A workflow involving Visual Studio Code as the main IDE is not supported. Simply because many topics like library management, task configuration or fieldbus configurators are not available for VS Code. A PLC project is a lot more than just some ST POUs. Best Regards
Last updated: 2024-10-16

Post by imdatatas on Auto Declare window disappears by itself in the Ladder editor CODESYS Forge talk (Post)
Hello Everyone, The "Auto Declare" window disappears by itself in the Ladder editor. For example, a new function block is wanted to be added to the Ladder editor. (For example; MC_Jog block and instance name will be fbMcJog). To do this, "Empty box with EN/ENO" is added to the ladder line from the Toolbox on the right and when you type MC_Jog in the empty box and press enter, normally the "Auto Declare" window appears and you are expected to be asked to write the instance name here. However, this "Auto Declare" window closes itself immediately, it does not wait for the user to enter a value or close the window. I often encounter this situation in many IDE versions. Does this seem like a bug? If anyone has encountered a similar problem while creating a new program name, function or function block instance name regarding the "Auto Declare" window and knows a solution, I would be glad if you could share it. Best wishes Imdat
Last updated: 2025-03-06

Post by mondinmr on Unexpected behavior in cyclic encoder read method during INT overflow (wrap-around) CODESYS Forge talk (Post)
Hi everyone, I’m investigating a potential issue with a cyclic method we use for reading incremental encoders in our libraries. I’ve come across two implementations that, at first glance, appear to perform the same operation: motionUnit.vlPositionActualValue is UINT due strange encoder type. Version A METHOD PROTECTED cyclicReadField VAR_INST actPosFieldOld: INT; rI: INT; delta: INT; END_VAR rI := TO_INT(motionUnit.vlPositionActualValue); delta := rI - actPosFieldOld; m_actPosRaw := m_actPosRaw + TO_LREAL(delta); actPosFieldOld := rI; IF settings.velocityFeebackMapped THEN m_actVelRaw := TO_LREAL(motionUnit.velocityActualValue); END_IF Version B METHOD PROTECTED cyclicReadField VAR_INST actPosFieldOld: INT; END_VAR m_actPosRaw := m_actPosRaw + TO_LREAL(TO_INT(motionUnit.vlPositionActualValue) - actPosFieldOld); actPosFieldOld := TO_INT(motionUnit.vlPositionActualValue); IF settings.velocityFeebackMapped THEN m_actVelRaw := TO_LREAL(motionUnit.velocityActualValue); END_IF Both use INT and the same delta logic, so they seem equivalent. However, when an overflow (wrap-around) occurs, version A continues correctly as expected, while version B unexpectedly resets to -32768 without a clear reason. Has anyone experienced similar behavior or can shed light on what might be happening here? It almost seems as if the cast to LREAL is being applied before the calculation — but that would be illogical and potentially very dangerous in many situations! Thanks!
Last updated: 2025-05-13

Post by bmatlove on Variable Length Array - Cannot mix variable and fixed length dimensions? CODESYS Forge talk (Post)
Using Codesys 3.5.18.30 I am trying to work with an array of variable length in one dimension, but known in the other dimension. For example, using an array that represents a list of items, each with an attribute profile. I do not know how many items will be in the list, but I know that every item has 5 attributes, like size, weight, etc. Codesys does not seem to be able to accept this. I have referenced Data Type: ARRAY OF documentation page, which is not explicit if variable & fixed length array dimensions can be mixed. In the VAR_IN_OUT scope, I initially tried MY_ARRAY : ARRAY [*, *] OF REAL; which was no problem, of course. I then modified it to MY_ARRAY : ARRAY [*, 1..5] OF REAL; which throws C0006: ', or ]' expected instead of '..' among consequent downstream errors. I then used the Auto Declare -> Array Wizard, which accepted (asterisk)-(asterisk) and 1-5 for 2-dimensional lower and upper bounds. It output: MY_ARRAY: ARRAY[*..*, 1..6] OF INT; which throws the same error stream. What's the deal here? Is this possible?
Last updated: 2025-05-23

Post by josul on Web Client HTTPS Communication Issue CODESYS Forge talk (Post)
Web Client Library Documentation Company: 3S - Smart Software Solutions GmbH Title: Web Client Version: 1.0.1.7 Categories: Application|Utils Namespace: WEB_CLIENT Author: 3S - Smart Software Solutions GmbH Placeholder: WebClient I encountered an issue using this library above. Note it is now part of Codesys IIoT Libraries SL in the form of Web Client SL, but I am not using this version. I was sending Content-Type: application/json, HTTP POST using a HTTPS URL. No issue observed initially, successful operation. At some point operation stopped and the codesyscontrol.log file started to accumulate errors: ERROR: TlsCreateContext2: Failed to save context. An application reset failed to resume operation and I was unable observe any TCP connection forming to a destination port 443. The error appeared as a TCP_INIT error. I can find no details as to what may have happened or why a reset of the PLC application did not resume operation. Testing with a curl operation proved to be successful, so I am confident there was no fundamental networking issue preventing a TCP connection forming. The solution was to reboot the hardware itself, but this is not satisfactory in the long term. Is there any description of the TLS error I received? Is there any suggestion here that there might be an issue with certificates? Any advice or information is appreciated.
Last updated: 2025-06-05

Post by ranadheer on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Hello Jaco Pretorius, I came across your post regarding CodeSys control for PLCnext. I’m currently working on a similar setup and had a quick question. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by ranadheer on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Hello Jaco Pretorius, I came across your post regarding CodeSys control for PLCnext. I’m currently working on a similar setup and had a quick question. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC CODESYS Forge talk (Post)
Hello Everyone, I'm working on a CODESYS Standard Project using CODESYS Control Win V3 x64 with Structured Text. The goal is to integrate a Phoenix Contact device coupler (Part ID: BK PN TPS 2403869) via PROFINET. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by user0815 on Kommunikation zwischen ROS2 und CODESYS über Web Sockets CODESYS Forge talk (Post)
Hallo zusammen, ich hoffe ihr könnt mir weiterhelfen. Meine CODESYS Version ist die V3.5 SP19 Patch 4 und die Zielsystemversion ist die 4.10.0.0 . Ich verwende CODESYS ohne Lizenz. Ich probiere eine Verbindung über Web Sockets zwischen ROS und CODESYS aufzubauen. Der Client von CODESYS verbindet sich mit dem Ros Bridge Server aber ich weiß nicht wie ich dem Ros Server sage welches Topic er publishen soll. Über Node-Red habe ich eine Verbindung aufbauen können. Dafür habe ich "node-red-contrib-flowake-ros-nodes" verwendet. Den Daten Austausch habe ich mit mit Wireshark angeschaut und nun probiere ich den mithilfe von CODESYS nachzubauen. NAch dem sich der Client verbunden hat muss folgende Nachricht übermittelt werden:"{"op":"call_service","id":"call_service:/rosapi/topic_type:1","type":"rosapi/TopicType","args":{"topic":"/cmd_vel"}}." Ich vermute es funktioniert über Frames aber ich weiß nicht wie ich es umsetzten soll. Besten Dank für die Hilfe und schöne Grüße
Last updated: 2024-01-03