Post by arrotek on Codesys HMI Redundancy
CODESYS Forge
talk
(Post)
Is there a way to run Codesys HMI on two different PC's and have the web visu clients fail over to the HMI instance that is wokring or running?
Last updated: 2024-05-30
Post by nano on Is it possible to profile builds?
CODESYS Forge
talk
(Post)
pls check whats gookg on with antimalware-service-executable during the build most of my problem are directly connected to that "great" microsoft feature
Last updated: 2024-06-06
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
https://us.store.codesys.com/codesys-control-for-raspberry-pi-sl.html Quoted from the "additional requirements" section : The operating system Raspberry Pi OS (32-bit)
Last updated: 2024-06-14
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
This is what I see in codesys window. And here is with the netstat command on the pi
Last updated: 2024-06-23
Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5
CODESYS Forge
talk
(Post)
you need to have an own task for the one wire and io update these slaves in an own low prio task!
Last updated: 2025-10-18
Post by nano on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
CODESYS Forge
talk
(Post)
have u turned on the Ip-Setter in codesyscontrol.cfg? [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1
Last updated: 2025-11-11
Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
Hi All, We downgraded Codesys LAD/FB in the IDE to version 4.5 and it works. Codesys Version 4.6 lad/fb not working. Was the way we fixed this. Kind Regards Shaun
Last updated: 2025-11-17
Post by mbart on VAR_INFO from inside of a FB to get info on the instance.
CODESYS Forge
talk
(Post)
I experienced the same problem: using __VARINFO is working only in PRG context, while it crashes if used inside Function Blocks. I would really appreciate if they would fix this issue
Last updated: 2025-12-04
Post by gseidel on MC_Phasing state explenation
CODESYS Forge
talk
(Post)
Hi kenth1973, no, we do not have this kind of information on internal variables. iPhasingState has been removed and is no longer present in current versions of SoftMotion. Best regards, Georg
Last updated: 2025-12-17
Post by reinier-geers on SYSDIR 3.5.17.0
CODESYS Forge
talk
(Post)
I had a funcioning Directory read wit SYSDIR. Now ive got a new controller with Linux. and now i get only ordners Names. NO file Names !! WHY ? It workt already on a other with linux. But that was i think version 14
Last updated: 2026-01-06
Post by reinier-geers on SYSDIR 3.5.17.0
CODESYS Forge
talk
(Post)
I had a funcioning Directory read wit SYSDIR. Now ive got a new controller with Linux. and now i get only ordners Names. NO file Names !! WHY ? It workt already on a other with linux. But that was i think version 14
Last updated: 2026-01-06
Post by blitz on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
So in my case the solution was that I had both smooth path and round path in the code. Both blocks had their own buffer and seemed completely separate but still triggering Execute on both caused the mentioned problems. When I blocked Execute the problems disappeared.
Last updated: 2026-01-11
Post by gilad on CODESYS SoftMotion Generic DSP402 on WAGO PFC200 + Festo CMMT-AS: MC_Power stays Busy, Controlword remains 0
CODESYS Forge
talk
(Post)
Thank you very much, What FESTO provides should work even if I use another PLC (WAGO) that is not from FESTO?
Last updated: 2026-06-30
Post by eschwellinger on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
this is probably: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_linux_dedicated_user.html ..switch back from rootless mode due GPIO will not work.
Last updated: 2026-07-19
Post by charly29160 on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
wird nicht mit kopiert - sorry: PermittedPath.0=/dev/i2c PermittedPath.1=/dev/spidev PermittedPath.2=/sys/class/gpio/ PermittedPath.3=/dev/gpiochip
Last updated: 2026-07-20
Post by charly29160 on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
Problem gefunden und erledigt => in CODESYSControl_User.cfg ergänzt: [CmpCharDevice] PermittedPath.0=/dev/i2c PermittedPath.1=/dev/spidev PermittedPath.2=/sys/class/gpio/ PermittedPath.3=/dev/gpiochip Dann funktioniert es wieder Gruß Karl Schuler
Last updated: 2026-07-20
Post by charly29160 on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
Noch eine Info dazu: als Version der Pi MC SL wird mir 4.21.0.0 angezeigt. In der log steht jedoch für IoDrvGPIO: 4.17.0.0 was ist das Problem?
Last updated: 2026-07-20
Post by timvh on CAA.File.Write – Unexpected characters when writing a CSV file
CODESYS Forge
talk
(Post)
For sure you must use LEN(). SIZEOF() means you write a number of bytes based on the size of the variable type. For your STRING this will be 80 characters, but this will write unexpected characters in your file.
Last updated: 2026-09-09
Post by davidbo on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Under Application->"Task Configuration" you can find your task double click on that and you will see a fane to the right. You find the watchdog enable switch it off or increase the time
Last updated: 2025-11-17
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
I did some work around by adding IN switch on top of OUT bulb picture(SwitchImage) and setting IN switch button to invisible but this is not quite elegant. How to combine it to one visu element?
Last updated: 2025-11-20
Post by danamocca on SM3_CNC Sentence modifier
CODESYS Forge
talk
(Post)
Hi! Does anyone have an example of ReadNCFile2 with Sentence Modifier? Current examples on CODESYS help page are outdated and have a lot of errors, like "SMC_CNC_LibParams.MAX_SUBPROGRAM_NESTING_DEPTH" calls, which are not present in current version of SMC3_CNC library.
Last updated: 2025-12-25
Post by karsonsv on CODESYS HMI and 2 monitors
CODESYS Forge
talk
(Post)
I need open visualization on two monitors (every monitor 19201080). In TargetVisu i configure Scaling Options as Fixed 38401080. But visualization open onli main monitor and onli half.
Last updated: 2026-01-02