Search talk: OPC UA Server

 
<< < 1 .. 13 14 15 16 17 .. 28 > >> (Page 15 of 28)

Simulation mode and OPC CODESYS Forge talk (Thread)
Simulation mode and OPC
Last updated: 2011-02-14

question opc CODESYS Forge talk (Thread)
question opc
Last updated: 2017-12-18

OPC/ DDE and Excel CODESYS Forge talk (Thread)
OPC/ DDE and Excel
Last updated: 2017-12-08

RASPBERRY OPC CONFIGURATION CODESYS Forge talk (Thread)
RASPBERRY OPC CONFIGURATION
Last updated: 2019-07-03

OPC and windows versions CODESYS Forge talk (Thread)
OPC and windows versions
Last updated: 2017-02-20

OPC download error CODESYS Forge talk (Thread)
OPC download error
Last updated: 2009-01-19

OPC Absturz in Windows CODESYS Forge talk (Thread)
OPC Absturz in Windows
Last updated: 2012-03-14

Codesys OPC simulator CODESYS Forge talk (Thread)
Codesys OPC simulator
Last updated: 2017-05-25

OPC client with CODESYS CODESYS Forge talk (Thread)
OPC client with CODESYS
Last updated: 2014-10-17

OPC via Lan problem CODESYS Forge talk (Thread)
OPC via Lan problem
Last updated: 2009-10-14

Post by alexgooi on OPC-UA and other communication questions CODESYS Forge talk (Post)
Dear forum, I currently have a big question mark above my head, and maybe this forum can shine some light on the situation. I recently updated to Codesys 3.15 SP19 Patch 6. And now I’m trying to setup the OPC-UA server, besides that I’m trying to connect to the controller with the Codesys V3 (Ethernet) protocol. OPC-UA I have installed the correct licenses on my controller (Runtime and communication). I’m able to connect to the controller with an OPC-UA client, and I’m able to browse the tags, so far so good. Therefore I’m assuming that the OPC-UA server is running on the controller. But now the strange part, in the device security settings I have set the communication Policy to BASCI256SHA256 ( I also have tried the other ones) and the communication mode is set to secure if possible (I also have tried all the other ones) (see picture). With these settings I would assume that I would only be able to login with a Basic256SHA256 policy with a client. But the opposite is true, I am able to login using the no policy mode and when I set it to Basic256SHA256 the client (UA-Expert) notes that this policy is not available on the server. I then check the certificates and I noted that there is no certificate for the OPC-UA server, I tried to generate one but it gave the error that the certificate has not been created by the device (See picture). To summarize I have no clue what is going on, and the controller does the opposite of what I would expect. Codesys Ethernet V3 driver I have a HMI connected to the same controller using the Ethernet V3 driver. But this will not connect. I tried all the Protocols (see picture), with and without the username and password enabled. But it will not connect, when I scan the available servers I can see the controller with the port number that I am expecting, so I’m assuming that the Codesys V3 ethernet driver is up on the controller. Does anyone can give me some direction, because the stuff that I tried doesn’t make sense to me. Thank you in advance
Last updated: 2024-04-02

Post by davidbo on Is OPC communication possible with server certificate but no client certificate CODESYS Forge talk (Post)
I was just wondering is the following option possible and what the settings should be. Is OPC communication possible with only and mandatory server certificate but no client certificate?
Last updated: 2023-10-06

Post by vformanek on Datasource OPC UA Client error ID:7012 CODESYS Forge talk (Post)
Sorry to bother but what do you mean by target ?
Last updated: 2023-11-21

Post by vincentd on Datasource OPC UA Client error ID:7012 CODESYS Forge talk (Post)
the target is the codesys software executing the PLC code like ladder / instruction list etc...
Last updated: 2024-04-05

Post by rajshaswat on OPC-UA and other communication questions CODESYS Forge talk (Post)
check this if it helps : https://youtu.be/Hdpbsp2jG3Q?si=NTwK13c_YOSZXM3v
Last updated: 2024-04-06

Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager CODESYS Forge talk (Post)
After 3 hours is some progress - please find in attachment - progress1.jpg
Last updated: 2024-09-04

Post by thn-power on OPC UA Companion Specifications / Information model CODESYS Forge talk (Post)
Hi Anyone have a solution for this? What is the reason?
Last updated: 2024-09-18

Sysfile copy to server CODESYS Forge talk (Thread)
Sysfile copy to server
Last updated: 2012-01-13

ENI Server Ãœbersetzungsdateien CODESYS Forge talk (Thread)
ENI Server Ãœbersetzungsdateien
Last updated: 2009-10-05

tcp server CODESYS Forge talk (Thread)
tcp server
Last updated: 2017-05-28

DDE server CODESYS Forge talk (Thread)
DDE server
Last updated: 2007-10-17

TCP Server connection CODESYS Forge talk (Thread)
TCP Server connection
Last updated: 2019-11-30

ENI Server - Ãœbersetungsdateien CODESYS Forge talk (Thread)
ENI Server - Ãœbersetungsdateien
Last updated: 2010-04-20

FTP server? CODESYS Forge talk (Thread)
FTP server?
Last updated: 2014-09-03

XEON Server CODESYS Forge talk (Thread)
XEON Server
Last updated: 2018-10-17

<< < 1 .. 13 14 15 16 17 .. 28 > >> (Page 15 of 28)

Showing results of 698

Sort by relevance or date