Post by rafaelbrito on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. CODESYS Forge talk (Post)
When trying to use the Visualization ToolBox, no objects appear and the following error appears. Could you tell me what this error could be? The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array. Can anyone tell me what this error is?
Last updated: 2024-12-03

Post by simotion on Pointer to Softmotion axis CODESYS Forge talk (Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25

Post by squale on URL jumps between different visualizations behind a reverse proxy CODESYS Forge talk (Post)
Hi kevinrn, I have the same question as yours. On my side I try to make nginx work but it doesn't goes well. I think the sub_filter doesn't work int this case.
Last updated: 2024-07-26

Post by macros8 on Alarm Management - latched variable represented as Text list CODESYS Forge talk (Post)
Hi, I havenΒ΄t noticed you put the comment here. I thing itΒ΄s a bit different. What I want is to have detail errors of technology in data type e.g. INT. This variable I would latch to the corresponding error msg but I would like to get it convert to text from the text list and not keep it in INT form. Example. Main error Valve Error: SubErrors 1 - Both sensors 2 - Not retracted in time 3 - Not pulled out in time In HMI Main error + latch SubErrors => "Valve Error: Both sensors" The benefit is that text lists are part of translation and can be easily manipulated. I know I can create whole string msg in PLC but then, it lose advantage of Alarm management. Thanks. M.
Last updated: 2023-11-07

Post by garmusd on Raspberry Pi 5 GPIO not working. CODESYS Forge talk (Post)
Hi, Codesyscontrol 4.13.0.0 Raspberry Pi5 64bit with latest updates. Cant get working GPIO - no output and no input. SPI/I2C not tested. GPIOs B+/Pi2, Input/Output is set in the parameters, assigned variables int the Mapping. Absolutely no reaction. Do I need to configure anything else to make it work? Thanks!
Last updated: 2024-09-26

Post by timvh on Converting each character to a string into ASCII CODESYS Forge talk (Post)
Nice puzzle for a Saturday afternoon :-). Here my suggestion: VAR sInput : STRING := 'R123'; byChar : BYTE; sOutput : STRING; i: INT; END_VAR sOutput := ''; IF LEN(sInput) = 0 THEN RETURN; END_IF FOR i := 0 TO LEN(sInput) - 1 DO byChar := sInput[i]; sOutput := Concat(sOutput, TO_STRING(byChar)); END_FOR
Last updated: 2024-11-09

Post by benemenn on Type mappings in Datasource CODESYS Forge talk (Post)
Hi! I am trying to achieve the same issue. Has there been a solution? I can create the mapping, and map the local variable, but somehow the object does not update. Furthermore, i have an issue where codesys doesn't let me set ReadWrite accesses to the variables in the "Type Mapping" place. The access will simply not be set. Has anyone ran int that issue?
Last updated: 2025-04-02

Post by mondinmr on Jitter problems on imx8 CODESYS Forge talk (Post)
SOLVED!!! In this imx8 max_cstate=1 in kernel boot parameters is not working! We found a workaround: #include <stdio.h> #include <fcntl.h> #include <unistd.h> #include <stdint.h> int main(void) { int fd; uint32_t value = 0; fd = open("/dev/cpu_dma_latency", O_WRONLY); if (fd < 0) { perror("Error opening /dev/cpu_dma_latency"); return 1; } if (write(fd, &value, sizeof(value)) != sizeof(value)) { perror("Error writing to /dev/cpu_dma_latency"); close(fd); return 1; } while (1) { pause(); } } This simple code launched before CODESYS do the same work! Now jitter is identical as measured by cyclictest!
Last updated: 2023-10-19

Post by rmaas on STRING conversions to DWORD CODESYS Forge talk (Post)
Hi, The '' characters in Codesys are there only to indicate it is a STRING type. They are not actually added to the string, maybe you are adding them unintentionally in the concat function? You can send your data from Codesys to Hercules to verify... Another option is to send the data as an array of bytes instead of a string, with every byte representing 1 ASCII character. https://www.ascii-code.com/ This way you are 100% sure Codesys is not adding any unwanted characters.
Last updated: 2025-01-31

Unable to connect to this device CODESYS Forge talk (Thread)
Unable to connect to this device
Last updated: 2024-06-28

Cursor to move to a control CODESYS Forge talk (Thread)
Cursor to move to a control
Last updated: 2025-08-12

VAR_IN_OUT, POINTER TO and REFERENCE TO CODESYS Forge talk (Thread)
VAR_IN_OUT, POINTER TO and REFERENCE TO
Last updated: 2021-11-16

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23

Post by hclai on Maximum Array Index Issue CODESYS Forge talk (Post)
I was trying to use a table object in visualization. I want to dynamically show the valid rows in the table. However, it does not work when there is 1 row. i put the maximum array index to 1. it does not show the 1st row. when i change to 2, it show the second row only. my project with older visualization profile version is working perfectly fine. I did some test and realized that i must use a Row Selection variable to change from 0 to 1. With this change of Row selection, then the row 1 will show up.
Last updated: 2025-06-19

Post by timvh on Array to String CODESYS Forge talk (Post)
The new (UTF8) string library is faster and can handle large strings. https://content.helpme-codesys.com/en/CODESYS%20String%20Libraries/_strlib_start_page.html PS, in CODESYS, the maximum string length is not 255 characters. The String functions of the standard library are limited to strings of 255 characters. But you can use other (memory) functions to handle strings larger than 255 characters.
Last updated: 2024-07-22

Post by k2saki on How to define CONDITIONAL PRAGMA that effects all ST-POU in project. CODESYS Forge talk (Post)
I'd like to use same code/project in different devices. (RPi, PLC) I change some lines in some POU before compiling. (array size, file path, etc ) My question is How to define pragma that effects all ST-POU in project. Is it possible ? I've read this. https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_pragma_conditional/
Last updated: 2024-05-12

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Hello! I have tried read a file to the string variable. But I faced a problem - there is about 2800 bytes of information in file, but string have a limit 2393 bytes. I made two variables with same address (for automatic convertion) - string[3000] and array of bytes[1..3000]. And I noticed that array of bytes contains all information from file, but string shows only first 2393 bytes. So I have lost information. Is there really such a limitation? Or I have an error in my program and Codesys 2.3 have no limit for such kind of conversation between string and array of bytes? Thank you very much!
Last updated: 2025-04-01

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Thank you for your answer! I know that 0 will be the end of the string. I checked it. There is no 0 in array of bytes. I made screenshots. There is array of bytes, aborted string and the result of my test via online converter.
Last updated: 2025-04-02

Post by gilbertamine on Comparing Arrays of structure CODESYS Forge talk (Post)
Hi Everybody, I'm looking for a simple way of comparing two array of a structure. My structure is define like this : TYPE Positions_T : STRUCT PosX: DINT; PosY: DINT; PosZ: DINT; END_STRUCT END_TYPE I have multiples Var : ARRAY [0..220] OF Positions_T, that I need to compare quickly. I don't really want to do a Loop that goes by every 220 points and compare each one of them so I was wondering if there is another way. I came accross the MEM.Compare function, but it require to know the size in Bytes of the memory, and I don't know how to do that... Has anybody an idea on how to do the comparing easily ? Thanks in advance
Last updated: 2024-08-22

Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string CODESYS Forge talk (Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses β€œ$DB,” which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29

Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string CODESYS Forge talk (Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses β€œ$DB,” which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Browser's bug... Sorry
Last updated: 2025-04-02

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
Last updated: 2024-05-04

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
works
Last updated: 2024-05-06

Post by mariapaola on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3 CODESYS Forge talk (Post)
Hi, Would really appreciate your insights in this issue I have. I am currently using a WAGO 750-881 with multiple IO devices. For one of them I already occupied the MODBUS Master configuration tool so I cannot overwrite it for my other devices. I have a total of two serial interfaces WAGO 750-652. The first one is instantiated in COM2 and doesn't need any protocol since the information comes in an specific formatting that need little code to differentiate between needed info. This one is working just fine. The second one is where I have an issue. I have tried to instantiate the port using MODBUS library modb_L05.lib to properly receive the data from an ARDUINO and I am absolutely unable to open the port: Signal DEVICE2.fbModbus.MODBUS_EXT_MASTER.Interface.Com_Port_Ist_Offen is never TRUE, among with all other signals from that interface, while signal DEVICE1.COM2.Com_Port_Ist_Offen is TRUE, and the other signals also read as TRUE or FALSE. I have tried instantiating the second one as the first one, changing COM3 to COM4, I've tried a lot of things but it wont ever open the channel. I don't know if you have any recommendations for me. For both physical modules, both witness LEDs A and E are on. First one is instantiated like this: PROGRAM DEVICE1 VAR wBaudRate : WORD := BAUD_9600; bDataBits : BYTE := 8; bParity : BYTE := 0; bFlowControl : BYTE := 3; (RS422 FullDuplex with continous send) i : INT; COM2 : SERIAL_INTERFACE; xOpenPort2 : BOOL := TRUE; ( Flag to open the Port ) xInitPort2 : BOOL; ( Flag to initiallize the Port ) ReceiveBuffer2 : typRing_Buffer; END_VAR COM2( bCOM_PORT_NR := 2, cbBAUDRATE := wBaudRate, cbsBYTESIZE := bDataBits, cpPARITY := bParity, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := bFlowControl, utRECEIVE_BUFFER := ReceiveBuffer2, ptSEND_BUFFER := ADR(SendString2), xINIT := xInitPort2, xOPEN_COM_PORT := xOpenPort2, iBYTES_TO_SEND := LEN(SendString2)+1, xSTART_SEND := xSendActive2 ); Second one like this: PROGRAM DEVICE2 VAR COM4 : SERIAL_INTERFACE; xInitPort4 : BOOL := TRUE; xOpenPort4 : BOOL := TRUE; ReceiveBuffer4 : typRing_Buffer; fbModbus : MODBUS_EXTENDED_MASTER_RTU; fbError : enumMB_ERROR; stQuery : typModbusExtendedQuery; stResponse : typModbusResponse; au16Data : ARRAY[0..14] OF WORD; i : INT; tPoll : TON; END_VAR COM4( bCOM_PORT_NR := 4, cbBAUDRATE := BAUD_9600, cbsBYTESIZE := 8, cpPARITY := 0, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := 2, ( RS-485 half-duplex ) utRECEIVE_BUFFER := ReceiveBuffer4, xINIT := xInitPort4, xOPEN_COM_PORT := xOpenPort4, xSTART_SEND := xSendActive4, ); stQuery.SlaveAddress := 1; stQuery.FunctionCode := 3; stQuery.Read_StartAddress := 0; stQuery.Read_Quantity := 15; (Poll code) fbModbus( ENABLE := TRUE, bCOM_PORT := 4, ( COM4=> 750-652 port ) cbCOM_BAUDRATE := BAUD_9600, cpCOM_PARITY := 0, csCOM_STOPBITS := 1, cbsCOM_BYTESIZE := 8, cfCOM_FLOW_CONTROL := 2, TimeOut := T#500ms, StartFunction := xStart, ExtQuery := stQuery, Response := stResponse, MB_Error => fbError ); FOR i := 0 TO 14 DO au16Data[i] := stResponse.Data[i]; END_FOR;
Last updated: 2025-11-28