Post by timvh on How to manage soft container licenses for (remote) multi units? CODESYS Forge talk (Post)
You need to activate an individual license (ticket number) for each device. THe hardware of each device is unique, so you cannot copy a soft container from one device to another. This license can be installed in a local (wibu - codemeter) soft container, or you could optionally activate it on a hardware (USB) key. The benefit of the key is that you can easily move it to another device, nor does it get lost when you replace parts of the hardware of the device or completely overwrite the image. See: https://store.codesys.com/en/codesys-key.html
Last updated: 2025-04-08

Post by andrej on Creating, using an external Function. CODESYS Forge talk (Post)
Hello all, I would like to create a simple which runs directly on Control WinV3 x64 3.5.21.0 For this purpose I created a simple dll myAdder.dll in Cpp // MyAdder.cpp // cl /LD /EHsc MyAdder.cpp /Fe:MyAdder.dll #include <windows.h> extern "C" __declspec(dllexport) int __cdecl CmpMyAdder_Add(int a, int b) { return a + b; } I added the dll in the respective folder. Furthermore I "registred" the dll in the CODESYSControl.cfg. However, when I want to use the library I get the error message: Uresolved reference: *'CMPMYADDERADD' * Can you give me a hint what step I missed or where I need to declare the dll, such that the dll resp. the reference can be resolved. Many thanks and kind regards
Last updated: 2025-04-18

Post by abuckie on Getting raw value as full resolution for ADS1115 CODESYS Forge talk (Post)
I just found this and I am getting a value larger than 16 bit, around 81000 something. I am reading a 5 volt value and I am using level shifters for the i2c bus. This is how I have the channel configured: ADS1115.usiAddress := 16#48; ADS1115.ChannelConfigs[0].Active := TRUE; ADS1115.ChannelConfigs[0].PGA := FSR_6144mV; ADS1115.ChannelConfigs[0].InputMux := Single_0; RawAnalogValue := ADS1115.Channels[0].Value; It looks like every value is a multiple of 3. Any idea where to look to fix this? I think i found what I want to change in UpdateChannels Channels[FChannelNo].Value := INT_TO_REAL(WORD_TO_INT(LValue) * GetFullScaleRange(ChannelConfigs[FChannelNo].PGA)) / 2048.0; I try to edit it but I can't, sorry if this is a basic question, I am new to CODESYS.
Last updated: 2025-05-22

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Hi, I want to use two OneWireMaster on a Raspberry Pi5. I'm running Codesys Control for Raspberry Pi 64SL V 4.15.0.0. Under Linux I've configured two GPIOs for 1w bus usage on GPIO4 and GPIO27. Under Linux both masters seem to work fine and I can readout both sensors connected to both GPIOs. The two masters are 'w1_bus_master1' and 'w1_bus_master2'. In Codesys I've configured to OneWireMasters with the corresponding file paths. But in Codesys the 2nd onewiremaster "w1_bus_master2" doesn't work. Status is showing "OnewireMaster : Not running" What am I doing wrong? Does Codesys on Raspberry support multiple OneWireMasters? Any help is appreciated.
Last updated: 2025-06-10

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Hi, I want to use two OneWireMaster on a Raspberry Pi5. I'm running Codesys Control for Raspberry Pi 64SL V 4.15.0.0. Under Linux I've configured two GPIOs for 1w bus usage on GPIO4 and GPIO27. Under Linux both masters seem to work fine and I can readout both sensors connected to both GPIOs. The two masters are 'w1_bus_master1' and 'w1_bus_master2'. In Codesys I've configured to OneWireMasters with the corresponding file paths. But in Codesys the 2nd onewiremaster "w1_bus_master2" doesn't work. Status is showing "OnewireMaster : Not running" What am I doing wrong? Does Codesys on Raspberry support multiple OneWireMasters? Any help is appreciated.
Last updated: 2025-06-10

Post by pauloricardoss on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option CODESYS Forge talk (Post)
I am having the same problem. 'Update Raspberry PI' disappeared from the 'Tools' menu. Using RaspberryPI 3B+, Codesys V3.5 Sp21 + RaspberryPI Package 4.16. I installed the package as Administrator, executed Codesys as Administrator I also tried to connect using the deploy (even with ssh and everything enabled on the RaspberryPi I received password denied). I used in the past the same equipment with Codesys V3.5 Sp18 and RaspberryPI Package 4.08, it was really easy. (I also did a brand new RaspbianOs installation to make sure that nothing affect the connection). Anyone, knows how to fix it? Thanks,
Last updated: 2025-06-13

Post by buczekj on About CPU Loading CODESYS Forge talk (Post)
This is a phenomenon that I have seen myself and with others. Texas instruments wrote an application note with this same issue. They noted with Codesys 3.5.19.10, that selecting CPU 1 as the EtherCAT task showed CPU spiking improvements over the performance of cores 0, 2, and 3. It appears to be linked to EtherCAT, are you configuring for use with distributed clocks? If so, I recommend choosing the 'Based on Input Reference' option. I have found it to reduce the CPU usage spike maximum slightly (see attached). See link to TI (also attached in case link breaks) https://www.ti.com/lit/an/spradh0/spradh0.pdf?ts=1723546111357
Last updated: 2025-07-01

Post by andrej on Signing of Boot Application for Raspberry Pi CODESYS Forge talk (Post)
Hello all, I would like to sign my boot application for my Raspberry PI. I generated the X509 Certificate and loaded it to the raspberry. It is successfully displayed as trusted certificate. However, I cannot download and start the Application to the Rasperry, due to a signature mismatch.The error message is rather clear, but I still don’t see how I can fix the issue, since the certificates on the Controller seem to mach the certificate in the user profile. Could you tell me where the error is or which step I am missing. Many thanks and kind regards Andreas
Last updated: 2025-07-17

Post by andrej on Signing of Boot Application for Raspberry Pi CODESYS Forge talk (Post)
Hello all, I would like to sign my boot application for my Raspberry PI. I generated the X509 Certificate and loaded it to the raspberry. It is successfully displayed as trusted certificate. However, I cannot download and start the Application to the Rasperry, due to a signature mismatch.The error message is rather clear, but I still don’t see how I can fix the issue, since the certificates on the Controller seem to mach the certificate in the user profile. Could you tell me where the error is or which step I am missing. Many thanks and kind regards Andreas
Last updated: 2025-07-17

Post by andrej on Signing of Boot Application for Raspberry Pi CODESYS Forge talk (Post)
Hello all, I would like to sign my boot application for my Raspberry PI. I generated the X509 Certificate and loaded it to the raspberry. It is successfully displayed as trusted certificate. However, I cannot download and start the Application to the Rasperry, due to a signature mismatch.The error message is rather clear, but I still don’t see how I can fix the issue, since the certificates on the Controller seem to mach the certificate in the user profile. Could you tell me where the error is or which step I am missing. Many thanks and kind regards Andreas
Last updated: 2025-07-17

Post by timvh on Dynamically enabling/disabling Modbus slave devices in runtime (performance issue with timeouts) CODESYS Forge talk (Post)
As far as I remember, the Reconfigure functionality doesn't work for Modbus devices. But... Each Modbus device in your device tree has a name. You can set the property "Enable" of this device to FALSE to stop communicating with it. So if one of your Modbus Slave devices name is "MbSlave1" in the device tree, then in your code you can set the Enable to FALSE to let it stop communicating: MbSlave1.Enable := FALSE; Please let us know if this worked on your controller with your application and your CODESYS version. Alternatively you could use the ModbusFB library. See: https://forge.codesys.com/prj/codesys-example/modbus/home/Home/
Last updated: 2025-08-13

Post by alexgooi on Codesys virtual control redundancy CODESYS Forge talk (Post)
Dear Forum, I’m currently investigating the possibilities of Codesys virtual control (Linux). The research rig consists of a PC (Debian with real time kernel) with a docker server installed on it. The PC is communicating with a Remote I/O and I have to say the performance is great. The process in the container is running (soft) real time. Currently I’m checking if it is possible to replace physical controllers by remote I/O’s and run the Codesys applications on a docker server. If I’m going into this route the reliability of the server is very important (server down, complete installation down), is it possible to make the server redundant without needing 2 separate containers (including licenses), and maintaining the real time behavior? I’m not only expecting direct answers, if you have any idea or thought they are very welcome. Kind regards Alex
Last updated: 2025-09-03

Post by pernockham on Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication CODESYS Forge talk (Post)
I have a problem which I have identified with a device-update from 4.14.0.0 to (4.15.0.0-4.17.0.0) where the newer versions will stop any local access to the internal web page with the browser responding "The requested URL requires authentication". Setting the device back to 4.14.0.0. the web page will respond. Access to web page through Automation server is possible also for the newer version, but not "local" access. Runtime (Codesys control for linux SL) is on 4.17.0.0. I have tried to manipulate settings for 'Access-Control-Allow-Origin' '*' always; through nginx (normally a proxy_pass to localhost:8080). Also tested bypassing nginx by accessing 8080 directly with the same result.
Last updated: 2025-09-08

Post by davidbo on All the things needed for anonymous login to OPC UA CODESYS Forge talk (Post)
I thought I knew what I am doing, but something is missing what? From Device-Communication Settings select from drop down menu "Device" Select entry "Change Runtime Security Policy" Check the "Allow anonymous login" Select "Symbol Configuration" in your application In settings check "Support for OPC UA features" Check some of the values you want in your set Press the build button in the "Symbol Configuration" Press the button "Configure Symbol Rights" Make sure that Anonymous_OPCUAServer has access right to your "default set" From Device-Communication Settings select "Access Rights" in RemoteConnections-OPCUAServer Anonymous_OPCUAServer should be given modify and view rights I suppose. I can connect with UaExpert but I cannot see my Application or browse my values. What is missing?
Last updated: 2025-09-10

Post by alexgooi on Licensing info not available. CODESYS Forge talk (Post)
Dear Forum I have the following config: Codesys_IDE 3.5.20 Codesys_Virtual_Control 4.13 Codesys_License_Server 4.13 I know these are not the newest versions, but in my mind these should work. I have the same problem here. I have the license server installed on the host, and in the docker container(Codesys virtual control) I'm able to ping the license server. In the /conf/codesyscontrol/CODESYSControl_User.cfg I have added the following config: [CmpCodeMeter] EnableNetLicenses=1 LicenseServer.1="ip address of the host" I have tried it via the wbm web-page. I can create new license containers over there, but still no luck. I also have tried to run the docker container with the -s "server_IP" command. I have searched for some tutorial's but I couldn't find it. If anyone has some clue or can give me a push in the right direction it would be very very welcome!
Last updated: 2025-09-29

Post by alexgooi on Licensing info not available. CODESYS Forge talk (Post)
Thank you for your quick response, I have updated to the 4.17.0 (Virtual control and the license server). Now I am able to see the softcontainer from the Codesys IDE. But when I want to activate the license I get the following message: Licensing info not available. The device does not support this service (See picture). I then tried to active it via the WBM service like you suggested. But when I try this is get an error (see picture for error). I also tried to put RTS- in front of the serial number, but when I try this I get an error that the serial number is not correct. I think I'm getting closer, but I'm not there yet.
Last updated: 2025-10-01

Post by kevinl on RevPi Connect RS485 CODESYS Forge talk (Post)
I figured this out on my own with this logic: usually the Serial port on a Raspberry pi is on /dev/ttyUSB0 then you need to set linux.DeviceFile=/dev/ttyUSB in codesys you then must set com port to 1 so i assumed codesys subtracts 1 from the number and adds this to the filename... (in code it would look like this: var comPort : byte := '1'; linuxDevice : string := '/dev/ttyUSB'; filename : string; end_var filename := concat(linuxDevice, (to_string(comPort-1)); filaname then is /dev/ttyUSB0 RevPi uses ttyRS485 as Serial port so you must remove the last number from the name and set the com port to this number +1 i hope this is understandable ;-)
Last updated: 2023-12-11

Post by niloufar on Execution Order of Function Blocks CODESYS Forge talk (Post)
Hi, Our program incorporates various function blocks and programs written in different languages such as St and SFC. They implement numerous actions and methods using different languages from their function blocks. My question is whether the execution order of function blocks is associated with the programming languages used. I understand that cycle time can be configured in the task configuration, but I'm curious if there is a specific sequence order of execution for function blocks written in different languages. For example, all function blocks in (ST) are executed first, followed by the execution of (SFC). Specifically, when the function is written in (ST) and the action is implemented in (SFC). I modified all function blocks in the main PLC program and configured a task configuration for the main program.
Last updated: 2023-12-13

Post by royw on Profinet library for C# CODESYS Forge talk (Post)
Hi, I don't know if I'm in the right place or if it's even possible... I'm looking for a way to address a Profinet device with Record Read and Write from my own PC. I actually only need very few commands to configure our device. This means setting the MAC address and a serial number. We would like to do this from a C# program. Now we are looking for a library or something similar. Since you can do it from Codesys, I thought there might be a DLL or something similar that you could use for this. As I said, we don't want real-time queries of the cyclic data but only record read/write. Does anyone have any helpful hint? Thanks in advance
Last updated: 2023-12-22

Post by idalu on Profinet PN_Controller Issue, Network Adapter CODESYS Forge talk (Post)
i have a problem with Profinet on my project. I'm using Codesys RTE 3.5.19.50. When i download program to controller the ethernet is ok, PN_Controller is ok but every device i'm trying to connect is red with error "DCP no RealStationName". When i'm trying to Scan for Devices on PN_Controller there are no devices found. I have installed Codesys driver CmpEt1000Drv to my network adapter (i'm sure it is right intel pro 1000 model). I have noticed that when i installed codesys driver i'm no longer able to ping this network adapter (i can ping it when intel driver is installed). On my previous projects with runetimes i can ping it even with codesys driver installed. I have also tried to do downgrade of everything to version 3.5.19.20 and it not helped.
Last updated: 2024-01-17

Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime CODESYS Forge talk (Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31

Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime CODESYS Forge talk (Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31

Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime CODESYS Forge talk (Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31

Post by dhumphries on No source code available CODESYS Forge talk (Post)
Try using an Ethernet/IP scanner instead of an adapter, I'm guessing the 2 devices you're trying to communicate with are adapters, you have to have a scanner somewhere and Codesys should be a scanner. I don't know why you're getting the error, you should be able to use your Ethernet port as an EthernetIP adapter (although I've never had a reason to try,) but it's probably not what you wanted to do, unless you're connecting to another PLC that is a scanner. Good luck configuring the devices you're trying to connect to, it will be a lot easier if you have an .EDS file instead of starting with a generic module, even with an .EDS it can be tricky getting the communication working.
Last updated: 2024-02-03

Post by arundara on OPC UA Server Stops after 5 consecutive disconnections of ethernet port CODESYS Forge talk (Post)
Hello Every one, During testing of OPC UA communication between UA Expert software and the CODESYS SoftPLC on a Linux environment, an observation was made. When the Ethernet cable was disconnected and reconnected with 2-minute intervals, on the 5th attempt, the OPC UA connection failed to establish in UA Expert software. At this juncture, restarting the CODESYS SoftPLC enabled the reestablishment of OPC UA communication. The same result was obtained when testing on a Raspberry Pi SoftPLC. What is the reason behind this phenomenon? and whether there are settings to stop this behavior? Please help. Thanks & Regards.