Post by chris12345 on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
Hello everyone, I am using SP19 patch 2 on a Kunbus device with runtime package 4.9.0.0. I am having the same problem as mentioned above. With the FB File.open I get the FILE_OPERATION_DENIED error. I have also tried the path /var/opt/codesys/PlcLogic. Any advice? Chris
Last updated: 2023-10-17
Post by awatson on How to change keyboard layout on the virtual keyboard?
CODESYS Forge
talk
(Post)
I got it all working nicely based on the demo templates - edit my own numpad and screen keyboards - plus go the keyboard working on the login dialog (didn't work before!)
Last updated: 2023-11-17
Post by open on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Hi @ph0010421, I tried the program the TimeTaken is calculated when stop is triggered. I want the TimeTaken to be continuously calculated and counting when a BOOL variable is true. I tried to program this way: Declaration: PROGRAM PLC_PRG VAR bStartStop: BOOL := FALSE; // Start/Stop button bReset: BOOL := FALSE; // Reset button bRunning: BOOL := FALSE; // Flag indicating whether the stopwatch is running tStartTime: TIME; // Variable to store the start time tElapsedTime: TIME; // Variable to store the elapsed time END_VAR Implementation: // Main program logic IF bReset THEN // Reset button pressed, reset the stopwatch bRunning := FALSE; tElapsedTime := T#0s; ELSIF bStartStop THEN // Start/Stop button pressed, toggle the running state IF bRunning THEN // Stop the stopwatch bRunning := FALSE; ELSE // Start the stopwatch bRunning := TRUE; tStartTime := tElapsedTime; END_IF; END_IF // Update the elapsed time when the stopwatch is running IF bRunning THEN tElapsedTime := tElapsedTime + T#1s; // Adjust the time increment as needed END_IF However counting of the seconds is not accurate. I tried changing the main task cycle time interval to 1000ms. The counting of seconds become slower. (see attached) Please help
Last updated: 2023-12-08
Purchased the CODESYS SoftMotion SL License but the status of my SM_Drive_RaspiStepper shows license missing or invalid
CODESYS Forge
talk
(Thread)
Purchased the CODESYS SoftMotion SL License but the status of my SM_Drive_RaspiStepper shows license missing or invalid
Last updated: 2022-08-16
Post by lostcontrol on Remote Ethernet/ip Adapter communication with scanner running on codesys
CODESYS Forge
talk
(Post)
is the bus running.? what type of values/IO is the adaptor providing? do you have a map of the data layout? are you actually looking at the right offset?
Last updated: 2023-12-16
Post by reinier-geers on Raspberry Pi
CODESYS Forge
talk
(Post)
I Bought a Raspberry Pi licensens. Downloaded the software. Install it on version 19. Start version 19. Whant to set a licensens to the raspberry Pi. Scan the network. But No Raspberry pi. I can Ping the Raspberry Pi. Whats wrong ?
Last updated: 2023-12-28
Post by dkugler on Ramp function
CODESYS Forge
talk
(Post)
The util.RAMP_INT and util.RAMP_REAL from Codesys have an input for the start value. What is the advantage of this OSCAT ramp instead of the Codesys util lib?
Last updated: 2024-01-10
Post by pr0schwein on Driving the slave axis across master's zero point - caming
CODESYS Forge
talk
(Post)
Is there a way to move the slave axis across the zero point of the master axis with variable start and stop points? For example: Slave start at 270Β° and end at 50Β°. thanks :)
Last updated: 2024-01-18
Post by ekristoffe on Problem install codesys 3.5.17 SP 30 with Codesys Installer
CODESYS Forge
talk
(Post)
hello, it seem the installer 2.2.1 fix this problem. please try after updating codesys installer (if the auto update doesn't show the latest version available, you may have to download manually from the codesys store).
Last updated: 2024-01-26
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I put the cross reference at the bottom of the pictures. It is not being written to elsewhere. I have tried the execute block too.
Last updated: 2024-01-26
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I put the cross reference at the bottom of the pictures. It is not being written to elsewhere. I have tried the execute block too.
Last updated: 2024-01-26
Post by totorovic on Project loses 'Download time' information
CODESYS Forge
talk
(Post)
Hello, It happens that the offline project (the IDE one) loses the Download information. Because of this the code has to be download again. Is it possible to force this info somewhere? Is it possible to ignore it? How can I solve this ? Thank you
Last updated: 2024-02-13
Post by dtamm on How to read string from CharBufferPtr?
CODESYS Forge
talk
(Post)
Solved it! The simple answer was to declare a variable as POINTER TO STRING and assign the GetMessage result to that variable. Then, the ^ operator can be used to extract the message as string.
Last updated: 2024-02-21
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi TimH Thanks for the information, I thought that was the case so have stepped through the code and found an error that wasn't closing the port, therefore hCom was increasing. Thanks
Last updated: 2024-03-28
Post by simonh on Datasource OPC UA Client error ID:7012
CODESYS Forge
talk
(Post)
Hello, did you find the solution for the communication?Has the communication between the two been successful? if yes, can you please share me your solution since i have similar issue now. Thanks.
Last updated: 2024-04-04
Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
Ok yes now the loop has stopped when I set sum to zero before the for loop. Why will it retain the sum value from the last call?
Last updated: 2024-05-06
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20