Post by aniket-b on EtherCAT drive not moving
CODESYS Forge
talk
(Post)
I have EtherCAT drive communicating properly without an error but when I use MC_JOG function, it is not moving at all, I can use MC_Power function and drive does respond to that but other functions are not working,. Please suggest what is wrong here.
Last updated: 2024-03-04
Post by mandeepahujaifm on IFM CR711S Version Mismatch
CODESYS Forge
talk
(Post)
Please send an email to info.us@ifm.com and they shall provide you with the correct information. Alternatively you can check the website for latest packages. https://www.ifm.com/us/en/product/CR711S?tab=documents
Last updated: 2024-03-05
Post by seweb on NTCIP
CODESYS Forge
talk
(Post)
Hello everybody, In an upcoming project we are supposed to control a display board via NTCIP. Unfortunately, I have not yet found out whether this is possible with CODESYS. Are there any libraries for this in CODESYS? Best regards
Last updated: 2024-03-14
Post by eschwellinger on No work Control Torque Codesys with Drivers M751 Control Techniques
CODESYS Forge
talk
(Post)
you need to check this in the Cotrol tech specifc SoftMotion lirary in CODESYS library manager. There is embedded a pdf inside this library.
Last updated: 2024-03-14
Post by fless on See only variable
CODESYS Forge
talk
(Post)
either you have "Insert with namespace" enabled in the SmartCoding options or your GVL_GLOBAL starts with {attribute 'qualified_only'} btw it's considered good practice to put the namespace in front of the variable. you could have variable with the same name in your PRG or FB.
Last updated: 2024-03-14
Post by lordsteve on OPC UA certificate upgrade
CODESYS Forge
talk
(Post)
Hi, I have the same issue. It should be possible to create a certificate without using Codesys IDE. The functionality of the security agent could be handled in some fb. Can anyone here give the right hint?
Last updated: 2024-03-15
Post by fleaplc on MPC predictive control
CODESYS Forge
talk
(Post)
Hi all, is there some library for Codesys to handle predictive models (MPC) such as https://www.mathworks.com/help/mpc/gs/what-is-mpc.html https://en.wikipedia.org/wiki/Model_predictive_control
Last updated: 2024-03-17
Post by thewizard8 on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi thanks once again, Yes it supports because using python scripting I'm able to send data from the rasberry raspberry and receive it on my pc and vice versa (Image attached). But when using the CoDeSyS I just got red flags. Any light on this problem?
Last updated: 2024-03-19
Post by fraccaroli on New Codesys Library Dependencies
CODESYS Forge
talk
(Post)
Hello, you probably fixed in this meanwile, but I think your problem comes from dependencies of other libraries. I see in the Project column of errors the "caa types extern" and "caa fb factory", that both have dependencies. Try to check there. Regards, Francesco
Last updated: 2024-03-21
Post by esave on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Thank you very much Florian The SoftMotionLight package is actually more expencive than the normal SoftMotion. What is exactly the difference? Does my PLC need to be compatible with SoftMotion or does this work with any PLC?
Last updated: 2024-03-22
Post by timvh on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
You should only open de COM port once and then leave it open. This hCom should not keep on incrementing. (off course when you are done communicating, you need to close the COM port)
Last updated: 2024-03-22
Post by florian on Error while using Codesys SP19 Patch 4 on Windows 11
CODESYS Forge
talk
(Post)
Hi, you should have 'CODESYS Installer,' there you can manage your packages and installations. The version number looks like a softmotion package, try to install it. Or repair your whole installation with the CODESYS Installer.
Last updated: 2024-03-26
Post by markosrod on Problem with the license of libraries IIoT
CODESYS Forge
talk
(Post)
hello people, im having this issue when i try to validate the libraries. im using a device and a softcontainer. I tried with two different Keys and nothing. Please help with this.
Last updated: 2024-04-04
Post by dawidr on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module
CODESYS Forge
talk
(Post)
Did you manage to solve the problem with time out? I got the same issue and I've no idea what I'm doing wrong.
Last updated: 2024-04-07
Post by dawidr on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module
CODESYS Forge
talk
(Post)
Did you manage to solve the problem with time out? I got the same issue and I've no idea what I'm doing wrong.
Last updated: 2024-04-07
Post by mibkid17 on Ethernet Adapter message: Adapter configured. Open all connections
CODESYS Forge
talk
(Post)
Trying to control 525 with codsys the info from C-4 section. i should input the value in user defined parameters? in the generic device
Last updated: 2024-04-09
Post by januar on Trend recording build error - the variable "arrTraceMgrVariablesImpl" is too large
CODESYS Forge
talk
(Post)
Hi Adel, No, I just update all to the latest version and it is working. Kind regards, Januar
Last updated: 2024-04-10
Post by plumper on License problem gateway
CODESYS Forge
talk
(Post)
I have the same problem. Obtained new license without success. Codesys 3.5 SP 16, soft container. I would be grateful for quick help as we have to deliver equipment. Best regards
Last updated: 2024-04-16
Post by nano on Functional block
CODESYS Forge
talk
(Post)
u can use internal variables by passing it thru setter/getter. thats the way to go. for that add it by rightclick on fb and create propertie
Last updated: 2024-04-17
Post by tomas111 on Text List Fallback Value
CODESYS Forge
talk
(Post)
What version of codesys? Need to avoid in any specific element? Try writing %s in the text, it should work. Or better yet, attach a screenshot.
Last updated: 2024-04-17
Post by valenting on Problem with Licenced Software Metrics
CODESYS Forge
talk
(Post)
Hi, I can't compile my code with SP20, but when I use the "read current metrics from device" with SP20 I get the following, with "not yet supported" for the visualization part Is it supposed to be like this ?
Last updated: 2024-04-24
Post by damian177 on Visualization - table element
CODESYS Forge
talk
(Post)
Hi, In my application I use table elemnt with filled by STRING ARRAY. I would like to implement the following functionality : When I click on second row, that this row will be cleared. Anyone can help me?
Last updated: 2024-04-25
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
By browser is not working. Tim suggestet to use Codesys and stick in the laptop. Thats working. But now with a stick with licence but no running motion.
Last updated: 2024-04-25
Post by k2saki on CNC Override speed. SMC_Interpolator.dOverride is working ?
CODESYS Forge
talk
(Post)
Hello. I have a question about override of moving speed. I am testing G-Code in Simulation mode. I set SMC_Interpolator.dOverride <--- 0.5, 1.0, 2.0 when Interpolator is working But SMC_Interpolator.dVel(speed) did not changed at all. Am I missing something to take effect ?
Last updated: 2024-05-01
Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection)
CODESYS Forge
talk
(Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND