Post by niloufar on Execution Order of Function Blocks
CODESYS Forge
talk
(Post)
Hi, Our program incorporates various function blocks and programs written in different languages such as St and SFC. They implement numerous actions and methods using different languages from their function blocks. My question is whether the execution order of function blocks is associated with the programming languages used. I understand that cycle time can be configured in the task configuration, but I'm curious if there is a specific sequence order of execution for function blocks written in different languages. For example, all function blocks in (ST) are executed first, followed by the execution of (SFC). Specifically, when the function is written in (ST) and the action is implemented in (SFC). I modified all function blocks in the main PLC program and configured a task configuration for the main program.
Last updated: 2023-12-13
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by dhumphries on No source code available
CODESYS Forge
talk
(Post)
Try using an Ethernet/IP scanner instead of an adapter, I'm guessing the 2 devices you're trying to communicate with are adapters, you have to have a scanner somewhere and Codesys should be a scanner. I don't know why you're getting the error, you should be able to use your Ethernet port as an EthernetIP adapter (although I've never had a reason to try,) but it's probably not what you wanted to do, unless you're connecting to another PLC that is a scanner. Good luck configuring the devices you're trying to connect to, it will be a lot easier if you have an .EDS file instead of starting with a generic module, even with an .EDS it can be tricky getting the communication working.
Last updated: 2024-02-03
Post by arundara on OPC UA Server Stops after 5 consecutive disconnections of ethernet port
CODESYS Forge
talk
(Post)
Hello Every one, During testing of OPC UA communication between UA Expert software and the CODESYS SoftPLC on a Linux environment, an observation was made. When the Ethernet cable was disconnected and reconnected with 2-minute intervals, on the 5th attempt, the OPC UA connection failed to establish in UA Expert software. At this juncture, restarting the CODESYS SoftPLC enabled the reestablishment of OPC UA communication. The same result was obtained when testing on a Raspberry Pi SoftPLC. What is the reason behind this phenomenon? and whether there are settings to stop this behavior? Please help. Thanks & Regards.
Last updated: 2024-02-13
Post by bschraud on Zielsystem stimmt nicht mit dem verbundenen Gerät überein
CODESYS Forge
talk
(Post)
Hallo, nach einer Umrüstung des RPi auf SSD habe ich den RPi neu aufgesetzt. Nach dem Installieren der Runtime (4.11.0.0 raspberry, all) auf den RPi kann ich das Gerät nicht mehr verbinden. Die Fehlermeldung lautet "Das gewählte Zielsystem 'Codesys Control for Raspberry Pi MC SL' stimmt nicht mit dem verbundenen Gerät 'Codesys Control for Raspberry Pi 64SL' überein. ID-Diskrepanz: Ausgewählt=000 0011, Online=0000 0012" Bei der Konfiguration des Laufzeitsystems kann man nur Multicore 64-bit (Aarch64) auswählen. Beim Aktualisieren des Gerätes im Gerätebaum habe ich Raspberry Pi MC SL in der Version 4.11.0.0 ausgewählt. Diese Version habe ich auch ausgewählt, weil nur diese Version für den produktiven Einsatz zugelassen ist. Die codesys Version ist frisch installiert, also 3.5.19.60 Vielen Dank für Ihre Hilfe
Last updated: 2024-03-08
Post by francescoc on Logger in ms
CODESYS Forge
talk
(Post)
Hi, I cannot find any documentation regarding the codesys configuration file. I modified this part to have log files saved to disk: [CmpLog] Logger.0.Name=LOGS/PlcLog Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=20000 Logger.0.MaxFileSize=5000 Logger.0.MaxFiles=10 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314;Set the timestamp to RTC ;Logger.1.Name=/tmp/CommLog ;Logger.1.Enable=1 I need to have milliseconds in the timestamp as well. What value should I use instead of 0x314? Is there any documentation regarding this file? Thank you
Last updated: 2024-03-16
Post by mani-i4point0 on Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Post)
Hi, I am running Codesys Runtime by purchasing 'Codesys control for raspberry pi MC SL', I am trying to use the Variables from my GVL's. Few of the variables used as a Pushbutton form the Visualization. These 'BOOL' Variable getting unlatched automatically even though there is no write function in the Overall project. All of them are 'Read' functions, at the same time few other BOOL variable behaviors are seems to be fine. I have tried, clean all and download, serval time restarted the hardware. Happy to share any any information. Your input to resolve this issue would be highly appriciated. Version Details: codesyscontrol 4.8.0.0, armhf codesyscontrol based on SDK 3.5.19.0
Last updated: 2024-03-20
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I recognized that I have to start the two services "/etc/init.d/codemeter" and "/etc/init.d/codemeter-webadmin" in the docker container as well. If I do so, then the command "cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. So this time there is no indication any more that "Codemeter is not running". But still we are getting the error when using the license manager in CODESYS development system.
Last updated: 2024-03-21
Post by bschraud on Unerwünschte Username- und Passwortabfrage im Browserfenster
CODESYS Forge
talk
(Post)
Hallo, nach der Portierung meiner Applikation von Codesys Version 3.5.18 auf 3.5.20 habe ich u.a. folgende Baustelle: Wenn in der Datei /etc/CODESYSControl_User.cfg die Einträge [SysProcess] Command=AllowAll und [CmpWebServerHandlerV3] AllowFileTransferServices=1 ergänzt werden, startet die Webvisu mit einer Login Abfrage. Die Webvisu soll aber (wie bisher auch) ohne Benutzeraktion starten. Den Browser für die Webvisu rufe ich mit dem Eintrag @firefox --kiosk --private-window localhost:8080/webvisu.htm in der autostart Datei auf. Wie kann man die Login-Abfrage wieder loswerden? Die Runtime läuft auf einem RPi mit Kernel Version 6.1.21 (aarch64) Vielen Dank für die Hilfe
Last updated: 2024-04-02
Post by dhumphries on How to determine code size
CODESYS Forge
talk
(Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05
Post by sachem on Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Post)
Good afternoon. I am working with a weidmuller uc20-wl2000 controller, using a codesys license. We made a ladder code to control a process, and it works well, but we want some variables to remain stored even when the controller is turned off. We tried to use retain variables, but at the time of loading the program, when we went offline from the controller, the program was deleted, it did not remain in the controller, and in the same way if we turned off the controller. In addition to this, when we tried to program it again, the program would not stay loaded and began to present errors with the opc-ua communication. What could be causing this problem? How can we maintain the values of the variables without damaging the program or affecting the controller? thank you
Last updated: 2024-04-10
Post by valenting on Can't use new licensing with Raspberry Pi
CODESYS Forge
talk
(Post)
Hi, I'm using Codesys control for Raspberry Pi in the latest version (4.11.0.0) When I try to install a license with the new application-based licensing, I have an error "returncode 403046401" (using codesys SP18) I updated to codesys SP20, and now I get the following error: "The selected conainer [0]: SN=..., Version=1.18, Chip=0, Rev=0 does not fit to your ticket. Please select a suitable one." The license I'm trying to install is a Codesys Control Basic L license, with a Codesys Visualization L option, according to the needs of my application. What can I do to activate my license ?
Last updated: 2024-04-22
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Good morning @eschwellinger, After some research I found out that the problem is the preinstalled CodeMeter on Raspberry Pi. As I mentioned the CodeMeter was installed on the Raspberry because I use a license from other vendor that needs the CodeMeter to be installed. The problem is that when I uninstall the CodeMeter from Raspberry I am able to detect the dongle from CODESYS and everything works as it should be but now the other product can not detect its own license. When I reinstall the CodeMeter I am back to the initial problem. Is there a way to overcome this conflict through CODESYS?
Last updated: 2024-04-24
Post by starmaxou on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
CODESYS Forge
talk
(Post)
Hi everyone, I'm trying to install the CODESYS Control for Raspberry Pi SL package. The computer with CODESYS software is offline for security reasons. So, I downloaded the package on another computer and installed it manually. But this package has dependencies packages: CODESYS.Control SL Extension Package, V4.0.0.0 CODESYS.Control SL Deploy Tool, V4.10.0.0 As I said, the computer with CODESYS is offline. I cannot use the package installer to search for these packages. I did not find them in Codesys Store with another computer. Do you know where to find and download them? Thank you in advance for your help!
Last updated: 2024-05-30
Post by fajean on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
4.11 appears to solve the problem. Thanks for your help. I had first installed the 64-bit version of RPiOS, but looking at various posts and the product's page on the store which only lists 32-bit compatibility, I downgraded to the 32-bit version. I did this before trying 4.11, and it did not solve the problem. Thus my working system is 32-bit, and I am wondering if I can go back to 64-bit or not. An 64-bit OS is not listed as compatible on the store's web page, but when installing there actually is a 64-bit version listed (automatically chosen when installing on 64-bit, but otherwise greyed out). Is 64-bit supported and the website is out-of-date, or is that some kind of work-in-progress?
Last updated: 2024-06-13
Post by mborchert on PFC100 Error "Bus not running"
CODESYS Forge
talk
(Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17
Post by alimans on Unrecoverable SoftMotion state after switch to PreOp
CODESYS Forge
talk
(Post)
For anyone still experiencing this issue, here’s how I managed to solve it: Symptoms: 1. Sometimes, on the first start of CODESYS Runtime, the modules fail to run. 2. After disconnecting and reconnecting the communication cable, the drive does not start again. 3. MC_Reset cannot clear the fault. Solution (what worked for me): 1. Check the axis communication using the SMC_CheckAxisCommunication function block (FB). 2. If CheckAxisCommunication.eComState of the axis is equal to or higher than SMC_CommunicationState.SMC_COMSTATE_BASE_COM_INITIALIZATION, then 3. Use the SMC3_ReinitDrive function block to reset the drive — and it works. For more information, refer to the official CODESYS documentation: 👉 https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/DriveInterface/AXIS_REF/SMC3_ReinitDrive.html
Last updated: 2025-10-23
Post by aria13 on Has anyone fed ESP32 sensor data into CODESYS (via MQTT/Modbus)?
CODESYS Forge
talk
(Post)
Has anyone tried sending live sensor data from an ESP32 into a CODESYS runtime (for example via MQTT gateway or a Modbus bridge) to trigger PLC logic? I was reading an ESP32 → MQTT tutorial (https://www.theengineeringprojects.com/2021/11/esp32-mqtt.html) that shows how easy it is to publish sensor data from an ESP32, and I’m wondering how practical that is when tying the stream into industrial control software like CODESYS. I’ve also seen Arduino forum threads where people relay sensor streams to MQTT brokers and Raspberry Pi projects that bridge MQTT→Modbus, so I’m mainly curious about real-world issues: reliability, message latency, and simple patterns you’d recommend for safe PLC integration. Any tips, examples, or gotchas from folks who’ve done this?
Last updated: 2025-10-29
Post by miltos on licensing question
CODESYS Forge
talk
(Post)
Greetings to all, I'm working on a webvisu project on control win V3 x64 runtime, and have purchased 3 licenses for my application. -Codesys Control Standard M -Codesys Visualization L -Codesys Communication M I have them installed on a Codesys usb dongle When I try to download the program, a login error window appears with the message "No valid license found for the webvisualization". The control win v3 communicates with 3 plc, and have enabled communication over codesys V3 communication by adding one datasource for every plc in the datamanager. If I remove the data manager from the project, the rest of the visualisation can be downloaded normally. Do I need to purchase another License and which one? Please find attached the software metrics and the error screen.
Last updated: 2025-10-31
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
The machine I'm currently using (Celeron J1900) already has the Kernel RT patch. I checked the performance according to the documentation. After running CyclicTest for 4 cores, the value for each core is around 6-7. I went through the entire process according to the documentation (I envy the TaskMonitor results in the documentation). The documentation states: "CODESYS Virtual Safe Time Provider The CODESYS Virtual Safe Time Provider is a standard interface that the user can use to transfer a second and external time base to the CODESYS Virtual Safe Control. The implementation is done as a client, which must run on another system with an independent time base." How do I implement this? I've been struggling for two weeks now - I'm too old to give up.
Last updated: 2025-11-17
Post by msirotkin on EtherCAT status errors
CODESYS Forge
talk
(Post)
Hello, I'm trying to understand the reason for the many errors on the EtherCAT master status page. If we set the cycletime to 1ms we see a lot of rxerrors and lostframes, but the send and recive times are quite good (see attachement). And the status of the EtherCAT bus is good (no other errors, all is green, slave has no errors) But when we set 2ms cycletime the lostframe errors are gone, but periodically increses rxerror counter (see attachement). The questions is, what do these errors actually mean and what we can do to get gid of them? Linux RT, imx8, Codesys runtime for ARM 3.5.21.10, Ethercat 4.10 Thanks
Last updated: 2025-11-25
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
The option to update "Control for Linux SL" is not shown in the "deploy control SL tool", I can see and update the gateway but not the control (3.5.21 SP4). Has the way to update control SL changed? In the process of fault finding I removed the control SL entirely from my target, then I had to revert to version 3.5.21.0 SP 1 to re-install "Control SL 4.17.0.0". So I thought it was just a matter of using SP1 to update also to 4.18.0.0, but after installing the files for 4.18.0.0 in the SP1-version, the behavior was identical to SP4, ie no Control for Linux SL shown in the deploy tool.. See screenshots.
Last updated: 2025-12-19
Post by mait-tim on Drive communication errors
CODESYS Forge
talk
(Post)
With a machine I'm working with i get a communication error when I'm updating some softstop limits. As soon as I update the code the drives do not want to operate. Using the MC_readStatus I'm receiving errors as soon as i want to start a movement. Using MC_ReadAxisError i see that i receive error 131, no response. With a SMC3_ETC_ReadParameter_CoE i do not recieve any driver errors. Does anyone know how i can figure out what the error is and how to solve it. When i go back to the old software no errors occur. Im working with a legacy machine running a Beijer PLC with some Mitsubishi drives. running on Codesys 3.5 SP10. the runtime version is probably 3.5.3. The drives are all Ethercat Drives (CoE). All using the SM3_drive_ETC libary and the SM3_basic library.
Last updated: 2025-12-22