Post by k2saki on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment . CODESYS Forge talk (Post)
I'm using CAD/CAM that outputs GCode with G01 many short segments from NURBS Curve, only X-Y axis. But CODESYS CNC motion seems much slower ( or stop-go motion ) in simulation mode than F-Value (I checked value from SMC_Interpolator - dVel ). In GCode G01, F value is F500, but movement is very slow, actual speed (dVel) is between 0 to 30 back and forth. I think very old CNC can move like that, but nowadays, a lot of CNC can move smoothly to process free curve ( somethimes option switch ) I tried to use G51 Dxx but I got the same result. My questions are 1) How do I improve CODESYS CNC motion in this case ? 2) How can I graph the sampling from dVel of SMC_Interpolate in CODESYS? From my GCode N2006 G01 X1.4364 Y-14.6847 F500 N2007 G01 X1.6759 Y-14.6768 N2008 G01 X1.9152 Y-14.6486 N2009 G01 X2.1547 Y-14.6400 N2010 G01 X2.3943 Y-14.6090 N2011 G01 X2.6336 Y-14.6002 N2012 G01 X2.8732 Y-14.5716 N2013 G01 X3.1127 Y-14.5634 N2014 G01 X3.3520 Y-14.5410 N2015 G01 X3.5915 Y-14.5336 N2016 G01 X3.8308 Y-14.5307 ... Thansk.
Last updated: 2024-04-29

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by danwoodlock on Rpi zero w lost license after 4.11 update CODESYS Forge talk (Post)
Hello all, Encountered an issue with my zero which seems to have happened after the 4.11 update. It now runs in demo mode (2hr) and I am trying to see what the appropriate steps are prior to contacting codesys directly. Background: I recently did a fresh install of w11 on my pc, so it seems "c:\ProgramData\CODESYS\Licenses\" only has information related to my pi5, which I licensed just this past Friday. I have all my license documentation about my rpi zero as far as the emails received, but when I try to claim using the ticket number it says its already been used, or something to that effect, which it was. Currently trying to perform device license reader, which is taking some time.
Last updated: 2024-04-14

Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred! CODESYS Forge talk (Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08

Post by amy123 on Any guides on using Codesys containers in Docker? CODESYS Forge talk (Post)
I had an issue aswell, I was trying to use docker and got stuck on the specific line ' Downloading https://download.microsoft.com/download/9/5/A/95A9616B-7A37-4AF6-BC36-D6EA96C8DAAE/dotNetFx40_Full_x86_x64.exe' within install2.sh - which is actually from the https://raw.githubusercontent.com/Winetricks/winetricks/master/src/winetricks, winetricks_selfupdate(). Would love to know if anyone has a known solution. Only other thing I can think is to download winetricks +.net, update the winetricks to point to the downloaded .net? Granted Im not too savy with Docker so I have been struggling on figuring that part out- would love any suggestions!
Last updated: 2024-05-19

Post by dekelec on The current baud rate could not be determined in CR0020 IFM with maintenance tool CODESYS Forge talk (Post)
It could be a problem with the cable pinout on either side: 9 pin D-SUB connector (male) - PC side Pin Potential: 1 n.c. 2 RxD 3 TxD 4 n.c. 5 n.c. 6 GND 7 n.c. 8 n.c. 9 n.c. Shell Shield Check if TxD and RxD cross between pins 2 and 3 (what is the Recive signal/wire to one device it's a Transmit signal/wire for the othe device) or with COM port settings: Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow controll: None
Last updated: 2024-07-09

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Ok, here are the libraries I use. First of all, try to get the ADS1115 to run completely on its own. Without MUX or other sensors. As muxboard I use this one: https://www.digikey.de/de/products/detail/sparkfun-electronics/BOB-16784/12714950?utm_adgroup=&utm_source=google&utm_medium=cpc&utm_campaign=PMax:%20Smart%20Shopping_Product_Zombie%20SKUs&utm_term=&productid=12714950&utm_content=&utm_id=go_cmp-18521752285_adg-_ad-__dev-c_ext-_prd-12714950_sig-Cj0KCQiA88a5BhDPARIsAFj595gkPXWPT8aa-EixL97BDWjO988WDhcx-iHOVbqb_H8CLpHBcwLuJW0aAu1JEALw_wcB&gad_source=1&gclid=Cj0KCQiA88a5BhDPARIsAFj595gkPXWPT8aa-EixL97BDWjO988WDhcx-iHOVbqb_H8CLpHBcwLuJW0aAu1JEALw_wcB All other boards don't work for me either. The terminating resistor is missing Important: Before you install the drivers, remove all other device drivers. My drivers are all located in ‘Raspberry I2C MUX_11_2023’
Last updated: 2024-11-11

Post by pistola on Visualization Size - Set Layout CODESYS Forge talk (Post)
I feel like this is a setting issue and I can't seem to find the right setting. I have a new project that I'm looking to add visualizations to however when I select my template size (1280 x 800) I make sure in my properties under the visualization tab, I have "Use specified visualization size" selected and my width set at 1280 and height set at 800. Now within my visualization editor I can't see to get the size outside of my template to grey out. I've attached a PDF showing what I'd like the visualization editor to look like and what mine currently looks like. Any help would be greatly appreciated.
Last updated: 6 days ago

Post by damian177 on RPi, Codesys , RS232 CODESYS Forge talk (Post)
Hi, so far I have only used one com port - built-in interface in RPi - RS232 (dev/serial0) as COM1 in Codesys, and my CODESYControl_User.cfg have congiuration like below: [SysCom] Linux.Devicefile=/dev/serial portnum := COM.SysCom.SYS_COMPORT1 Actually I added to my Rpi Hat with 2xRS232 (SPI). - /dev/spidev0.0 and /dev/spidev0.1 How I should change my CODESYControl_User.cfg file to use added porta as COM2 and COM3 in Codesys ?
Last updated: 2023-10-05

Post by kleeswi on Fehlermeldung Objektverweis nicht in Objektinstanz CODESYS Forge talk (Post)
Last updated: 2023-10-23

Post by kleeswi on Fehlermeldung Objektverweis nicht in Objektinstanz CODESYS Forge talk (Post)
Last updated: 2023-10-23

Post by struccc on Release SP20 - Changes in behaviour? CODESYS Forge talk (Post)
Last updated: 2024-03-25

Post by stdenits on Set several bits in WORD CODESYS Forge talk (Post)
DEL
Last updated: 2024-04-23

Post by mani-i4point0 on CODESYS Development System V3 ( 3.5.19.70 ) on Windows Virtual Machine CODESYS Forge talk (Post)
Hi, I have a requirement where in need to install a CODESYS Development System V3 ( 3.5.19.70 ) on a Window 10 which is running in VM. Is there any limitation of functions and features of using CODESYS Development System V3 ( 3.5.19.70 ) installed in Window 10 which is running in VM. Please do advice. Best Regards, Mani
Last updated: 2024-05-14

Post by mani-i4point0 on CODESYS Development System V3 ( 3.5.19.70 ) on Windows Virtual Machine CODESYS Forge talk (Post)
Hi, I have a requirement where in need to install a CODESYS Development System V3 ( 3.5.19.70 ) on a Window 10 which is running in VM. Is there any limitation of functions and features of using CODESYS Development System V3 ( 3.5.19.70 ) installed in Window 10 which is running in VM. Please do advice. Best Regards, Mani
Last updated: 2024-05-14

Post by dhumphries on Rounding error in simple addition CODESYS Forge talk (Post)
Bump
Last updated: 2024-05-24

Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Hi, I wanted to use the Adafruit Hat for the Raspberry and get acquainted with Softmotion using servos for RC models. This did work great with Codesys 3.5.19 Patch 1, but with Patch 4 and 5 i get errors. I suspect changes in the SoftMotion library have broken dependencies in the legacy drivers, might that be true? Thanks for any hint, spiessli Here the error log: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.6.0.0 (3s - smart software solutions gmbh): GetStandardConfigParams AXIS_REF_SERVO: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-19

Post by arvind on communication CODESYS Forge talk (Post)
HI All past two weeks im trying to configure and establish communication between wago rs485 fieldbus coupler(750-315/300-000) with wago pfc 200 plc but not able to communicate can you peoples help me to configure and establish communication using codesys v3.5 and above
Last updated: 2023-08-19

Post by eschwellinger on RPI Zero w - Edge gateway cant install CODESYS Forge talk (Post)
ok now it is clear - this is a single core Pi Zero W. For this device there is no edge device available. But just for working with CODESYS it is not really needed and yes plc runs only for 2h unlicensed.
Last updated: 2023-09-13

Post by davidredondo on Send file from codesys to...... ftp, cloud, etc CODESYS Forge talk (Post)
Hi all, I am also looking for a solution to transfer a csv file from ifm HMI-PLC to some cloud and finally to node-red, for example. Do any of you advise me how to do it? Thanks
Last updated: 2023-11-08

Post by jinlee on Multiple WebVisu CODESYS Forge talk (Post)
Hi there, I am having a similar problem like you. I have 3 screens connected to one PLC. I have set 3 different URLs for them. But 3 of them are still dependent to each other. How can I make them independently ? Kind regards, Jin.
Last updated: 2024-01-25

Post by trycyclepower on Only single ehternet ip drive is communicating CODESYS Forge talk (Post)
Hi all, I have two ethernet IP drives not communicating together. If I disable one, then other one starts working. ENIPScnannerIOTak cycle is setup as 20ms. Also, PLC updating variables setting is on.
Last updated: 2024-03-08

Post by wiresplus on Remote connection to ifm PLC & HMI CODESYS Forge talk (Post)
I use these Teltonika routers with ZeroTier rather than OpenVPN - works better for me. I can show you how if you like?
Last updated: 2024-04-13

Post by andreag0 on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
Good to know. I am looking for some soluction to avoid PLC Handler and OPC-UA. Thank you.
Last updated: 2024-06-14

<< < 1 .. 168 169 170 171 172 .. 229 > >> (Page 170 of 229)

Showing results of 5716

Sort by relevance or date