Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
I’m trying to integrate a custom PLC into CODESYS so that it appears under the Device section. From what I understand, this requires a .devdesc.xml device descriptor file. I attempted to create the XML manually, but whenever I try to install it in order to generate a .package file, CODESYS crashes. CODESYS version: 3.5.21.20 Target PLC: Linux ARM64–based My questions are: Is there an official or easier way to generate a valid .devdesc.xml file for a custom PLC? Are there tools, templates, or examples that can help ensure the XML is structured correctly and won’t cause crashes? For Linux ARM64 targets specifically, is there a recommended starting point (e.g., modifying an existing device descriptor)? Any guidance or best practices for creating and packaging custom device descriptors would be greatly appreciated.
Last updated: 2025-10-06
Post by bbmussatto on Connetion with Topcon Opus B3 ECO Full display
CODESYS Forge
talk
(Post)
I have a Topcon Opus B3 ECO Full display and i wanna program it with codesys, but i cant connect it to the display. After creating a new project, i choose the device "Opus B3-B4-B6-3.5.19.50" that is already available in my version of codesys, but i think the problem is that my version of codesys or something else is not the same as the codesys runtime version running on my display. Can anyone tell me how i can see the codesys runtime version on my display? i tried looking in the settings (Daemon > CDS) on the display, but all i see is "N/A" for "Customer Number", "Customer Part Number" and "Customer Serial Number". Can anyone help me make this connection?
Last updated: 2025-10-07
Post by budd7566 on Text size suddenly changed
CODESYS Forge
talk
(Post)
Iv been working with a Deep Sea Electronics DSE840 for about 6 months. I have a development version of my program working with a state machine and a basic gui interface. I went to implement CAN and suddenly the text on the gui on the controller is much larger than before. I could flash old versions of my project and the text was the correct size, but if i renamed the project file, the text displayed would be large. The visualization in CODESYS always shows the expected size, but not the controller. I did a fresh install of CODESYS and even a new project with only one text box, I cant get the text size on the controller to match what is displayed in codesys to match. Any advice?
Last updated: 2023-12-09
Post by kevinl on RevPi Connect RS485
CODESYS Forge
talk
(Post)
I figured this out on my own with this logic: usually the Serial port on a Raspberry pi is on /dev/ttyUSB0 then you need to set linux.DeviceFile=/dev/ttyUSB in codesys you then must set com port to 1 so i assumed codesys subtracts 1 from the number and adds this to the filename... (in code it would look like this: var comPort : byte := '1'; linuxDevice : string := '/dev/ttyUSB'; filename : string; end_var filename := concat(linuxDevice, (to_string(comPort-1)); filaname then is /dev/ttyUSB0 RevPi uses ttyRS485 as Serial port so you must remove the last number from the name and set the com port to this number +1 i hope this is understandable ;-)
Last updated: 2023-12-11
Post by snhatton on OpC UA server on Raspberry Pi 64 SL runtime
CODESYS Forge
talk
(Post)
Good afternoon, After changing the security settings to: CommunicationPolicy: POLICY_BASICSHA256SHA256 CommunicationMode: ALL Activation: Activated UserAuthentication: ENABLED Then generate a new certificate on the device for the OPC-UA server from Security Agent->Device->OPC UA Server. Restart the runtime using tools->Update Raspberry Pi->Stop->Start for the changes to take effect. It may take a minute for the runtime to start. Initiate the connection from the UA server side. You should see a pop-up asking you to trust the certificate. Click on the button 'Trust Server Certificate'. Next, you should see a certificate in the quarantined folder of the security agent in CODESYS. Click and drag this from quarantined to trusted and then try connecting from UA expert to the device. These steps worked for me and my setup and I hope they can help you!
Last updated: 2023-12-11
Post by sumit on Remote Ethernet/ip Adapter communication with scanner running on codesys
CODESYS Forge
talk
(Post)
Hello there, I have my ethernet/ip adapter (from Texas Instrument) running on Texas Instrument Board and I have configured the scanner on codesys. I have mapped the I/Os and I can see (on wireshark) the frames coming from adapter but I don't see my input variables in scanner get updated, they just stay at 0. I wanted to see the real data that has been sent from adapter to scanner on codesys. I am not sure if the problem is in I/O mapping or there is a step/s that I have missed. I have attached the screenshot of my project for your ref. Thank you, Sumit
Last updated: 2023-12-15
Post by sumit on Remote Ethernet/ip Adapter communication with scanner running on codesys
CODESYS Forge
talk
(Post)
Hello there, I have my ethernet/ip adapter (from Texas Instrument) running on Texas Instrument Board and I have configured the scanner on codesys. I have mapped the I/Os and I can see (on wireshark) the frames coming from adapter but I don't see my input variables in scanner get updated, they just stay at 0. I wanted to see the real data that has been sent from adapter to scanner on codesys. I am not sure if the problem is in I/O mapping or there is a step/s that I have missed. I have attached the screenshot of my project for your ref. Thank you, Sumit
Last updated: 2023-12-15
Post by user3000 on Can't find an Extended Pulse Timer (TP and LTP)
CODESYS Forge
talk
(Post)
I came up with an FBD that seems to be working, although it may not be a true Retriggerable Pulse timer. There may be some delay associated with the two MOVE functions and ADD function I incorporated. I'd be interested if anyone is able to come up with something cleaner. I am surprised that this is not a built-in function block of the CodeSYS library. This is a common feature of multi-function timer relays. I also attached a page from the cut sheet of a Schneider relay that shows 10 timing functions. Looks like the CodeSYS library has built-in function blocks for only 3 of the 10.
Last updated: 2023-12-21
Post by fajean on Issues with "Add all instance path"
CODESYS Forge
talk
(Post)
In the past, we have routinely used the "add all instance paths" function to automatically add variables to VAR_CONFIG lists. My recollection is that compiling a project did not require VAR_CONFIG to be fully populated, and, once successfully compiled, instance paths could be added. Errors related to missing declarations, if I recall correctly, were thrown when downloading to the PLC, they did not prevent a successful compile. At some point, it stopped working. Missing declarations in a VAR_CONFIG now cause a compile error, so the application is never "current", the only reason I can see being the missing VAR_CONFIG declarations themselves (no other error). We observe the same behavior across all our projects. This is really aggravating, and I must be missing something simple. We use 3.5 SP17p3, 64 bits. Can anyone help?
Last updated: 2023-12-29
Post by jmohre on External file with relative path
CODESYS Forge
talk
(Post)
I try to add a simple text file to my PLC application, so that is download everytime the application is downloaded to the target. What I did is to add an external file to the application and this works perfect as long as the external file location does not change. It looks like the external file path is stored absolute in project. But if different users work on the project they may have different locations where for their working directory. Is there an option to store the external file path relative e.g. to the project file? Or does s.o. know a different solution to add a text file to application in order to download automatically with the application? Thanks
Last updated: 2024-01-04
Post by vformanek on irq-set piority is not working in plc-shell
CODESYS Forge
talk
(Post)
Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html But the irq-set is not changing the priority. See the image bellow....
Last updated: 2024-01-05
Post by anderson on function block output
CODESYS Forge
talk
(Post)
I'm trying to make a CNC machine, but I'm having problems because the drive I'm using only has the option of communicating through digital inputs. In this case, I should use the CLP's digital outputs to communicate with it, correct? However, in the function blocks it seems that they are already pre-programmed and I didn't find the pulse output options, for example, so that I could associate a digital output from the PLC to connect this to the drive's pulse input. My question is: is it possible to associate the pulse output of the function block with a digital output of the PLC? and how to do this?
Last updated: 2024-01-05
Post by timvh on Is it possible to use debug functions such as Step Execution while the PLC ladder is in Running?
CODESYS Forge
talk
(Post)
Yes, it is possible to set breakpoints and use step into / step over (also in Ladder diagram). Yes, the PLC will actually stop, so be carefull with this. How a PLC works is that at the start of the execution of the Task, the Inputs are read, then the code is being executed and then the outputs are written. So if you set a breakpoint, you will not see your analog inputs changing, because the task cycle is interrupted and the inputs and outputs are not refreshed. For detailed information, see: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_using_breakpoints.html
Last updated: 2024-01-16
Post by matthew on New Ladder Diagram conversion does not work due to missing features
CODESYS Forge
talk
(Post)
Hi It looks like in the new ladder there is no way to remove unused FB call parameters or update the function block? It's quite often where you have a function block with multiple uses and not all the parameters are required. Need the ability to leave an input/output blank without getting an compile error Expression expected instead of '' Also double clicking on the FB no longer opens the underlying FB code and view what it was doing online. Dragging and dropping a variable does not work, only using the selection works. Will these be available in the V1.0 release or just best to stick to the old ladder until it's available? Thanks
Last updated: 2024-01-28
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by tama00 on Datenübertragung mit SSP0 zw. uC und Raspberry Pi mit Codesys Runtime
CODESYS Forge
talk
(Post)
Hallo zusammen, ich arbeite derzeit an einem Projekt, bei dem ich einen Microcontroller habe, der Messwerte über die SSP0-Schnittstelle an einen Raspberry Pi senden soll. Diese Daten sollen dann in Codesys für eine Soll/Istwert Vergleich/Regelung verwendet werden, und das Ergebnis soll zurück an den Microcontroller geschickt werden. Meine Frage ist, ob es möglich ist, diese Kommunikation über die SSP0-Schnittstelle (als SPI frame format) zu realisieren, oder ob ich auf eine 'reine' SPI-Schnittstelle des uCs zurückzugreifen muss. Gibt es spezielle Dinge, die ich beachten muss, um diese Datenübertragung erfolgreich in Codesys zu implementieren? Ich wäre sehr dankbar für Ratschläge oder Hinweise, wie ich dieses Vorhaben am besten umsetzen kann. Vielen Dank im Voraus!
Last updated: 2024-01-31
Post by dkugler on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
the magic option is named "Use CurrentVisu variable" activate this option in the Visualization Manager an have a look: https://help.codesys.com/webapp/_visu_obj_manager;product=core_visualization;version=3.5.14.0 if your button is pressed, "feed" the string varable VisuElems.CurrentVisu := 'visu1'; with the correct name of the depending visu. alternative: place a frame element at a empty main visu, konfigure all visus to be shown by this frame. With setting the switching variable of the frame to the index value of the depending visu, it will switch to it. Advantage: the visu names are not hardcoded as string in the ladder lodgic. Good luck! Hint: If you have multiple VisuClients(Target, WebVisu,...) all will show the same visu. Independent switching is much more difficult, but there is a example from codesys.
Last updated: 2024-02-13
Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by tokamk on Dynamic setting of the modbus tcp/ip slave ip address
CODESYS Forge
talk
(Post)
Hello, I'm working on a project which includes Panel-PC which communicates with a PLC through Modbus TCP/IP. On the PLC I have a CODESYS code which has Modbus slave objects. The Modbus slave objects have to have manually set IP address in order for them to work properly and the Ip address has to be the PC-Panels's IP. This project is going to a customer and they're using their own IP address realm. So, my question is that is it possible to configure these slaves in some other way, so that the customer doesn't need to modify the CODESYS project? I was thinking that would it be possible to set the IP address of these slaves from external source?
Last updated: 2024-02-15
Post by timvh on CODESYS V3.5 SP15 Patch 2 won't open
CODESYS Forge
talk
(Post)
This is almost always related to previously working with an additonal monitor. If you have placed CODESYS on that monitor, later start your laptop again and open CODESYS without that monitor, then Windows still places it in the previous position, but then it is not visible. So the solution by cehermanstad can be used to move it to the main screen to make it visible again. PS, another way to move it, is by pressing SHIFT and then right-click on the icon in the task bar, then select move. You can then move it with the arrow keys or your mouse.
Last updated: 2024-02-27
Post by nilesh on Request for Assistance with Online Logic Changes in PLC System using Codesys
CODESYS Forge
talk
(Post)
Dear Sir, We are writing to seek guidance regarding our current situation with the Opto 22 Groov EPIC PR1 PLC system. Over the past year, we have successfully downloaded and implemented logic using Codesys, and the PLC has been operational without issues. However, we now require minor modifications to the logic. Despite attempting to upload the modified logic, we are unable to see the "online change" option, prompting us to consider a direct logic download. Our concern is that during this process, certain digital outputs or analog outputs might momentarily disrupt operations, which is unacceptable given the system's continuous 24x7 operation. We have explored online changes in other PLC systems, but due to the absence of the last downloaded backup, we are unable to proceed confidently.
Last updated: 2024-03-01
Post by mp9876 on Problems with simulation in Window 10
CODESYS Forge
talk
(Post)
Hi Automa, it seems the solution you were bringing up on 2022-04-06 could really help me as I did not remember the password I initially set. My problem though is that I am using Codesys Control Win V3.5 SP19/60 (64 bit) and I cannot locate any of the files you listed up there. I have been looking inside folder: C:\Program Files\CODESYS 3.5.19.60\CODESYS\ and they appear not to be present at all neither in the CODESYS folder or any sub-folders. Uninstalling and re-installing unfortunately does not do the trick. Any idea how I could get out of the ditch on this issue ? Anyone else maybe ? Thanks
Last updated: 2024-03-18
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
If support for a containerized CODESYS runtime with a license isn't feasible, then I've considered an alternative approach: I've purchased and activated a "CODESYS Control Basic S" license on my Windows notebook, where I already have the Codemeter Control Center installed. Upon activation, I can see the CODESYS license as active on my notebook. Subsequently, I followed the instructions provided in this link (https://faq.codesys.com/display/CDSFAQ/How+to%3A+Setup+a+Wibu+Network+Server+Access+for+Licenses) to configure the Wibu runtime in the CODESYS container to access my external license server hosted on my notebook by editing the CODESYSControl_User.cfg file accordingly. However, it's worth noting that I'm still receiving a response from the Licensing Manager indicating that the runtime is persistently searching for a dongle instead of recognizing the soft container. So how can I get my runtime licensed now? Any ideas?
Last updated: 2024-03-20
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.