Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Hello, I have a problem when opening the license manager for my raspberry pi (CM4 model) with runtime 4.13.0.0. I select "Device" --> "Soft Container" and click on my device in the scan window but I get this error message : Licensing info not available. There is no dongle attached to this device. I can't install licenses anymore, and I don't understand why is CodeSys looking for a dongle when I specified I wanted to use a Soft Container. Can somebody help me please ? Best regards
Last updated: 2024-10-04
Post by bzzz on Connect WS2812B Light Strip to CodeSys via RasPi
CODESYS Forge
talk
(Post)
Hey guys, I have a RasPi and can control my WS2812B (addressable light strip) via Python. The lightstrip is this one: https://core-electronics.com.au/1m-rgb-led-strip-ws2812b-144-per-meter-white-strip-weatherproof.html What I would like to do is to control it directly via CodeSys through the plc on my RasPi. I know I can run a python script on CodeSys, but I'd like to avoid doing that. Is it possible, and how do I do it? Is there a library that does this?
Last updated: 2024-10-16
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Finnaly i get it working. There was a line in the file that set the ADS1015 chip in /boot/firmware/config.txt which i removed and after that the ADS1115 has a green turning circle and i got values. i created a new component so it fits our ADS1015. see screenshot. It works also with Codesys Control for Raspberry Pi 64 SL after adding the ULINT_TO_UDINT conversion in the library. i think the chip was all the time in use by the Raspberry pi itself. Thanks for your help!
Last updated: 2024-11-12
Post by dsa28 on EL6910 as a PROFIsafe F-Host in Codesys
CODESYS Forge
talk
(Post)
Hello All, Does anyone have experience configuring a PROFIsafe communication between EL6910 (F-Host) and and a F-Device in Codesys? I would expect that the PROFIsafe configuration process would be pretty similar as the FSoE configuration. Although, when an F-Device is included under PN-Controller, Codesys doesn't allocate a PROFIsafe logical device automatically under EL6910, as it happens when a FSoE slave is added under EtherCAT master. I thank anyone in advance who can help me on this.
Last updated: 2024-12-05
Post by aliazzz on Runtime licenses not detected => DEMO Mode 2hour
CODESYS Forge
talk
(Post)
Hi! After upgrading all my licensed runtimes to V4.14.0.0 (= RaspberryPi SL, LinuxSL and ControlWin x64 SL) I found out via the logfiles they all defaulted back into DEMO mode while all runtimes have a USB dongle inserted. So, my main question is how I can get the Dongle license detected? I use License Server 4.14.0.0 and Edge Gateway 4.14.0.0 on all platforms Any suggestions are welcome.
Last updated: 2024-12-15
Post by aliazzz on Raspberry Pi 3: Linux/ARMHFv7 unknown container technology
CODESYS Forge
talk
(Post)
Hi CODESYS team! It seems Podman for Raspberry Pi 3 is not detected correctly in the latest "Deploy Control SL 4.14.0.0" : Linux/ARMHFv7 unknown container technology. 1) The Communication Tab, device information section shows podman technology as DETECTED. 2) The Runtime Deployment menu message says: "unknown container architecture" 3) The pulldown window under the deployment tab doesn't show the options for ARMHF Virtual Edge SL and ARMHF Virtual Control SL. I hope you can fix this soon and keep up the great work!
Last updated: 2024-12-15
Post by dagi89 on CAA File open Problems
CODESYS Forge
talk
(Post)
Dear All, i am using Runtime CODESYS Control Win V3 - X64 Version 3.5.20.40, by using CAA file library (3.5.19.0) seems not fasible to open a file n 'C:\ciao.txt' or others absolute path. The error on File Open is 5114 File Operation Danied.. here below the implemented code and the windows file's properties. I use to implement codesys in RPI and this operation is immediate... Can someone help me in it?? Thanks in advance Dagi89
Last updated: 2024-12-21
Post by askic on PLC error log help
CODESYS Forge
talk
(Post)
Hello, I'm using Codesys 3.5.20.0 version and I noticed that even with the most basic standard project create, there are error messages like shown in the acttached picture. The similar questions are already asked here on the CODESYS Forge Talk, but remained unanswered. Exact screenshot is attached, but essentially I would like to know which component in the Codesys has CmpID = 0x00000019 and what this Timeout means?
Last updated: 2025-01-10
Post by askic on Disable/Enable Supervision
CODESYS Forge
talk
(Post)
Hello, I have found the following instruction in the online help( https://content.helpme-codesys.com/en/libs/CmpSupervisor/3.5.17.0/SupervisorOperationSetTimeout.html ): Sets a (new) timeout for the given operation Supervision must be disabled to modify the timeout and should be enabled afterwards. However, I don't quite understand how to do this? Where can I disable and later enable Supervision? Is it through Codesys application or device menu? I don't find instructions clear.
Last updated: 2025-01-16
Post by andre-luis on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
Hi @TimvH, In the meantime, I did some experiments and could find a way to achieve similar result. I made some tests, removing the last card from the array, seeing the change on status. PROGRAM P_IOS_STATUSES VAR devStateInput : DEVICE_STATE; devStateOutput : DEVICE_STATE; devStateEncoder : DEVICE_STATE; END_VAR devStateInput := IoConfig_Globals.EL1819.GetDeviceState(); devStateOutput := IoConfig_Globals.EL2809.GetDeviceState(); devStateEncoder := IoConfig_Globals.EL5151.GetDeviceState(); GVL.bInputCardOK := ( devStateInput = DEVICE_STATE.RUNNING ); GVL.bOutputCardOK := ( devStateOutput = DEVICE_STATE.RUNNING ); GVL.bEncoderCardOK := ( devStateEncoder = DEVICE_STATE.RUNNING ); Many thanks for your quick and extensive reply.
Last updated: 2025-02-06
Post by rmaas on TCP Server
CODESYS Forge
talk
(Post)
Hi George, I do not know what the problem is with the syssocket implementation, but when i read the forums it seems the Net Base Services library is the recommended way to go. There is another more extensive example here: https://forge.codesys.com/prj/codesys-example/plc-chat-nbs/home/Home/ I have just tested this example and it works very well, also with closing and opening the connection from hercules... good luck!
Last updated: 2025-02-20
Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess)
CODESYS Forge
talk
(Post)
Wow! Thanks mr Strucc. Changed to service to run as local acc, and now log works! The service (run from local acc) is using this config: C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg The path you first mentioned (c:\Windows\System32\config\systemprofile\AppData\Roaming) has no CODESYS folder in it (Windows 11 24H2 b26100.3194). Thanks for your help :)
Last updated: 2025-03-06
Post by trusty-squire on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Not sure if you've resolved this yet, but the Codesys runtime user/password is different than the Linux user/password. You'll need the Linux user credentials when you log in over SSH (for example, to install the Codesys runtime). When you first log in to Codesys on the RaspPi you'll set up a Codesys user and password. If you lost those credentials, you could try uninstalling and then re-installing the Codesys runtime on the RaspPi so you can setup a new user/password.
Last updated: 2025-03-16
Post by krisj on ScriptEngine POU property Get and Set accessor.
CODESYS Forge
talk
(Post)
Hey! I am trying to generate a function block with properties from a list with script engine. Codesys/ScriptEngine creates both the Get and the Set accessor. I cannot find a way to delete the Set method/accessor. Anyone encountered the same problem or have a solution for this? for prop_name, prop_type in list: property = pou.create_property(prop_name, prop_type) get = pou.find("Get", recursive=True)[i] get.textual_declaration.replace("") get.textual_implementation.replace(prop_name + " := " + struct_name + "." + prop_name + ";") set = pou.find("Set", recursive=True)[i] set.textual_declaration.replace("") set.textual_implementation.replace("") i += 1
Last updated: 2025-03-17
Post by imdatatas on Import from XML problem
CODESYS Forge
talk
(Post)
Hello Everyone, When I try to import some POUs that were previously exported from another project as an XML file, I get an error like in attached image and the process does not complete. "There are no objects in the export file..." I am using SP21 Codesys IDE and I do not know which version this XML (*.export) file was previously exported with. Has anyone encountered the same problem? Regards, imdatatas
Last updated: 2025-04-26
Post by marks on Siemens G120X via Ethernet/IP
CODESYS Forge
talk
(Post)
The goal is to control a Siemens G120X VFD via Ethernet/IP. The .eds is installed into the device repository. The VFD is added and is using the connection and assemblies from the eds. It appears to reach the VFD but fails to establish a connection. The status message is: Diag String: 'Adapter configured. Open all connections.' The PLC is a raspberry pi 4, running codesys target version 4.13.0.0. The development environment is CODESYS V3.5 SP21 + (64-bit). Anyone have experience with this combination? Alternately, where should I look next? Thank you, Mark
Last updated: 2025-05-06
Post by glutenaron on Safety drive EL6900 and mitsubishi
CODESYS Forge
talk
(Post)
Hi, Im wokring to get my servo mitsubishi mr-j5-g40-rnj1 working with my safety drive. I have as you can se in the picture Ek1100 koppler and EL6900 as safety plc. My questien is how do i connect the safety_drive to the SM3_Drive_ETC_Mitsubishi_MelServo_J5_Axis1 down below? I get the error ((Logical I/Os]: The logical device 'Safety_Drive' is not mapped to any physical device.)) but how do i map this? regard
Last updated: 2025-05-13
Post by hickan on safety cpu cannot go online
CODESYS Forge
talk
(Post)
Hi! I am using abb ac500 in automation builder v2.7 I have a problem with a new project. In the normal mode I have no problems, but in safety mode i cannot go online. I get 'Communication Error (#0) Logout Performed' message. I have tried changing the adress (level 1) in communication parameters. I tried 0.0.0.0.0 and 0.1.0.0.0 and 1.1.0.0.0 but it did no difference. What do you think could be causing this? Thanks!
Last updated: 2025-07-08
Post by camjam on BOOL variable in OPC UA and modbus simultaneously
CODESYS Forge
talk
(Post)
I have come across this. The only way i could get it to work would be to define a word that is also the same address as the Bools. eg %MX600.0 through to %MX600.15 would be individually defined in the variables and them have another variable word defined at %MW300. You still need to break out the word in what ever program you are using to read/write the OPCUA tags.
Last updated: 2025-08-18
Post by nha451 on EIP Scanner not receiving data from adapter
CODESYS Forge
talk
(Post)
Hello, I have an EtherNet IP adapter (GoPxL) running with a virtual PLC. I have successfully connected the adapter with green icons next to it. On WireShark I can see the data coming from GoPxL but on CODESYS it shows up as all 0. My firewall is turned off and I have enabled the device to always update variables. I tested my set up with Profinet and I can receive the data. Please let me know if you have any suggestions!
Last updated: 2025-09-12
Post by wedahitha on Could not open library 'SysSocket23,
CODESYS Forge
talk
(Post)
Hi there, I am trying to open a codesys project done by someone else and Once I install all the libraries I get this error [ERROR] : Library Manager [PROJECT 01: PLC Logic: Application]: Could not open library 'SysSocket23, * (System)'. (Reason: The library 'SysSocket23, * (System)' has not been installed to the system.) SysSocket23 is a standard library and I also tried using the same OSCAT library which was from the original computer that made this code. Using CODESYS V3.5 SP18 Patch 2 Please help me how to solve this problem.
Last updated: 2023-12-19
Post by wiresplus on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26
Post by suthesan on Error when I go online on Simulation or PLC
CODESYS Forge
talk
(Post)
Hello I not sure if I made this topic under the right category. But I have a error, when I try to run a simple code on simulation or PLC. I have also tried to make a fresh project. I am testing the PLC and want to see if there is some way I can make an actuator run. Please help by looking at the picture, Iam stuckd and I don't know how to fix it.
Last updated: 2024-02-07
Post by goki on WAGO RS485 (753-652) on a 750-362
CODESYS Forge
talk
(Post)
hi guys Maybe someone can help me in this case. Im working with codesys 3.5 with an PFC200 (750-8212) with a Modbus TCP conection to the 750-362. On the 750-362 i have a 4DO, 8DI and a RS485 interface card. the 4DO and 8DI cards a working fine but im strugling with the rs485 card. Does someone have a example for this?
Last updated: 2024-02-08
Post by k4zz on Scripting static code analysis
CODESYS Forge
talk
(Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.