Post by julianramirez on Visu 4.9.1 auto-logon/login
CODESYS Forge
talk
(Post)
Hello everyone, I have been trying to test the auto-login feature that is advertised on the Release Notes since Visu 4.8: *Version: 4.8.0.0 Besides some bug fixes and improvements this version contains the following new functionality: Alarmmanagement: Possibility to raise alarms programmatically Use real time clock of IEC context Automatic login for WebVisu using Chrome "Sign in automatically"* I am using a personalized login Visualization, the User Management works, however, when ticking the checkbox that keeps the credentials stored, after I reload the page I still see that the user and password details are not filled in. I tried with the default Login Visu (Blue one), and still see the same behavior - VisuUserManagement.VUM_LoginVisualization - I've tried with Chrome and Edge. Thanks for your help
Last updated: 2026-01-12
Post by sheberle on No Bootproject possible
CODESYS Forge
talk
(Post)
Hello Alex, the message is generated by the CODESYS code generator based on the DevDesc settings of the memory areas available for the target. The problem arises when after too many online changes the area is full. Therefore no more boot project can be generated. Short-term remedy as described in the dialog: Clean and fresh download. This way the initial memory size will be "used" again After how many online changes did this error occur? There is no set limit on the number of online changes, but making too many changes could be a risk. br Simon
Last updated: 2026-03-31
Post by wistaro on Hardware compatibility with Linux RealTime PLC
CODESYS Forge
talk
(Post)
Hello, I am currently using Codesys Control RTE Softmotion V3 to control my servo-drives in CAN, EtherCAT and PROFINET IRT. I am using a PC with Windows 10 with the following boards: - PEAK-CAN PCIe board (for CAN and Softmotion); - Hilscher CifX with firmware 3.X and SysDrv3s driver (for PROFINET IRT); - Realteak standard NIC (for EtherCAT). I would like to switch to Linux (Debian), because this computer is old, slow, and outdated (Windows 11 is far from being compatible with this computer). Before doing this, I would like to be sure of the compatility between my 3 boards and Codesys Control Linux SL. Otherwize, I will stay on Windows 10 and use it in an isolated environnement. Thanks for your advices. Regards,
Last updated: 4 days ago
Post by konstantin on Lenze i950 Servo and WAGO PFC200
CODESYS Forge
talk
(Post)
Hello, basically the i950 drive support CiA402 Basic and CiA402 Advanced modes. I attached pictures of both mode supported functions. It also support CSP, VL, CSV and CST modes. It seems the homing mode is in CiA402 Advanced mode but how can you not have the homing mode in both modes? It is a vital part of any servo system. If I use the SoftMotion standard demo mode, I can move the servo absolute and relative but cannot home it. But in SoftMotion Light mode, I cannot execute any motion function. Here is the official manual for i950 servo drive - i950 Documentation Best Regards Konstantin Kolev
Last updated: 2026-02-13
Post by gseidel on Absolute movement controlled by an external encoder.
CODESYS Forge
talk
(Post)
Hi polyautomacao, basically, there are two ways to approach this. My first choice would be to check whether your servo drives supports an external encoder, connect the encoder to the servo and configure the servo accordingly. In this case, you would not need to change anything in the CODESYS application. If that is not an option, you could use SM_DrivePosControl, a drive that closes the position loop in the PLC, and feed it with the external encoder positions. See (0). You can switch your servo drive to velocity control mode (SMC_SetControllerMode) and use SMC_FollowVelocity to apply the fSetVelocity of the SM_DrivePosControl to your servo. The MC_MoveAbsolute can then be performed on the SC_DrivePosControl Hope that helps. (0) https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_example_poscontrol.html Best regards, Georg
Last updated: 2026-03-04
Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error
CODESYS Forge
talk
(Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22
Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error
CODESYS Forge
talk
(Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22
Post by alexgooi on Network variable stops sending
CODESYS Forge
talk
(Post)
Hi Reinier, What usually works for me is settings it up in the following way: In the sender block make sure that the list identifier is unique for the whole installation (this is only relevant when you have multiple senders in 1 network). When you are linking the NVL to a file make sure that the path to this file doesn't change. In my experience the NVL stops working when you change the working directory and afterwards open the NVL in de Codesys IDE. If this doesn’t apply to you application, you could also try to change the port number, maybe there is an other process making use of port 1202. Kind regards Alex
Last updated: 2026-04-22
Post by timvh on library inside library
CODESYS Forge
talk
(Post)
1) it should be possible to access the type SysTime in the project as A_Lib.SysTime. 2) you could add the SysTimeCore library to the library manager of your library (POU Pool). This might seem as a double library, but because of the placeholder resolution only one will be used. Then, in your library manager of your library, select the SysTimeCore library, right-click, select "Properties" and enable the option "Publish all IEC symbols ...." For more information about library development, you could follow our advanced training course in Ridderkerk. The next is scheduled for 24 and 25 June 2026 https://www.extendsmartcoding.nl/codesys-training/
Last updated: 2026-04-25
Post by kurt9 on ReadWriteEEprom FB question
CODESYS Forge
talk
(Post)
I want to programmatically write the alias address to a new EtherCAT slave when I plug it into my IPC EtherCAT network. I am looking at the ReadWriteEEprom FB and see that one of the elements is "pbyData". which is the pointer to byte that is usually set to 2048 bytes. Since I am setting the alias address to the EEprom only (EEprom address 16#0012), I would assume that what I am writing is 2 bytes only. Does the pbyData have to be specified as ADR(myArray) where "myArray" is the 2 bytes of the alias address? How is the best way to set this element of the function block? Thanks in advance
Last updated: 2026-05-18
Post by jroddball79 on PM556-TP-ETH — How to change IP address without overwriting the PLC program?
CODESYS Forge
talk
(Post)
We have checked open ports. SSH (22) and HTTP (80) are not reachable. The only open ports are: 502 (Modbus TCP — used for lighting control) 1200 (CODESYS runtime) 1201 (CODESYS runtime) We can connect via Automation Builder using the current IP, but we don't have the original project source — only an empty project. This is why we are afraid of doing a full download, as it would overwrite the running application. Is there any way to change the IP through the CODESYS runtime protocol on ports 1200/1201 without affecting the running program?"
Last updated: 2026-05-20
Post by brouwyka on JSONByteArrayWriter problem?
CODESYS Forge
talk
(Post)
Hey there! I am currently running into the exact same issue. The JsonData object has all inexes & parent indexes in the way I expect, everything is correctly "linked". It purely seems that the writer is incorrectly parsing said JsonData, not based on parent & child index, but on something else that breaks it and puts things at the root, instead of the specified parent index. Did you ever manage to find a solution, or another way of achieving your JSON composing? I'm currently working on Codesys V3.5 SP19 Patch 7 with IIOT Libraries SL 1.13.0.0, specifically JSON Utilities SL 1.13.0.0 (to send requests to APIs with JSON bodies using Web Client SL 1.13.0.0).
Last updated: 2026-06-08
Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4
CODESYS Forge
talk
(Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-20
Post by timo on String nach erlaubten/unerlaubten Zeichen durchsuchen
CODESYS Forge
talk
(Post)
Hallo, Ich bastele gerade an einer möglichst einfachen Möglichkeit mit der ich prüfen kann ob ein String Sonderzeichen enthält. Mein Ansatz ist ein ST FB mit einer Case Schrittkette. Ich vergleiche jedes Zeichen des Strings mit allen Zeichen eines vorher definierten Strings erlaubter Zeichen, der A-Z, a-z und 0-9 enthält und ggf angepasst werden kann, wenn ich weitere Zeichen erlaube. Leider wird meine j Zählervariable nicht richtig ausgeführt. Hat da jemand eine Idee? Oder gibt es eine einfachere Lösung/einen fertigen FB den ich mir anschauen kann? FUNCTION_BLOCK Sonderzeichen_Check VAR_INPUT inputString : STRING; // Zu prüfender String startCheck : BOOL; // Startsignal END_VAR VAR_OUTPUT ok : BOOL; // TRUE, wenn keine ungültigen Zeichen END_VAR VAR i : INT := 1; // Input-String Zähler j : INT := 1; // erlaubte Zeichen Zähler allowedChars: STRING := 'ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789'; // Erlaubte Zeichen currentChar : STRING[1]; // Aktuelles Zeichen step : INT := 0; // Schritt END_VAR CASE step OF 0: // Warten auf Start IF startCheck THEN step := 10; END_IF 10: // Initialisierungen i := 1; j := 1; ok := TRUE; // Standard: ok step := 20; 20: // Durchgehen des Eingangs-Strings IF i <= LEN(inputString) THEN currentChar := MID(inputString, i, 1); // Aktuelles Zeichen step := 30; ELSE step := 70; // Alle Zeichen ok END_IF 30: // Durchgehen der erlaubten Zeichen IF j <= LEN(allowedChars) THEN step := 40; // Zu Schritt 40 ELSE step := 60; // Ungültiges Zeichen END_IF 40: // Vergleich IF currentChar = MID(allowedChars, j, 1) THEN i := i + 1; // Nächstes Zeichen im Input step := 20; ELSE j := j + 1; // Nächstes erlaubtes Zeichen step := 30; END_IF 60: // Ungültiges Zeichen ok := FALSE; // Setze auf FALSE step := 0; 70: // Alle Zeichen ok step := 0; END_CASE
Last updated: 2025-01-20
Post by otbeka on CAA File Handling: "Read only" error
CODESYS Forge
talk
(Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
Thank you very much for the quick answer! The RPi hw were delivered last week so it's probably a resent version. I found an old scrapped board (2 years or so) with a broken GPIO that I tested with the same SD card image and with that board Codeys can run for the full 2h demo period without issues. Then I went back the the new board to test the 4.17.0.0 release but the installation fails... [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol Do you have any idea what could be the reason? I'm using an OS image including Python drivers for LCD and some I/O:s from last year to keep things stable, but also after upgrading with sudo apt update && sudo apt upgrade I still get the same error Reverting back to 4.15.00 works fine: [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesysedge started [INFORMATION] Successfully installed codesyscontrol [INFORMATION] Successfully started CODESYS Edge Gateway for Linux [INFORMATION] Successfully started CODESYS Control for Raspberry Pi SL but as before the Codesys services stops after 30 seconds. And I noticed that the Codesys control stops and is not reachable also if I have no application loaded.
Last updated: 2025-09-02
Post by anonymous on Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Post)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part.I am able to capture the data of client side in wireshark but i am unable to capture it in the codesys. Heres the below part of code of client side. PROGRAM POU_udpclient_program VAR istep : INT := 1;//step variable for state machine xStart: BOOL;// Flag to start the UDP protocol iecSocketId: syssocket_interfaces.RTS_IEC_HANDLE;//socket handle for receiving iecCreateResult: syssocket_interfaces.RTS_IEC_RESULT; ipAddr: syssocket.SOCKADDRESS;//Socket address structure for receiving sIpAddress : STRING := '192.168.0.2'; wPort: WORD:= 12346; iecConnectResult : syssocket_interfaces.RTS_IEC_RESULT;//connect paramters sDataRec : STRING[255];//Buffer for received data xiRecBytes : __XINT;//number of bytes received iecRecResult : syssocket_interfaces.RTS_IEC_RESULT;//receive data parameters iecCloseResult : syssocket_interfaces.RTS_IEC_RESULT; END_VAR syssocket.SysSockInetAddr(sIpAddress,ADR(ipAddr.sin_addr)); ipAddr.sin_family := syssocket.SOCKET_AF_INET; ipAddr.sin_port := syssocket.SysSockHtons(wPort); CASE istep OF 1: //create socket IF xStart THEN iecSocketId:= syssocket.SysSockCreate(syssocket.SOCKET_AF_INET,syssocket.SOCKET_DGRAM,syssocket.SOCKET_IPPROTO_IP,ADR(iecCreateResult)); IF iecSocketId = syssocket_interfaces.RTS_INVALID_HANDLE THEN xStart := FALSE; istep := 1; ELSE istep := 2; END_IF END_IF 2: //connect to socket server using setoption iecConnectResult := syssocket.SysSockSetOption(iecSocketId,syssocket.SOCKET_SOL,syssocket.SOCKET_SO_REUSEADDR,ADR(ipAddr),SIZEOF(ipAddr)); istep := 3; 3: //receive data xiRecBytes := syssocket.SysSockRecvFrom(iecSocketId,ADR(sDataRec),SIZEOF(sDataRec),0,ADR(ipAddr),SIZEOF(ipAddr),ADR(iecRecResult)); istep := 4; 4: //close socket iecCloseResult:= syssocket.SysSockClose(iecSocketId); xStart := FALSE; istep := 1; END_CASE
Last updated: 2024-06-03
Post by alessandro on SysMemCmp SysMemCpy
CODESYS Forge
talk
(Post)
VAR Data1:ARRAY[1..10] OF SINT ; Data2:ARRAY[1..10] OF SINT ; Data3:ARRAY[1..10] OF SINT ; Data4:ARRAY[1..10] OF SINT ; ex_1 : BOOL ; ex_2 : BOOL ; enable : BOOL :=0 ; END_VAR // PROGRAM // The scope of this example is compare and copy the values of two ARRAY only if some value is different using SysMemCmp and SysMemCpy. // In this 2 example we don't use a FOR cicle for do this, and pBuffer1 and pBuffer2 is just a pointer to ARRAY. See details in Library util.SysMem of Codesys // The compare funcion util.SysMem.SysMemCmp is bidirectional if Data1 chanege respect Data2 ex_1 go to 1 and if Data2 change respect Data1 also // but the copy function util.SysMem.SysMemCpy work only from source ARRAY pSrc:=ADR(Data1) to destination ARRAY pDest:=ADR(Data2) // Example 1 Full ARRAY compare and copy // This compare 2 different equal ARRAY and if there is some difference ex_1 go to 1 and if you give enable he copy Data1 in Data2 ex_1 := TO_BOOL(util.SysMem.SysMemCmp(pBuffer1:=ADR(Data1), pBuffer2:=ADR(Data2), udiCount:=SIZEOF(Data1))); IF ex_1 AND enable THEN util.SysMem.SysMemCpy(pDest:=ADR(Data2), pSrc:=ADR(Data1), udiCount:=SIZEOF(Data1)); END_IF // Example 2 Only selected area of the ARRAY compare and copy // This compare 2 different equal ARRAY starting from position number [3] for 4 byte in this case start at position [3] and finish at position number [6] // and if there is some difference only in area [3..6] of the ARRAY ex_2 go to 1 if you give enalbe he copy Data3[3..6] in Data4[3..6] // if something change in other array position[0..2] or [7..10] are ingnored ex_2 := TO_BOOL(util.SysMem.SysMemCmp(pBuffer1:=ADR(Data3[3]), pBuffer2:=ADR(Data4[3]), udiCount:=4)); IF ex_2 AND enable THEN util.SysMem.SysMemCpy(pDest:=ADR(Data4[3]), pSrc:=ADR(Data3[3]), udiCount:=4); END_IF // Attention udiCount input is intended in <byte> in the example 1 I pass to udiCount:=SIZEOF(Data1) for compare and copy the intere ARRAY and // SIZEOF pass the size of intere ARRAY in byte to the function input, in this 2 examples I used variable type SINT each one occupie 1 byte and one position in the ARRAY // and in the example 2 I pass udiCount:=4 for compare and copy only 4 position of Data3/4[3..6] if you want to extend this example and use it for an ARRAY OF WORD // remember that each WORD will occupe 2 byte (16 bit) and you will have to pass udiCount:=SIZEOF(Data1) if you need to compare intere ARRAY example 1 // but need udiCount:=(42) for the example 2 because need to compare and copy 4 word each occupie 2 byte (16 bit). // For REAL (32 bit) need udiCount:=SIZEOF(44) for LREAL or (64 bit) need udiCount:=SIZEOF(416) // a good rule is calculate the dimension of the ARRAY in byte without empty space at the end, multiple of data type number for variable bigger then 8 bit // Example : If you want to create an ARRAY for 5 REAL (32 bit) each occupie 4 byte the correct size is ARRAY[0..19] OF REAL 54=20 position. // NOTE : In the example the position of compare function util.SysMem.SysMemCmp is first and the copy function util.SysMem.SysMemCpy inside the IF is after // in one cycle of the program the two array is compared and if there is some difference and enable are copied. // If you move util.SysMem.SysMemCmp after the IF cycle he will copare the ARRAY in the current cycle but the copy of the value will do in the next cycle.</byte>
Last updated: 2025-10-24
Post by clarenced on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks
CODESYS Forge
talk
(Post)
Using codesys v3.5 SP21 Patch 1. We are using Visualization to display alarms. Other then the automatically created AlarmManagerTask, there is no code written to call AlarmStorage_Prg. Any ideas why we would be seeing this error in the log? The runtime actually shutdown. Not sure if that was caused by this error or not. 2025-08-03T02:45:35.444Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T03:48:15.294Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T04:38:11.557Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * 2025-08-03T04:38:11.576Z, 0x0000010f, 8, 1, 0, #### Exception: SysSemEnter - Semaphore deadlock detected - owner thread died [tid:726740] - system may be in an inconsistent state. 2025-08-03T04:38:11.576Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-08-03T04:38:11.576Z, 0x00000001, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-08-03T04:40:12.308Z, 0x00000001, 1, 0, 35, CODESYS Control shutdown... 2025-08-03T04:40:13.436Z, 0x00000071, 1, 0, 13, Webserver stopped 2025-08-03T04:40:13.437Z, 0x00000114, 2, 1, 0, !!!! Warning: task_signalhandler_exit [MainTask] lost cycles: 14809 2025-08-03T04:40:13.497Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IecVarAccess</cmp>, <id>0x00001007</id> <ver>3.5.3.64</ver> 2025-08-03T04:40:13.506Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>AlarmMgr</cmp>, <id>0x00001012</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.513Z, 0x00000071, 2, 0, 14, !!!! Warning: Unbalanced calls to WebServerRequestRunning/WebServerReleaseRunning 2025-08-03T04:40:13.513Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IECVisualization</cmp>, <id>0x0000100c</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:50:17.708Z, 0x00000001, 1, 0, 36, CODESYS Control shutdown done
Last updated: 2025-08-04
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS)
CODESYS Forge
talk
(Post)
Thanks So Much for the reply! Were using the Weidmuller UV66-ADV-10-CAP-W The HMI is pointed to the URL which is assigned through u-OS. Basically when you log into the controller's webserver via browser you can view the installed apps. One of which is the Codesys runtime. When you click on that it takes you to the visualization. That corresponding url is what the HMI is looking for. I apologize I don't have that on hand as I'm in the office right now. I don't think I tried connecting using the port you mentioned and https in lieu of the u_OS URL. I can certainly try. Out of the box the u-OS is set for HTTP. Since we're isolated I havent changed that yet. When this has happened while logged on via chrome on my laptop, simply refreshing brings the visualization right back. In the case of the HMI in kiosk mode, we power cycle the HMI to force a reconnect, log back in u-OS and the visualization is back.
Last updated: 2023-09-06
Post by danwoodlock on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
Hello all, First post. I recently acquired an RPI zero W from amazon, and have been using it with Codesys v3.5 SP19 patch 2. I first got it working yesterday, and after installing the runtime on the Pi, I was prompted to install the edge gateway. Installation of the edge gateway failed because of unsupported architecture, undeterred I was able to connect to the pi and program as I wanted. The issue I've noticed is that if I do not load anything to the pi overnight, I can then no longer connect to the pi and download, although I can still ping it from my pc. I found that if I power cycle the PI, I am then able to connect again, and it works as normal. I did some googling and found instances where people recommended downloading the newest edge gateway, which brings me here. Wondering if there are any suggestions, or if this is a known issue. I actually tried installing all 3 versions of edge gateway for science, but all fail with the same message. Thanks -Dan
Last updated: 2023-09-13
Post by manuknecht on Persistence Manager does not save alphabetically first value
CODESYS Forge
talk
(Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17
Post by riccardo on VisuElems.CurrentUserGroupId is not stable
CODESYS Forge
talk
(Post)
Goodmorning TimvH, Thanks for the reply. I don't know if your solution solve my trouble yet, I am going to see the link you sent me. In the mean time I try to explane better what I need to do. I have a turbine system that get in alarm under some condition (E.g low speed of turbine) and block the itself. When the system is stoped there is no speed turbine and the system cannot start. To give to the operetor the possibility to bypass the alarms, there is an acknoledgement alarm pushbutton. This bypass must not work for everyone but only for those client that perform the login by (User Management). Furthermore, if the user perform the (manual or automatic) logout in alarm conditions, the acknowlegment must be annulled and block the system again. To do this, I need to know if an operator is logged in the page and is working to fix the problem; otherwise the syste must autoturn off again. Now I go to study your solution, if I have explaned better and you have another idea tell me please.
Last updated: 2023-11-16
Post by annd on Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2"
CODESYS Forge
talk
(Post)
Hallo, da Wago nun von eCockpit zum offenen "CODESYS Development System V3" wechselt, möchte ich meinen bestehenden 750-8212 von der PFC200 SL auf die Wago Firmware umstellen. Welche Schritte sind dabei notwendig? Den Controller würde ich auf die aktuelle FW 26 updaten und die 3.5.19.2 von Wago mit den Descriptions verwenden. Reicht es im Codesys Projektbaum mit "Gerät aktualisieren" auf den Wago Controller zu wechseln? Es wird dann statt dem "Pfc200Bus"ein leerer K-Bus und ein leerer Com-Port angezeigt. Müssen die einzelnen Module dann darunter neu angelegt und alle E/A Variablen manuell neu eingetragen werden? Das exportieren und danach wieder importieren funktioniert nicht, weil die Namen bzw. Adressen unterschiedlich sind. Ist das so richtig? Kann der Block "Modbus_COM_Port - Modbus_Master_COM_Port - Modbus_Slave" so bleiben wie bisher oder muss das auch unter dem neuen COM-Port neu angelegt werden? Für ein paar Hinweise wäre ich dankbar. Schöne Grüße, annD
Last updated: 2023-11-17
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.