Post by andre-luis on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
Hi @TimvH, In the meantime, I did some experiments and could find a way to achieve similar result. I made some tests, removing the last card from the array, seeing the change on status. PROGRAM P_IOS_STATUSES VAR devStateInput : DEVICE_STATE; devStateOutput : DEVICE_STATE; devStateEncoder : DEVICE_STATE; END_VAR devStateInput := IoConfig_Globals.EL1819.GetDeviceState(); devStateOutput := IoConfig_Globals.EL2809.GetDeviceState(); devStateEncoder := IoConfig_Globals.EL5151.GetDeviceState(); GVL.bInputCardOK := ( devStateInput = DEVICE_STATE.RUNNING ); GVL.bOutputCardOK := ( devStateOutput = DEVICE_STATE.RUNNING ); GVL.bEncoderCardOK := ( devStateEncoder = DEVICE_STATE.RUNNING ); Many thanks for your quick and extensive reply.
Last updated: 2025-02-06
Post by rmaas on TCP Server
CODESYS Forge
talk
(Post)
Hi George, I do not know what the problem is with the syssocket implementation, but when i read the forums it seems the Net Base Services library is the recommended way to go. There is another more extensive example here: https://forge.codesys.com/prj/codesys-example/plc-chat-nbs/home/Home/ I have just tested this example and it works very well, also with closing and opening the connection from hercules... good luck!
Last updated: 2025-02-20
Post by darko7417 on When running as a service, CodesysControl doesn't write log files to the disk (and other CmpLog related issuess)
CODESYS Forge
talk
(Post)
Wow! Thanks mr Strucc. Changed to service to run as local acc, and now log works! The service (run from local acc) is using this config: C:\Users\SRV\AppData\Roaming\CODESYS\CODESYSControlWinV3\C4DBB537\CODESYSControl.cfg The path you first mentioned (c:\Windows\System32\config\systemprofile\AppData\Roaming) has no CODESYS folder in it (Windows 11 24H2 b26100.3194). Thanks for your help :)
Last updated: 2025-03-06
Post by trusty-squire on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Not sure if you've resolved this yet, but the Codesys runtime user/password is different than the Linux user/password. You'll need the Linux user credentials when you log in over SSH (for example, to install the Codesys runtime). When you first log in to Codesys on the RaspPi you'll set up a Codesys user and password. If you lost those credentials, you could try uninstalling and then re-installing the Codesys runtime on the RaspPi so you can setup a new user/password.
Last updated: 2025-03-16
Post by krisj on ScriptEngine POU property Get and Set accessor.
CODESYS Forge
talk
(Post)
Hey! I am trying to generate a function block with properties from a list with script engine. Codesys/ScriptEngine creates both the Get and the Set accessor. I cannot find a way to delete the Set method/accessor. Anyone encountered the same problem or have a solution for this? for prop_name, prop_type in list: property = pou.create_property(prop_name, prop_type) get = pou.find("Get", recursive=True)[i] get.textual_declaration.replace("") get.textual_implementation.replace(prop_name + " := " + struct_name + "." + prop_name + ";") set = pou.find("Set", recursive=True)[i] set.textual_declaration.replace("") set.textual_implementation.replace("") i += 1
Last updated: 2025-03-17
Post by imdatatas on Import from XML problem
CODESYS Forge
talk
(Post)
Hello Everyone, When I try to import some POUs that were previously exported from another project as an XML file, I get an error like in attached image and the process does not complete. "There are no objects in the export file..." I am using SP21 Codesys IDE and I do not know which version this XML (*.export) file was previously exported with. Has anyone encountered the same problem? Regards, imdatatas
Last updated: 2025-04-26
Post by marks on Siemens G120X via Ethernet/IP
CODESYS Forge
talk
(Post)
The goal is to control a Siemens G120X VFD via Ethernet/IP. The .eds is installed into the device repository. The VFD is added and is using the connection and assemblies from the eds. It appears to reach the VFD but fails to establish a connection. The status message is: Diag String: 'Adapter configured. Open all connections.' The PLC is a raspberry pi 4, running codesys target version 4.13.0.0. The development environment is CODESYS V3.5 SP21 + (64-bit). Anyone have experience with this combination? Alternately, where should I look next? Thank you, Mark
Last updated: 2025-05-06
Post by glutenaron on Safety drive EL6900 and mitsubishi
CODESYS Forge
talk
(Post)
Hi, Im wokring to get my servo mitsubishi mr-j5-g40-rnj1 working with my safety drive. I have as you can se in the picture Ek1100 koppler and EL6900 as safety plc. My questien is how do i connect the safety_drive to the SM3_Drive_ETC_Mitsubishi_MelServo_J5_Axis1 down below? I get the error ((Logical I/Os]: The logical device 'Safety_Drive' is not mapped to any physical device.)) but how do i map this? regard
Last updated: 2025-05-13
Post by hickan on safety cpu cannot go online
CODESYS Forge
talk
(Post)
Hi! I am using abb ac500 in automation builder v2.7 I have a problem with a new project. In the normal mode I have no problems, but in safety mode i cannot go online. I get 'Communication Error (#0) Logout Performed' message. I have tried changing the adress (level 1) in communication parameters. I tried 0.0.0.0.0 and 0.1.0.0.0 and 1.1.0.0.0 but it did no difference. What do you think could be causing this? Thanks!
Last updated: 2025-07-08
Post by camjam on BOOL variable in OPC UA and modbus simultaneously
CODESYS Forge
talk
(Post)
I have come across this. The only way i could get it to work would be to define a word that is also the same address as the Bools. eg %MX600.0 through to %MX600.15 would be individually defined in the variables and them have another variable word defined at %MW300. You still need to break out the word in what ever program you are using to read/write the OPCUA tags.
Last updated: 2025-08-18
Post by nha451 on EIP Scanner not receiving data from adapter
CODESYS Forge
talk
(Post)
Hello, I have an EtherNet IP adapter (GoPxL) running with a virtual PLC. I have successfully connected the adapter with green icons next to it. On WireShark I can see the data coming from GoPxL but on CODESYS it shows up as all 0. My firewall is turned off and I have enabled the device to always update variables. I tested my set up with Profinet and I can receive the data. Please let me know if you have any suggestions!
Last updated: 2025-09-12
Post by wedahitha on Could not open library 'SysSocket23,
CODESYS Forge
talk
(Post)
Hi there, I am trying to open a codesys project done by someone else and Once I install all the libraries I get this error [ERROR] : Library Manager [PROJECT 01: PLC Logic: Application]: Could not open library 'SysSocket23, * (System)'. (Reason: The library 'SysSocket23, * (System)' has not been installed to the system.) SysSocket23 is a standard library and I also tried using the same OSCAT library which was from the original computer that made this code. Using CODESYS V3.5 SP18 Patch 2 Please help me how to solve this problem.
Last updated: 2023-12-19
Post by wiresplus on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26
Post by suthesan on Error when I go online on Simulation or PLC
CODESYS Forge
talk
(Post)
Hello I not sure if I made this topic under the right category. But I have a error, when I try to run a simple code on simulation or PLC. I have also tried to make a fresh project. I am testing the PLC and want to see if there is some way I can make an actuator run. Please help by looking at the picture, Iam stuckd and I don't know how to fix it.
Last updated: 2024-02-07
Post by goki on WAGO RS485 (753-652) on a 750-362
CODESYS Forge
talk
(Post)
hi guys Maybe someone can help me in this case. Im working with codesys 3.5 with an PFC200 (750-8212) with a Modbus TCP conection to the 750-362. On the 750-362 i have a 4DO, 8DI and a RS485 interface card. the 4DO and 8DI cards a working fine but im strugling with the rs485 card. Does someone have a example for this?
Last updated: 2024-02-08
Post by k4zz on Scripting static code analysis
CODESYS Forge
talk
(Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18
Post by codesysjupiter on Could not be resolved - Library error
CODESYS Forge
talk
(Post)
Hello, everyone. How are you? Please help me with my library error. When I open the CODESyS project, the error message is Could not open library “#loDrvEthernet. (Reason: The placeholder library ToDrvethemet’ could not be resolved.) I tried to find solution to fix this . and the help teach me to run this command "Update placeholder <iodrvethernet> to the newest version:" Is this right ? But I couldn't find where I input this command and how to run it. Or any other solution , please ?</iodrvethernet>
Last updated: 2024-04-12
Post by codesysjupiter on Library Error
CODESYS Forge
talk
(Post)
Hello, everyone. How are you? Please help me with my library error. When I open the CODESyS project, the error message is Could not open library “#loDrvEthernet. (Reason: The placeholder library ToDrvethemet’ could not be resolved.) I tried to find solution to fix this . and the help teach me to run this command "Update placeholder <iodrvethernet> to the newest version:" Is this right ? But I couldn't find where I input this command and how to run it. Or any other solution , please ?</iodrvethernet>
Last updated: 2024-04-12
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
I've had issues getting the raspistepper installed, all due to errors upon installation. The closest I get is the pictured error. The functions are in the sm3_shared library. I can add this library but that leaves 2 issues. I don't actually know, and I really want to understand this, why the required dependencies haven't been installed correctly. If I add the library it's only available with through the namespace. What can I do to both understand and resolve this? Thanks edit codesys 64 3.5.20.0 - same error on other versions too sm3 raspi stepper 0.0.0.5
Last updated: 2024-04-20
Post by hoatran on Use third party actuator with IO-Link Master (IFM)
CODESYS Forge
talk
(Post)
The generic sensor FB is for controlling the sensor via its cyclic input (PDI) and output (PDO). In this case, ifm raw cyclic input and output data are WORDs (16 bits total) The PDO data from the Buerkert unit are SINT (8 bits) In this case, I would use the unpackword fb from the CAA memory library to unpack the valve feed back value into the appropriate location.
Last updated: 2024-04-23
Post by alex2 on Codesys SVN
CODESYS Forge
talk
(Post)
Hello Everyone. I have a question about the SVN module on Codesys. I am using Codesys V3.5.10 and installed Codesys SVN 4.2.5.1 but when i try to connect my SVN to codesys i have a message saying that there is no license for accessing the Url. I searched on the codesys store and it seems that "CODESYS Professional Developer Edition" is needed? Am i right? Do i also need to buy a USB key? Is there another edition but only for the SVN? I thank you in advance for your answers.
Last updated: 2024-04-27
Post by shebi87 on Program from one PLC to other WAGO 750-8204
CODESYS Forge
talk
(Post)
Hello Everyone, 750-8204 was installed on a machine and it becomes faulty. We have arrange a new PLC from local market we don't have PLC program but thanks to our other machine which has the same PLC running I want to upload the program from that running PLC and download it to new PLC can anyone tell me the procedure please?
Last updated: 2024-05-21
Post by timvh on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
It seems like a bug in FBD. Work-around: If you click on the small line between the box and the output variable and delete this, the variable is removed. When you then assign a variable again (Ctrl-A), then you will see that the line will be a bit longer. If you then select the previous variable, you will see that it works.
Last updated: 2025-10-26
Post by jonasz on Deploy LicenseServer for Linux SL
CODESYS Forge
talk
(Post)
Hello, I'm asking for help with installing the license server for Linux SL 4.18.0.0. When I try to install it, I get a message that the WIBUCodeMeter package is missing. I checked the package manager tab to see if the package is installed, and it is - Codemeter 8.40.7120.501. I've checked the CodeMeter Runtime on the target machine, and everything seems to be working fine. One thing caught my eye: the Device Architecture tab says "None" Please help me solve this problem.
Last updated: 2025-11-14
Post by ppanchal on Add a dynamic text on One Visualization from another
CODESYS Forge
talk
(Post)
I've created a TitleBar Visualization in which I have "Logo" on the Left corner, "Screen Name" in the center and Time/ date on the right corner. I've also created a 'Menu" visualization that slides out from left to right. I have TitleBar and Menu Visualizations in the MainScreen (3rd Visualization). I want to have "Screen Name" automatically updated on TitleBar Visualization based on Menu item selected from the "Menu" visualization. Can anyone advise how can I achive this? TIA