Migrate from Codesys WIN 32 bit to Codesys RTE 64 bit
CODESYS Forge
talk
(Thread)
Migrate from Codesys WIN 32 bit to Codesys RTE 64 bit
Last updated: 2015-12-15
Is it possible to simulate the codesys visualizations without project file/codesys?
CODESYS Forge
talk
(Thread)
Is it possible to simulate the codesys visualizations without project file/codesys?
Last updated: 2018-10-10
Identifier ioConfigConnector not defined. CODESYS IDE V3.5SP6 corruption after installation of CODESYS IDE V3.5SP10
CODESYS Forge
talk
(Thread)
Identifier ioConfigConnector not defined. CODESYS IDE V3.5SP6 corruption after installation of CODESYS IDE V3.5SP10
Last updated: 2017-10-20
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
CODESYS Forge
talk
(Thread)
[HELP] Connecting Codesys v2.3 program with a Codesys HMI SL project in V3
Last updated: 2021-10-18
Codesys sales and support. Is it true that Codesys wants to get more customers?
CODESYS Forge
talk
(Thread)
Codesys sales and support. Is it true that Codesys wants to get more customers?
Last updated: 2023-07-03
how to convert library from CodeSys 2.3 to CodeSys 3.x ?
CODESYS Forge
talk
(Thread)
how to convert library from CodeSys 2.3 to CodeSys 3.x ?
Last updated: 2026-04-29
Post by ppix on Establishing TLS Connection with MQTT Broker using MQTT Client SL Package
CODESYS Forge
talk
(Post)
I’m currently working on establishing a TLS connection with an MQTT broker using the MQTT Client SL package in CODESYS. While I’ve successfully established communication with the broker without TLS, I'm encountering issues when trying to enable TLS. In the 'MQTT Explorer' application, I can easily upload the server certificate (.crt), client certificate (.crt), and client key (.key). However, in CODESYS, I can’t find a way to upload my client key (.key file). Here's a summary of my current setup: Certificates: I have uploaded both the client and server certificates to the certificate store under the 'Trusted Certificates' folder in the security screen. TLS Context Initialization: Despite setting the _sCommonName as the name of my client certificate, a new self-signed certificate is created and placed within the device’s certificates. I then need to manually move this certificate to the trusted certificates folder. This results in three certificates in my trusted certs folder: client cert, server cert, and the newly created cert. _ciDefaultCertInfo : MQTT.NBS.CERT_INFO := (psInfo := ADR(_sCommonName), udiSize := TO_UDINT(LEN(_sCommonName))); // CN of the certificate (common name) _sCipherList : MQTT.NBS.CIPHER_LIST := STRUCT(psList := ADR('HIGH'), udiSize := 4); // Cipher string see https://www.openssl.org/docs/man1.1.1/man1/ciphers.html _tlsContext : MQTT.NBS.TLSContext := ( sUseCaseName := _sCommonName, // A certificate is stored in the certificate store with the use case name. You can choose any name. Here we use the common name. ePurpose := MQTT.NBS.PURPOSE.CLIENT_SIDE, // For client certificates set this to NBS.PURPOSE.CLIENT_SIDE sTLSVersion := '1.3', // The TLS version sCipherList := _sCipherList, // Set the cipher list sHostname := sHostname, // The hostname of the broker udiVerificationMode := 2, // 2 => Active Peer verification ciCertInfo := _ciDefaultCertInfo, // Set the cert info itfCertVerifer := 0); // 0 => No Verifier mqttClient : MQTT.MQTTClient := (xUseTLS:=TRUE, itfTLSContext := _tlsContext, itfAsyncProperty := _asyncProperty); Additional Details: In the client FB, I’ve set uiPort:= 8883, xUseTLS:= TRUE, and configured itfTLSContext as mentioned above. The certificates are encrypted with SHA256RSA. sHostname is the IP address of my broker. I’ve attached a copy of the client FB, which shows straight lines where variables are assigned and boxes where they are not. I am currently trying this on the only 2 compatible versions of COSDESYS with my controller (V3.5.15.20 and V3.5.18.40) My Question: How do I correctly set up this mTLS connection? What might I be missing? Any guidance or suggestions would be greatly appreciated, especially considering I’ve already successfully established a non-TLS connection with the same broker. Thank you in advance for your help!
Last updated: 2024-06-19
Post by rossanoparis on CAN TX regression in Control for Raspberry Pi 4.21.0.0 with CAN API library (RX works, TX silently fails)
CODESYS Forge
talk
(Post)
Environment: Target: Revolution Pi (Kunbus RevPi), armv7l 32-bit OS: Raspbian GNU/Linux 9 (Stretch), kernel 4.19.95-rt38-v7 (SMP PREEMPT RT, built 2022-03-22) CAN: via SocketCAN (can0) Runtime: CODESYS Control for Raspberry Pi SL IDE: CODESYS V3.5 SP22 + patch 3 (previously V3.5 SP22 + patch 2, where everything worked with runtime 4.18.0.0) Library: CANBusAPI from the "CAN API" package, version 1.0.0.3 Summary: The setup worked correctly with V3.5 SP22 + patch 2 and runtime 4.18.0.0. After updating the IDE to SP22 + patch 3 and the runtime to 4.21.0.0, CAN transmission via the CANBusAPI library stopped working. Reception is unaffected. There are no error indications anywhere: the application runs normally and the CAN diagnosis reports a healthy bus. Systematic testing (below) shows the problem follows the runtime version, not the IDE update. Regression isolation: The same application (compiled under SP22 + patch 3, unchanged between tests) was downloaded to the same target with different runtime versions, changing only the runtime each time: 4.18.0.0: TX and RX both work 4.19.0.0: TX and RX both work 4.20.0.0: TX and RX both work 4.21.0.0: RX works, TX does not The behavior is fully reproducible in both directions (downgrading to 4.20 restores TX, upgrading to 4.21 breaks it again). Hardware, wiring, OS, project, and application code are identical across all tests. Diagnostic data (CANBusDiagnosis FB, while the application is transmitting on 4.21): ctSendCounter: incrementing normally ctTxErrorCounter: 0 ctRxErrorCounter: 0 eState: ERROR_FREE xBusAlarm: FALSE So the library accepts and counts the outgoing messages, no TX errors are reported, and the CAN controller state stays error-free, but the messages never reach the other nodes on the bus. Expected behavior: Messages sent via CANBusAPI (CANDriver / SendMessage) are transmitted on the bus, as with runtime versions up to and including 4.20.0.0. Notes: I am aware that the CAN API package (1.0.0.3, from 2016) is old; however, the regression is tied to the runtime version, since the identical binary works on 4.18-4.20. Questions: Is there a known change in CmpSocketCanDrv / CmpCAACanL2 between 4.20.0.0 and 4.21.0.0 that could affect TX via the CAN API library? Is runtime 4.21.0.0 still supported on Debian 9 Stretch (kernel 4.19, RT-patched), or is a newer OS required? If a minimum OS/kernel requirement was introduced with 4.21, is it documented?
Last updated: 2026-08-17
Post by orbis-tertius on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Is there anybody can help me with the same problem? I have to migrate created project in ver.3.5.17.0 32BIT with runtime 4.7.0 to ver.3.5.20.0 64BIT with runtime 4.7.11.0 due to the new license. All the libraries and dependencies are updaded and there are no any errors. The first compilation and loading to the controller is being compleated well. After this being done and if I am forced to change any values or change any code in the current project, another compilation will be freezed. This problem can be solved if pressed Build/cleen or cleen all. There is another method to solve this; if project is loaded with excluded object (Alarm Configuration), repeated compilations will be done well.
Last updated: 2024-06-27
Post by eozupek on File Transfer Error 4
CODESYS Forge
talk
(Post)
I couldn't exactly solve the file transfer when I wanted to do multiple transfers while the compiler was open in a way that I couldn't understand. Notification from target: runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * details of the target component that sent this notification: [CmpName=SysExcept, CmpId=0x00000103, ClassID=0X0001008, ErrorID=0X00000001, InfoID= 0X0000000j] I see the warning. I couldn't find out why error code 4 is coming or what kind of measures I need to take to prevent it from coming within the application. Can you help me? regards Emre OZUPEK
Last updated: 2024-11-24
Post by bmatlove on Re-create CoE online window in Visu
CODESYS Forge
talk
(Post)
Hello, I am trying to re-create the CoE online window within a Visu for purposes of checking and interacting with device parameters occasionally for maintenance purposes. To minimize reliance on using the IDE for misc interactions. Ideally, I would like to exactly mimic the CoE online window within the IDE. I assume that it uses a few tricks to minimize overhead, such as only polling registers which are within the visual scope, for example. I'm afraid it might be too much to ask for a pre-built drop-in Visu module to exist for this task. Do I have any options aside from manually re-creating all the logic to do this, relying heavily on SdoInfo function blocks? Is there a way for me to reference the device ESI file to shortcut the process of determining how many registers there are and getting the address for each?
Last updated: 2025-12-27
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by pavanifm on Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Post)
'--noUI' option of Command line interface for test manager test script not executing when triggered from CI as well as from Local PC however is it working for execution of python scripts from CLI. can we start codesys test manager scripts from CLI interface without any GUI in background process of windows? i can see simlillar questions asked but no answer yet. otherwise, what is the solution to built test automation framework using Test Manager & GIT CI/CD?
Last updated: 2024-08-07
Post by dkugler on EThercat Dynamic configuration
CODESYS Forge
talk
(Post)
I can confirm that at my 4ms EtherCAT Master the frames per second is equal at round about 500 with Codesys SP19. The same program at SP16 it was at 380-430 f/sec. for me it will be interesting too, whats the reason is for this high frame count/sec? I havn't had the time to use a paket sniffer and analyse all the frames. I can't help with your other questions, sorry.
Last updated: 2024-09-19
Post by wbj0t on tool 'update raspberry pi' unavailable
CODESYS Forge
talk
(Post)
Doesnt matter. I have installed sp20 with latest RP 4.13. Same problem. Anyway My large project in RP 4.10 and SP 19 and I need these versions and use same installation programm for Codesys IDE and RP4 package. I did install again, because my SSD broke and now cant update raspberry... I dont know how to translate correctly project to newest version - there are 52769 errors and incompatabilities: after updates libraries anyway some errors still because of devices... I found solution with .deb file from raspberry package - dont need IDE anymore for update raspberry.
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by garmusd on Raspberry Pi 5 GPIO not working.
CODESYS Forge
talk
(Post)
I paid money for the RPi runtime because the Product Description says that GPIO is supported. It is also written in the Versions that since 4.11 RPi5 is supported. And I use 4.13. Nowhere is it mentioned that GPIO is still not supported... It's a pity that the Codesys developers still can't find a way to fix it. Are there plans for when it will be fixed or are the developers too weak? Just wondering, is there anyone with a working GPIO? Can you share the details of your system?
Last updated: 2024-09-27
Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Hello, I have a problem when opening the license manager for my raspberry pi (CM4 model) with runtime 4.13.0.0. I select "Device" --> "Soft Container" and click on my device in the scan window but I get this error message : Licensing info not available. There is no dongle attached to this device. I can't install licenses anymore, and I don't understand why is CodeSys looking for a dongle when I specified I wanted to use a Soft Container. Can somebody help me please ? Best regards
Last updated: 2024-10-04
Post by mini-developer on Profinet Exor connection drop
CODESYS Forge
talk
(Post)
Hello, I have a Exor HMI with 2 seperatred ETH interface's. It is Configured as PN Master on ETH interface 1 and the IO's are working, as long as the development PC is connected to the ETH 0 interface. When the PC is disconnected, the PN communication drops and a reconnection is started. I installed the newest device description for Codesys and Firmware for the Panel. The IO Gateway is from Weidmueller What could cause the Problem?
Last updated: 2024-10-16
Post by winki on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
For small project, I would like to use my industrial computer as a PLC + Industrial Computer. Like that I can save the cost of one PLC. That why I am using Codesys on Linux. With the nic it is not working. I already set the IP adress with /etc/network/interfaces. Can it comes from there ? looking to "Control Linux SL" docuemntation it should work with rtu.
Last updated: 2024-10-23
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
I succeed to change the device to PI_SL but still the same problem of the I2C device switching between running and not running. the only difference with your project is that yo use I2C_master device version 4.7.0 and i 4.7.13, for GPIO i also use the 4.7.13 version and you the 4.7.0. Can you send me the older version of the Raspberry PI pheripals library, because i cannot choose lower version then 4.7.10 for the GPIO and I2C_master device
Last updated: 2024-11-11
Post by aliazzz on Raspberry Pi 3: Linux/ARMHFv7 unknown container technology
CODESYS Forge
talk
(Post)
Hi CODESYS team! It seems Podman for Raspberry Pi 3 is not detected correctly in the latest "Deploy Control SL 4.14.0.0" : Linux/ARMHFv7 unknown container technology. 1) The Communication Tab, device information section shows podman technology as DETECTED. 2) The Runtime Deployment menu message says: "unknown container architecture" 3) The pulldown window under the deployment tab doesn't show the options for ARMHF Virtual Edge SL and ARMHF Virtual Control SL. I hope you can fix this soon and keep up the great work!
Last updated: 2024-12-15
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.