Axis directions in CNC editor not using right-hand rule? CODESYS Forge talk (Thread)
Axis directions in CNC editor not using right-hand rule?
Last updated: 2026-01-08

WebVisu Activity Tracking (no user logged in) CODESYS Forge talk (Thread)
WebVisu Activity Tracking (no user logged in)
Last updated: 2026-03-24

Why Structured SCADA Documentation Matters in Modern Industrial Systems CODESYS Forge talk (Thread)
Why Structured SCADA Documentation Matters in Modern Industrial Systems
Last updated: 2026-05-27

*exception* [processorloadwatchdog] occurred in: app=[all], task=[all] CODESYS Forge talk (Thread)
exception [processorloadwatchdog] occurred in: app=[all], task=[all]
Last updated: 2026-02-10

How to use MQTT in CODESYS Control Win V3 CODESYS Forge talk (Thread)
How to use MQTT in CODESYS Control Win V3
Last updated: 2026-02-25

Control Omron G5 servo drive in Torque mode CODESYS Forge talk (Thread)
Control Omron G5 servo drive in Torque mode
Last updated: 2026-03-08

Escape character behavior for hex values in string -- what gives? CODESYS Forge talk (Thread)
Escape character behavior for hex values in string -- what gives?
Last updated: 2026-03-09

RS232 Communication in CODESYS Control RTE V3 CODESYS Forge talk (Thread)
RS232 Communication in CODESYS Control RTE V3
Last updated: 2026-03-14

Buttons with rounded corners in flat style CODESYS Forge talk (Thread)
Buttons with rounded corners in flat style
Last updated: 2026-03-16

CODESYS device discovery performance in large networks (/16) CODESYS Forge talk (Thread)
CODESYS device discovery performance in large networks (/16)
Last updated: 2026-03-29

How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Thread)
How change Unity-ID in TCP Modbus Slave
Last updated: 2026-04-20

1 Wire und i2c zeitgleich in Betrieb CODESYS Forge talk (Thread)
1 Wire und i2c zeitgleich in Betrieb
Last updated: 2026-04-27

Post by fabian on Sys Process Execute Command CODESYS Forge talk (Post)
Hello, I have a question: Once the command is being executed, is there a way to kill it again? As the called application is running in the background, the user can't close it but it shall be closed/terminated, commanded by codesys. I have tried with "SysProcessTerminate" but I guess this is not correct as the RTE crashes when this function is called. Starting the application: IF GVL.xStrtQR THEN GVL.xStrtQR := FALSE; SysProcess.SysProcessExecuteCommand2(pszCommand:=sCmd, pszStdOut:=stdout, udiStdOutLen:= SIZEOF(stdout),pResult := ADR(GVL.pResQRTsk)); END_IF Trying to stop it again: IF GVL.xTrmQR THEN GVL.xTrmQR := FALSE; pResTerm := SysProcess.SysProcessTerminate(hProcess:=SysProcess.SysProcessGetCurrentHandle(pResult:=ADR(GVL.pResQRTsk))); END_IF Codesyscontrol Win x64, 3.5.19.10. Many thanks for any advice pointing to the correct direction.. :-) Regards, Fabian
Last updated: 2023-11-17

Post by struccc on HTML5 Controls - string(>80) values CODESYS Forge talk (Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23

Post by mazino on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ? CODESYS Forge talk (Post)
Hi starmaxou, I’m facing the same issue you mentioned with the dependencies for the CODESYS Control for Linux SL installation. I was able to find the manual downloads for the CODESYS Edge Gateway and CodeMeter, but I’m still stuck on the other two dependencies: CODESYS Control SL Extension v4.0.0.0 CODESYS Control SL Deploy Tool v4.10.0.0 Since you’ve encountered the same problem, I’d really appreciate any help or insights you can share on how you were able to resolve it. Any tips or suggestions would be greatly appreciated! Thanks in advance!
Last updated: 2025-03-07

Post by pernockham on How to manage soft container licenses for (remote) multi units? CODESYS Forge talk (Post)
Using Codesys runtime for Linux and thinking of the process of preparing multiple such systems for my customer. I don't necessarily have physical access to these units, they can be (very) remote. The idea so far is to use an image to install the Linux OS and codesys runtime. Application updates can be done by distribution of the PlcLogic/Application/application.app and application.crc files. But whats the most practical way of managing the license for these units? Do each controller need to be physically connected to a License Manager instance or can licenses be distributed by means of a license file for each unit? I believe that the license should be stored in soft containers for each unit. Help and insights appreciated! Per
Last updated: 2025-04-04

Post by ac-spr on Runtime variable that indicates a user is online to the code CODESYS Forge talk (Post)
Looking to access a variable at runtime that indicates a user is online to the code. essentially want to use this value to feedback to the user on the HMI. we use turck and bosch rexroth devices if this information helps. I was hoping there was a variable at the application level, or a library that could be used but I was unable to find anything. I know there's a pop up when you try to login/ go online to the code when a user is already logged in, so the system does provide an indication that it knows already online, but has no access to a value from what I can see. Any help is appreciated
Last updated: 2024-04-22

Post by peterned on CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that? CODESYS Forge talk (Post)
Hi, I have a XY system and use a CNC file to move it. Everything works OK, except for the following: when CNC execution starts, the system rushes at high speed to (X=0, Y=0) point, and only then goes to the first line of the CNC file. If one of the axes is near 0, the system jumps and immediately stops with an error. In the CNC file settings (screenshot attached) I specified low default values for speed/acceleration and a start position different from 0,0 - but all that is ignored. Any idea how to avoid that move to 0,0 ? Thanks.
Last updated: 2024-04-26

Post by spice on WebVisu Recipe Save/Load CODESYS Forge talk (Post)
I'm currently reworking the controls on a cnc press brake and wanted to load various recipes as programs to run. I'm using a 2d array of REALs to store the X and Y coordinates as well as some other program parameters in a recipe. I'd like to store all of the recipes on a computer used as the HMI that way the text files can be edited and uploaded offline. I'm using Automation Directs P2CDS-622 Can this be done through webvisu? If not would a license for Codesys HMI SL on the computer allow me to accomplish this? I've attached the Project File Thanks, Spice
Last updated: 2024-05-31

Post by jens on Modbus tcp - channel CODESYS Forge talk (Post)
Help wanted This is the first time i'm doing a Modbus Tcp project. I have some VLT with a extension module MCA-122. i'm currently unable to write to the VLT slave, but i can read from status word parameter=1603 and address := 16029 where the address is calculated from parameter is ((id x 10)-1). in the manual the functions that are supported are 3 hex, 6 hex, 10 hex, b hex and 11 hex. read holdin registers, write single register, write multiple registers, get comm. event counter, report slave id. i'm only using the Modbus Slave Channel is this wrong when trying to write to the vlt ?
Last updated: 2024-06-13

Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables CODESYS Forge talk (Post)
Trying the web-version of trend-data. This seems to be a impressive tool, but I lack/cant find a number of what I would think are important parts. There does not seem to be a way to get away from the dot.notated variable naming in the legend.. A developer might want the dot-notation but an end-customer will surely not. For instance I want to display 12 temperatures, instead of t1, t2 etc.. they will be named. gvl_io.unit[1].trend.temps.t1_a gvl_io.unit[1].trend.temps.t1_b gvl_io.unit[1].trend.temps.t1_c gvl_io.unit[1].trend.temps.t2_a .. gvl_io.unit[1].trend.temps.t4_b.. gvl_io.unit[1].trend.temps.t4_c.. Quite a lot of unnecessary text/data taking space from the actual trend => Is there a way to access/interface the legend-data programmatically so I can change the presentation/naming?
Last updated: 2025-12-16

Post by alex-n on Problem with keeping up the distance between two axes CODESYS Forge talk (Post)
Hello. I have a task to synchronize the movement of two axes and maintain the distance between them. First axe makes equal steps by trigger using MC_MoveRelative function. The second one is standstill and after another signal should catch up the first one from its position to a specified distance and keep it. I've tried to use MC_Phasing and mostly it works. Second axe catches up the first and starts make step with it. But in one moment this axe can crash into the first and there is no clear connection as to why this is happening. It can work correct for a day or for a week.
Last updated: 6 days ago

Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error CODESYS Forge talk (Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22

Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error CODESYS Forge talk (Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22