Post by kaotic2499 on Upgraded Raspberry 2b to Raspberry 5, Trends Broken? CODESYS Forge talk (Post)
There is currently a bug with the Raspberry Pi 64 SL where it is unable to Trend Global Retain or PersistantVars. The work around is to use standard Global Variables for Trend Data. This will be patched by Codesys in the near future reference "VIS-6170"
Last updated: 2025-11-13

Post by poliautomacao on Absolute movement controlled by an external encoder. CODESYS Forge talk (Post)
Hello, is it possible to perform an MC_MoveAbsolute movement, and have the servo move using an external encoder (freeEncoder)? In my application, I have slippage on the main shaft of the servo motor, and I would like to add an encoder to measure the actual position of the material.
Last updated: 2026-03-04

Post by reinier-geers on Network variable stops sending CODESYS Forge talk (Post)
I use network variables. But when i change the programm, it wil stop sending. Then is have to add or delete a variable. Then i will be compiled again and sends again. This problem wasw already in 9.20 but seems to be still in 21.0 . Is there a way to solve this ?
Last updated: 2026-04-20

Post by mondinmr on COL.IMap2 and HashTableFactory cause frequent Access Violation CODESYS Forge talk (Post)
Good morning, I’ve been using the Collection library for a long time, mostly with Stack, LinkedList, and List. From your examples I was able to manage the different factories, even for custom elements. Now I need a hashtable, but with this object I’m running into a lot of random access violations. If I append something inside FB_Init after constructing the hashtable, it crashes, even though the list was already created. If I only create the hashtable in FB_Init and append afterwards, it usually works. I don’t understand the meaning of the dispose call in this code: pSlave := ADR(slave); uSlave := TO_ULINT(pSlave); iKey := fKey.Create(uSlave); IF hash.CountKeys() = 0 THEN Service.logger.appendLog('Filling hashtable', 'HashManager', AdvLogType.AdvDebugMsg); ok := FALSE; ELSE eError := hash.ContainsKey(iKey, xResult => ok); END_IF IF NOT ok THEN pI := __NEW(UINT); iVal := fKey.Create(TO_ULINT(pI)); Service.logger.appendLog(CONCAT('New slave', TO_STRING(uSlave)), 'HashManager', AdvLogType.AdvDebugMsg); hash.AddKeyValuePair(iKey, iVal); appendNewSlave := pI; ELSE eError := hash.GetElementByKey(iKey, itfValue => iElem); xResult := __QUERYINTERFACE(iKey, itfIInstance); IF xResult THEN itfIInstance.Dispose(); END_IF IF eError <> COL.COLLECTION_ERROR.NO_ERROR THEN Service.logger.appendLog(CONCAT('ERROR ', TO_STRING(eError)), 'HashManager', AdvLogType.AdvCriticalMsg); appendNewSlave := nullptr; RETURN; END_IF __QUERYINTERFACE(iElem, iVal); {warning disable C0033} pI := TO___UXINT(iVal.UlintValue); {warning restore C0033} appendNewSlave := pI; END_IF Without the dispose call, every second cold reset crashes immediately when I try to access iVal, even if eError doesn’t report any error. With the dispose call, the cold reset issue disappears, but I get other problems: a) If I start the runtime using systemctl start codesyscontrol, it crashes at IF hash.CountKeys() = 0 THEN b) If I delete the files in PlcLogic and download again, it works and survives multiple cold resets. But as soon as I run systemctl restart codesyscontrol, everything gets corrupted again and it starts crashing at that point. FUNCTION_BLOCK SlaveMapCounter VAR hash : COL.IMap2; eError : COL.COLLECTION_ERROR; END_VAR In its FB_Init I create it: METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR hF : COL.HashTableFactory; END_VAR hash := hF.Create(256); In another FB I instantiate it statically: FUNCTION_BLOCK ABSTRACT AbstractServoEthercatController EXTENDS AbstractServoController VAR_STAT hashSlaves : SlaveMapCounter; END_VAR VAR field : REFERENCE TO ADVAbstractFieldUnitEthercatCia402; initCnt : REFERENCE TO UINT; END_VAR The append method is the one shown above, and I call it after the runtime has started. The accesses are performed by a single task, and in any case I’m working on an isolated single core. I’ve tried everything, moving the create, the instances, and all the rest several times, but nothing seems to work. I’d like to point out that these FBs are part of our own library, which is used in many applications.
Last updated: 2025-09-11

Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys. CODESYS Forge talk (Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18

Post by mozed on Connection to device closed CODESYS Forge talk (Post)
i found this error in /opt/CoDeSysControl/Files
Last updated: 2023-08-25

Post by timvh on CANbus issue CODESYS Forge talk (Post)
On a PC with the Control Win, this is probably related to the fact that the CAN drivers are not loaded. Go to the folder where your Control Win Configuration file is: - E.g. C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE - Open the CODESYSControl.cfg - Remove the semi-colon in front of the CAN driver you want to use (section ComponentManager). - Set the component ID to the next number in the list (e.g. Component.8) - Save this file and restart the Control Win.
Last updated: 2023-09-14

Post by aott33 on Webvisu NO load CODESYS Forge talk (Post)
Thanks, I will check the PLC Log when the PLC is connected again. I will update my findings here. Since I don't have access to the Linux Panel PC at the moment, I tested inside my development VM with the same Linux OS. I have no issues or delays connecting to the WebVisu using my Linux VM. Two main differences: 1. My host Computer has a faster processor compared to the panel PC. 2. There are no devices connected in my dev environment. I will continue testing when I have connection to the panel PC.
Last updated: 2023-09-23

Post by eschwellinger on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
which PFC Firmware is this? -check with wbm
Last updated: 2023-09-28

Post by ofey on Symbol configuration / GVL CODESYS Forge talk (Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11

Post by ofey on Symbol configuration / GVL CODESYS Forge talk (Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11

Post by rafaelbrito on User management - User Tab missing CODESYS Forge talk (Post)
Click in "Convert to Legacy"
Last updated: 2023-10-17

Post by davidbo on RPI is license server down CODESYS Forge talk (Post)
I try to install license on server license.codesys.com.
Last updated: 2023-10-18

Post by eschwellinger on install codesys runtime on linux CODESYS Forge talk (Post)
could you try to add the command in Tools-customize
Last updated: 2023-11-04

Post by totorovic on Pointer to Softmotion axis CODESYS Forge talk (Post)
I get the same warning message with initialized variable. Codesys 3.5.19.20
Last updated: 2023-11-09

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
It's already there, the service get started as default. I missed to say that sometimes it happens w/o even the system get restarted. Anyway, the main issue here is to know the state of the runtime. We collect a lot of informations about the whole system, and it would be nice to have a way to detect the runtime state.
Last updated: 2024-07-02

Post by wollvieh on Trouble Writing Files to External Paths in CODESYS CODESYS Forge talk (Post)
https://content.helpme-codesys.com/de/CODESYS%20Control/_rtsl_windows_win_v3_dynamic_components.html
Last updated: 2024-07-05

Post by disha on SQLITE connection CODESYS Forge talk (Post)
Are you able to do it? Can you please help me out?
Last updated: 2024-07-08

Post by ahuckphin on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
I have a DFRobot RS485 temperature & humidity sensor (SEN0438) connected to my Raspberry Pi via a USB to RS485 adapter. I am able to connect and read the sensor data when running a python code locally. However in Codesys, I encounter this error "A bus error has occurred." and "There was no response in time". Could this be because of Modbus Server Channel and Modbus Server Init configuration on my part? Admittedly I am new to Codesys. To get to this stage, I: 1. added some lines to CODESYSControl_User.cfg 2. added "Modbus_COM" in Codesys and set "Serial Port Configuration" under "General" 3. added "Modbus_Master_COM_Port" in Codesys and checked transmission mode is set to "RTU" 4. added "Modbus_Slave_COM_Port" in Codesys and checked server address is set to 1 (also set 1 in my sensor) 5. added 1 channel and 1 init for "Modbus_Slave_COM_Port" under "Modbus Server Channel" and "Modbus Server Init"
Last updated: 2024-07-10

Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
I had my problem solved.
Last updated: 2024-07-10

Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
I had my problem solved.
Last updated: 2024-07-10

Post by timvh on Send data to USB CODESYS Forge talk (Post)
https://forge.codesys.com/prj/codesys-example/file-utilities/home/Home/
Last updated: 2024-07-22

Post by abrarsk on SysCom Library Usage CODESYS Forge talk (Post)
Link to library: https://content.helpme-codesys.com/en/libs/SysCom/Current/index.html
Last updated: 2024-08-05

Post by vladimirsmall on Send data to USB CODESYS Forge talk (Post)
Thank you on support
Last updated: 2024-08-05

Post by trusty-squire on parker servo and position CODESYS Forge talk (Post)
Glad to hear it 🙂
Last updated: 2024-08-07