Post by imdatatas on C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
Hello everyone, I downloaded the "Example: PLC Chat Net Base Services" example from the Codesys help site to review and try it out. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_cds_plc_chat_net_base_services.html However, when I open and compile the example program with SP21 Patch2, I get the strange error message below regarding Visualisation component, and it fails to compile. " [ERROR] visuelems, 4.8.0.0 (system): VisuFbTabControl: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr " Are others experiencing the error "C0138: No matching 'FB_Init' method found for instantiation..." when trying to compile example projects created with older versions of Codesys with a later version of the IDE? How did you overcome this problem? Could you share your solutions? Regards, Imdat
Last updated: 2025-08-26
Post by blitz on Arcs intersection
CODESYS Forge
talk
(Post)
Does anyone have an idea how to run such a spiral on CNC smoothly without stops? SMC_SmoothPath and SMC_RoundPath don’t help. In general according to the documentation they should work on arcs but in the example only straight lines are shown and I get the impression these functions only work for straight lines. N005 G51 D15 N010 G01 X120.00 Y120.72 F100 N020 G03 X110.00 Y130.72 I-10.00 J0.00 F100 N030 G03 X100.00 Y120.72 I0.00 J-10.00 F100 N040 G03 X140.00 Y120.72 I20.00 J0.00 F100 N050 G01 X140.00 Y120.72 F100 N060 G03 X80.00 Y120.72 I-30.00 J1.67 F100 N070 G01 X80.00 Y120.72 F100 N080 G03 X160.00 Y120.72 I40.00 J-1.25 F100 N090 G01 X160.00 Y120.72 F100 N100 G03 X50.00 Y120.72 I-55.00 J-5.00 F100 N110 G01 X50.00 Y120.72 F100 N120 G03 X190.00 Y120.72 I70.00 J-0.71 F100 N125 G50 N130 M30
Last updated: 2025-09-23
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Dear Forum I have the following config: Codesys_IDE 3.5.20 Codesys_Virtual_Control 4.13 Codesys_License_Server 4.13 I know these are not the newest versions, but in my mind these should work. I have the same problem here. I have the license server installed on the host, and in the docker container(Codesys virtual control) I'm able to ping the license server. In the /conf/codesyscontrol/CODESYSControl_User.cfg I have added the following config: [CmpCodeMeter] EnableNetLicenses=1 LicenseServer.1="ip address of the host" I have tried it via the wbm web-page. I can create new license containers over there, but still no luck. I also have tried to run the docker container with the -s "server_IP" command. I have searched for some tutorial's but I couldn't find it. If anyone has some clue or can give me a push in the right direction it would be very very welcome!
Last updated: 2025-09-29
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Thank you for the response, The empty softcontainer does not become visible unfortunately, but I think I can get that back to working. I think I'm misunderstanding something. You are pointing to the Softcontainer number and the ticket code, I thought that I needed to fill in the virtual control containers serial code is this a misunderstanding? And if this is indeed the case, how is the link between the server (softcontainer) and the Codesys control docker container made? If I have multiple Codesys docker containers running on the same docker server, how is the correct license distributed to the correct Codesys runtime container?
Last updated: 2025-10-02
Post by reinier-geers on Web client
CODESYS Forge
talk
(Post)
Hi, ive got the webclient example. So now i want to use it. Ive got an example. but thats some JSON type. As far i know is JSONe som kind of structure. But thats new for me. I think its posible with get. Can someone help me? This is the link witch explains what to do https://reversed.notion.site/Marktprijzen-API-89ce600a88ac4abe8c2ad89d3167a83e i tried this : sURL : STRING(1024) := 'https://graphql.frankenergie.nl/get/ {"query":"query MarketPrices {\n marketPrices(date:\"2022-01-01\") {\n electricityPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n gasPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n }\n}\n"}'; // URL But thats a bad request
Last updated: 2025-10-08
Post by mohammadasif on Blink Function definition is wrong in codesys online help
CODESYS Forge
talk
(Post)
https://content.helpme-codesys.com/en/libs/Util/Current/Signals/BLINK.html in the above link, please correct your website the following: "Output value, starts with FALSE and switches between TRUE and FALSE for the given high and low times" it should actually be: "Output value, starts with TRUE and switches between TRUE and FALSE for the given high and low times" if not please let me know if this has changed in a util library update, in your older website it has the right definition here: https://help.codesys.com/webapp/blink;product=codesys;version=3.5.11.0
Last updated: 2023-12-28
Post by idalu on Profinet PN_Controller Issue, Network Adapter
CODESYS Forge
talk
(Post)
i have a problem with Profinet on my project. I'm using Codesys RTE 3.5.19.50. When i download program to controller the ethernet is ok, PN_Controller is ok but every device i'm trying to connect is red with error "DCP no RealStationName". When i'm trying to Scan for Devices on PN_Controller there are no devices found. I have installed Codesys driver CmpEt1000Drv to my network adapter (i'm sure it is right intel pro 1000 model). I have noticed that when i installed codesys driver i'm no longer able to ping this network adapter (i can ping it when intel driver is installed). On my previous projects with runetimes i can ping it even with codesys driver installed. I have also tried to do downgrade of everything to version 3.5.19.20 and it not helped.
Last updated: 2024-01-17
Post by talpade on WAGO PLC 200 750-8216 Ethernet connection to Codesys 3.5
CODESYS Forge
talk
(Post)
Hello, I have the WAGO PLC 200 750-8210. In addition I have downloaded the "WAGO Devices and Libraries 2.0.4.3" and installed the library into the Codesys v 3.5. I then create a new project on Codesys 3.5 and select the device "750-8216 PFC200 (WAGO)" (which I downloaded from the WAGO library). However when I have connected the ethernet cable from the WAGO device to my computer and on my codesys 3.5 i press "Scan Network" on codesys and it does not detect the device. How can I get it to detect the device? (I have put the ethernet cable from my WAGO to the computer, but it does not show the device).
Last updated: 2024-02-05
Post by riccardo on Web Browser special tools errors
CODESYS Forge
talk
(Post)
Goodmoning everyone, I hope a codesys tecnichian will see this post. I serched on the forum and I found many topic about this tool but very few reaplies. I am tring to use the Web Browser tool, but it doesn't seem to work properly. I put several links in several forms: https://google.com http://google.com/ http://www.google.com http://www.google.com/ http://www.studiojomega.it/ . . . https://192.168.1.101/u-os-app-codesys/application/visualization/webvisu.htm But I obtain always errors; mainly 400 and 404 and in the normal visu this message appears "www.Google.com has refuse the connection". Is the codesys browser able to work as every other browser or has it some limitation? There is some particular precaution to consider when I pass the link to the codesys browser? Thanks in advance, Riccardo
Last updated: 2024-02-29
Post by nilesh on Request for Assistance with Online Logic Changes in PLC System using Codesys
CODESYS Forge
talk
(Post)
Dear Sir, We are writing to seek guidance regarding our current situation with the Opto 22 Groov EPIC PR1 PLC system. Over the past year, we have successfully downloaded and implemented logic using Codesys, and the PLC has been operational without issues. However, we now require minor modifications to the logic. Despite attempting to upload the modified logic, we are unable to see the "online change" option, prompting us to consider a direct logic download. Our concern is that during this process, certain digital outputs or analog outputs might momentarily disrupt operations, which is unacceptable given the system's continuous 24x7 operation. We have explored online changes in other PLC systems, but due to the absence of the last downloaded backup, we are unable to proceed confidently.
Last updated: 2024-03-01
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by esave on Softmotion Light Problem: The license is missing or invalid
CODESYS Forge
talk
(Post)
Hello everybody I want to controll a stepper driver from Leadshine (EM3E-556E). The EtherCat slave is CiA 402 compatible. Because of this I bought the Softmotion Light Package from Codesys and implemented it in my project. I rightclicked the EtherCat slave and added the Softmotion Light axis. But now the error message shows: "The license is missing or invalid. The PLC runs in demo mode." What have i done wrong? I use Codesys 3.5.17. Is it possible that the stepper driver is not compatible with the Softmotion license? Thanks for all your help
Last updated: 2024-05-02
Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred!
CODESYS Forge
talk
(Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08
Post by timl on Application has invalid license metrics
CODESYS Forge
talk
(Post)
Hallo, ich habe eine Control for Linux SL auf der ich einen TCP Modbus Master anlege, mit dem ich einen Slave auslesen möchte. Das Anlegen funktioniert soweit alles, sobald ich beim ModbusTCPSlaveE/A-Abbild in den Channel eine Variable einfüge, damit ich den Channel auslesen kann, kommt es beim übertragen auf die SPS zu einem Ausnahmefehler. Im Anhang noch eine Bilder der Fehlermeldung und der installierten Lizenzen. CODESYS Version ist V3.5 SP19 Patch 4 Meinem Verständnis nach ist die Modbus Lizenz mit in der Control Standard L inbegriffen und auch in der Lizensierten Softwaremetrik sehe ich keine überschreitung meiner Lizenzbegrenzungen. Daher verstehe ich nicht wieso ich diesen Fehler bekomme und eine auslesung via Modbus nicht möglich ist. Gruß Tim
Last updated: 2024-05-08
Post by mborchert on PFC100 Error "Bus not running"
CODESYS Forge
talk
(Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
I have been struggling for over a week to program my rapspberry pi 4 with codesys. I purchased the license. I installed the runtime and the gateway, and I can see the pi in the communication settings. But cannot log in. I have checked the status of the pi with sudo systemctl status codesyscontrol and it is running. I have enabled traffic to and from the pi with iptables and checked the logs and all looks good. I just cannot connect through the codesys ide. Can anyone help me before I lose my mind?
Last updated: 2024-06-22
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
I have been struggling for over a week to program my rapspberry pi 4 with codesys. I purchased the license. I installed the runtime and the gateway, and I can see the pi in the communication settings. But cannot log in. I have checked the status of the pi with sudo systemctl status codesyscontrol and it is running. I have enabled traffic to and from the pi with iptables and checked the logs and all looks good. I just cannot connect through the codesys ide. Can anyone help me before I lose my mind?
Last updated: 2024-06-22
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by mr-ege on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
Hi all! I'm trying to learn PLC Programing. Today I was making a simple PLC program, as you can see. When I compile the program without the visualization, there are no errors. However, when I add the visualization and then compile it, I get this error. I don’t know how to solve the problem. I have tried the following solutions: rebooting the PC and updating the software. Error Code: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr Compile complete -- 1 errors, 0 warnings Build complete -- 1 errors, 0 warnings : No download possible Version: CODESYS V3.5 SP21 Patch 3
Last updated: 2025-11-25
Post by artem1223 on Synaxis of library declarations in the ST
CODESYS Forge
talk
(Post)
Codesys 3.5 17.30, plc - crevis GN-9373. I need to use RTC of pls for write in registers (need to check difference of writen 100 and 200 registers). For this i try to use SysTimeRtc (SysTimeRtc.SysTimeRtcGet) but its not working. After it i tryed to use SysTimeGetMs and something like this but still not working. Library? Mb but check project, SysTime with SysTimeRtc already, all what i know - already is here. Its my first try to learn ST (early used fbd and ladder, yeah), pls help with it. Mb problem with a syntaxis, but im not sure.
Last updated: 2025-11-26
Post by imdatatas on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr
CODESYS Forge
talk
(Post)
Unfortunately, the "C0138: No matching 'FB_Init" method found" error is a nightmare for CODESYS V3.5 SP21. I'm not sure if anything has been done about this or if anything will be fixed. I've encountered the same issue many times, and it was only resolved by completely uninstalling SP21, deleting all related files and folders from my computer, and then installing SP19. So, I've given up on using SP21 and switched back to SP19patch7. Here are some previous posts regarding the "C0138: No matching 'FB_Init" on SP21 of Codesys. https://forge.codesys.com/forge/talk/Visualization/thread/0763d6ca8e/ https://forge.codesys.com/forge/talk/Motion/thread/9074005bf4/
Last updated: 2025-11-28
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
The option to update "Control for Linux SL" is not shown in the "deploy control SL tool", I can see and update the gateway but not the control (3.5.21 SP4). Has the way to update control SL changed? In the process of fault finding I removed the control SL entirely from my target, then I had to revert to version 3.5.21.0 SP 1 to re-install "Control SL 4.17.0.0". So I thought it was just a matter of using SP1 to update also to 4.18.0.0, but after installing the files for 4.18.0.0 in the SP1-version, the behavior was identical to SP4, ie no Control for Linux SL shown in the deploy tool.. See screenshots.
Last updated: 2025-12-19
Post by timvh on Codesys complains about matching versions
CODESYS Forge
talk
(Post)
Open the CODESYS Installer. Create an export file from your current PC from your current version. Then on the other PC Open the installer and install a new version based on the same essentials version, but additionally select the export file which you have created on the first PC. Or just install (import) it within the already existing version. For the installer, you can install it from: https://store.codesys.com/en/codesys-installer.html For help see: https://content.helpme-codesys.com/en/CODESYS%20Installer/_inst_install_setups_and_addons.html On PC 1, save the project as projectarchive (which will then include all the libraries and devices). Then extract this projectarchive on PC 2.