Post by alexgooi on Modbus TCP interface get stuck
CODESYS Forge
talk
(Post)
Dear Forum, I'm currently experimenting with Modbus interfaces in combination with a virtual controller. I have the following setup (Modbus_Setup.png): I have an IPC with Debian installed on it (Debian 13). On this Debian machine I have installed a docker server and on this docker server a Codesys runtime container is deployed (Codesys_image.png). The Modbus scanner makes connection with and IO coupler and this works well. But when I physically disconnect the ethernet connection between the IPC and the IO coupler the Modbus interface gets stuck in a state where it gets stuck in the busy state (Modbus_Stuck.png). When I plug the cable back in, the IO coupler isn't communicating until the xBusy variable is manually set to False, after this action is performed the communication goes back to normal. I have tried to set the container network to host and bridge (Network.png), but both version gives the same result (stuck scanner). I would expect that the Modbus interface is generating a timeout after 1 sec, because this is how it is setup (Modbus_settings.png), but this is not what happens. I have thought to write a piece of code that writes xBusy to false when it is stuck but because it is an output I'm not able to write to it. I have tried this with another PC (different CPU/motherboard) but this gives the same outcome. I tried updating to the latest version of Virtual control (4.20) but this gives the same result. I also tried to do the same thing with an ethernet IP scanner, and this gives an error after the timeout is expired (so this works well). I have tried to connect to the IO coupler using the Modbus_FB lib (Modbus_FB.png) the FB's are giving the correct errors and behaving as expected. At last I have tried to use a Scanner on a Codesys controller (no IPC) and here the scanner behaves as expected (an alarm is triggered after the timeout has been expired). The version of the Codesys components are listed in the picture Versions.png Is there anyone that can give me a push in the right direction? Kind regards Alex
Last updated: 2026-04-14
Post by pruwetbe on Profinet IO-link master - IODD files
CODESYS Forge
talk
(Post)
Hello, we have the same problem here. Our configuration in the following: Codesys V3.5 SP19 running on Exor Exware700Q Profinet network connected on Eth1 IOLink Master Turck TBEN-S2-4IOL version 3.5.9.0 IOLink sensors E+H & Sick (Pressure, T°) We installed the codesys IO link package and have the codesys IO Link SL licence activated (on a dongle) Our problem is the following: we got the IODD files from E+H & Sick we add the devices in the codesys device repository with success They appear in the devices tree under IODD branch We added the TBEN IOLink master under the Profinet IO . The IO link master are ok and display online. The IO-Link SL package datasheet indicate that there would be a way to scan the IOLink device from the network but we did not find any way to trigger this scan. (we expect to get this from a right click on each IO-Link Master module but the only possibility there is "Plug device") When clicking on Plug Device, we get a browse window with profinet IO modules. The IODD devices are not there so we cannot select them. But other devices for other brands are available and can be plugged. Our question are : 1) how do we update the Profinet IO Module catalogue in order to be able to plug the E+H & Sick Sensors that we have to work with? 2) how do we activate the Scan IOLlink device that is supposed to be included in the Codesys IO-link package? 3) where can we find the manual explaining how to use this package?
Last updated: 2024-11-12
Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Thread)
Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
Last updated: 2023-08-26
CODESYS Automation Server Connector for 3.5 SP11
CODESYS Forge
talk
(Thread)
CODESYS Automation Server Connector for 3.5 SP11
Last updated: 2023-08-30
Introductory short video series on PLC programming (CODESYS)
CODESYS Forge
talk
(Thread)
Introductory short video series on PLC programming (CODESYS)
Last updated: 2023-08-28
Network Variable List in Codesys 3.5 on CAN
CODESYS Forge
talk
(Thread)
Network Variable List in Codesys 3.5 on CAN
Last updated: 2023-08-05
How to read structure in CodeSys using pythong script?
CODESYS Forge
talk
(Thread)
How to read structure in CodeSys using pythong script?
Last updated: 2017-10-09
Barcode-Reader O2I (TCP/IP) mit Codesys auslesen
CODESYS Forge
talk
(Thread)
Barcode-Reader O2I (TCP/IP) mit Codesys auslesen
Last updated: 2018-04-01
Compiling CoDeSys project using the command line interface
CODESYS Forge
talk
(Thread)
Compiling CoDeSys project using the command line interface
Last updated: 2021-01-27
General question about Codesys and control RTE
CODESYS Forge
talk
(Thread)
General question about Codesys and control RTE
Last updated: 2020-01-27
Using ScriptEngine in C# for Creating Codesys Project
CODESYS Forge
talk
(Thread)
Using ScriptEngine in C# for Creating Codesys Project
Last updated: 2019-06-24
Newbie questions regarding CodeSys V3 Modbus RTU
CODESYS Forge
talk
(Thread)
Newbie questions regarding CodeSys V3 Modbus RTU
Last updated: 2016-06-09
Codesys Wago Going Online from Different Computer
CODESYS Forge
talk
(Thread)
Codesys Wago Going Online from Different Computer
Last updated: 2022-12-15
Adding a CANBUS device on Codesys Control Linux SL
CODESYS Forge
talk
(Thread)
Adding a CANBUS device on Codesys Control Linux SL
Last updated: 2022-05-25
CODESYS Control Not Showing Up in Devices
CODESYS Forge
talk
(Thread)
CODESYS Control Not Showing Up in Devices
Last updated: 2023-01-02
Datenaustausch zwischen mehreren Codesys-SPS in Echtzeit
CODESYS Forge
talk
(Thread)
Datenaustausch zwischen mehreren Codesys-SPS in Echtzeit
Last updated: 2022-11-18
Codesys 2.3 Größere Texte, Strings in Visu darstellen
CODESYS Forge
talk
(Thread)
Codesys 2.3 Größere Texte, Strings in Visu darstellen
Last updated: 2010-12-10
CoDeSys Beipiel mit Balluff Ident-System gesucht.
CODESYS Forge
talk
(Thread)
CoDeSys Beipiel mit Balluff Ident-System gesucht.
Last updated: 2009-02-03
Importing variable list from Excel into Codesys
CODESYS Forge
talk
(Thread)
Importing variable list from Excel into Codesys
Last updated: 2018-03-21
Codesys Soft PLC connection to TOP OPC UA- Server
CODESYS Forge
talk
(Thread)
Codesys Soft PLC connection to TOP OPC UA- Server
Last updated: 2021-03-22
[FATAL ERROR] Unresolved reference: 'USERMGRUSERGETPROPERTY' on Codesys 3.5 SP19
CODESYS Forge
talk
(Thread)
[FATAL ERROR] Unresolved reference: 'USERMGRUSERGETPROPERTY' on Codesys 3.5 SP19
Last updated: 2023-04-02
CODESYS Automation Server Connector [1.12.0.0] Installation Error
CODESYS Forge
talk
(Thread)
CODESYS Automation Server Connector [1.12.0.0] Installation Error
Last updated: 2020-09-12
Disable Codesys communication on fieldbus ethernet card
CODESYS Forge
talk
(Thread)
Disable Codesys communication on fieldbus ethernet card
Last updated: 2022-06-13
Problem beim Starten der Codesys Runtime auf einer PFC200
CODESYS Forge
talk
(Thread)
Problem beim Starten der Codesys Runtime auf einer PFC200
Last updated: 2019-10-14
Questions refering Codesys OPC UA PubSub Library
CODESYS Forge
talk
(Thread)
Questions refering Codesys OPC UA PubSub Library
Last updated: 2021-03-19
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.