Map in Codesys
CODESYS Forge
talk
(Thread)
Map in Codesys
Last updated: 2024-04-04
Error in simple division
CODESYS Forge
talk
(Thread)
Error in simple division
Last updated: 2024-04-25
FB_INIT in library
CODESYS Forge
talk
(Thread)
FB_INIT in library
Last updated: 2024-05-23
CM4S GPIO's in Codesys
CODESYS Forge
talk
(Thread)
CM4S GPIO's in Codesys
Last updated: 2024-05-28
Alarm status in logic
CODESYS Forge
talk
(Thread)
Alarm status in logic
Last updated: 2024-06-06
OpenDir always in error
CODESYS Forge
talk
(Thread)
OpenDir always in error
Last updated: 2024-08-01
Visualisaion while in simulation
CODESYS Forge
talk
(Thread)
Visualisaion while in simulation
Last updated: 2024-08-02
%t SystemTime in Variable
CODESYS Forge
talk
(Thread)
%t SystemTime in Variable
Last updated: 2024-08-20
Type mappings in Datasource
CODESYS Forge
talk
(Thread)
Type mappings in Datasource
Last updated: 2024-09-12
Visualization Toolbox in German
CODESYS Forge
talk
(Thread)
Visualization Toolbox in German
Last updated: 2024-09-26
Axis references in visualization
CODESYS Forge
talk
(Thread)
Axis references in visualization
Last updated: 2024-10-17
Post by george32 on CSV file and string manipulation.
CODESYS Forge
talk
(Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27
Post by kevinl on RevPi Connect RS485
CODESYS Forge
talk
(Post)
I figured this out on my own with this logic: usually the Serial port on a Raspberry pi is on /dev/ttyUSB0 then you need to set linux.DeviceFile=/dev/ttyUSB in codesys you then must set com port to 1 so i assumed codesys subtracts 1 from the number and adds this to the filename... (in code it would look like this: var comPort : byte := '1'; linuxDevice : string := '/dev/ttyUSB'; filename : string; end_var filename := concat(linuxDevice, (to_string(comPort-1)); filaname then is /dev/ttyUSB0 RevPi uses ttyRS485 as Serial port so you must remove the last number from the name and set the com port to this number +1 i hope this is understandable ;-)
Last updated: 2023-12-11
Post by dkugler on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
the magic option is named "Use CurrentVisu variable" activate this option in the Visualization Manager an have a look: https://help.codesys.com/webapp/_visu_obj_manager;product=core_visualization;version=3.5.14.0 if your button is pressed, "feed" the string varable VisuElems.CurrentVisu := 'visu1'; with the correct name of the depending visu. alternative: place a frame element at a empty main visu, konfigure all visus to be shown by this frame. With setting the switching variable of the frame to the index value of the depending visu, it will switch to it. Advantage: the visu names are not hardcoded as string in the ladder lodgic. Good luck! Hint: If you have multiple VisuClients(Target, WebVisu,...) all will show the same visu. Independent switching is much more difficult, but there is a example from codesys.
Last updated: 2024-02-13
Post by nano on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
this is not easily. From Point of SL-Licenses Codesys didnt provide the informations how to do. We created an own CDS-Component for that Behaviour. This Informations are available for OEM, if you are an OEM you can find the Informations in the RTS-Documentation.
Last updated: 2024-06-14
Post by thedertom on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
Hi I try to get korean texts out of a textlist. For that I want to use DynamicTextGetTextW, but I am a little confused how it is supposed to work. The function returns POINTER TO STRING, but how do I get WSTRING? I succesfully used DynamicTextGetText with classical Strings. Thanks in advance!
Last updated: 2024-09-02
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi, thanks for the link. Maybe I create elements in incorrect way. I always use Interface Editor to create variables which are used inside element (see pics). After that I place element in my visu and use Reference property to link variable or set the value. In that case the value of string is not transferred to general text list for translation as I mentioned before. Do I have to all properties which influence behavior of my element create in Frame configuration instead? What´s the difference to the Interface editor? Thanks a lot. M.
Last updated: 2024-01-02
Post by installwhat on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_operator_string_to/ Something like this?
Last updated: 2024-06-13
Post by installwhat on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_operator_string_to/ Something like this?
Last updated: 2024-06-13
Post by vladimirsmall on Send data to USB
CODESYS Forge
talk
(Post)
Hello/ Need send some file ( for example Array of string) to USB. Which library need used for this. Thank you
Last updated: 2024-07-20
Post by ph0010421 on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
My guess is that's a STRING, not an INT type. And it's 128 bytes, not bits
Last updated: 2024-09-23
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01
Post by russmann on Bitmap image in the codesys visualization doesn't show up in web visu
CODESYS Forge
talk
(Post)
Bitmap Image (outlined in Red in attachment) with it’s configure window open in Codesys 2.3.9.55. Image doesn’t show-up in on-line Web Visu (this project only). No problem with bitmap images in all other codesys 2.3 projects. Web visu in Internet Explorer since 2.3 Web visualizations don't work in Edge.
Last updated: 2024-11-12
Transparency of element rectangle works only in simulation not in WebVisu
CODESYS Forge
talk
(Thread)
Transparency of element rectangle works only in simulation not in WebVisu
Last updated: 2023-05-25
Can "Best Fit in Online Mode" be used in Visualization CE
CODESYS Forge
talk
(Thread)
Can "Best Fit in Online Mode" be used in Visualization CE
Last updated: 2012-05-31
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.