Post by eschwellinger on Raspberry Pi Control SL MC - Restoring License not working anymore!
CODESYS Forge
talk
(Post)
you need to use 'my question ' in the CODESYS store
Last updated: 2023-08-24
Post by gregor on PFC 200 - codesys V3.5
CODESYS Forge
talk
(Post)
As far as I know, only if someone downloaded sourcecode to the PLC.
Last updated: 2023-08-25
Post by eschwellinger on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Post)
I've send out a workaround for this.. Best Regards Edwin
Last updated: 2023-08-26
Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
Hello, Can we please have some details about the error : INVALID_HANDLE? So we can try to avoid it.
Last updated: 2023-08-28
Post by eschwellinger on v3.5 SP19 - Modbus TCP Devices - Channel Limit?
CODESYS Forge
talk
(Post)
Guess you could just add two modbus slaves with the same ip, to enlarge the 10 channel limit.
Last updated: 2023-08-28
Post by eschwellinger on new feature: list/view plclogs from the plcs
CODESYS Forge
talk
(Post)
Since 1.31.0.0 version there is this really helpful feature to browse the plclogs remote via CODESYS Automation server:
Last updated: 2023-08-30
Post by jegerjon on VPN
CODESYS Forge
talk
(Post)
Hi, witch VPN provider for remote PLC Acess do you use/recomend? Preferedbly one where you can Grant certain users acess to specific controllers.
Last updated: 2023-09-06
Post by jegerjon on VPN
CODESYS Forge
talk
(Post)
Hi, witch VPN provider for remote PLC Acess do you use/recomend? Preferedbly one where you can Grant certain users acess to specific controllers.
Last updated: 2023-09-06
Post by jegerjon on VPN
CODESYS Forge
talk
(Post)
Hi, witch VPN provider for remote PLC Acess do you use/recomend? Preferedbly one where you can Grant certain users acess to specific controllers.
Last updated: 2023-09-06
Post by jari-koivuluoma on JSON_Utilities_SL JSONFileWriter error NULL_POINTER
CODESYS Forge
talk
(Post)
FB jsonFileWriter gives a NULL_POINTER error, why? JSONByteArrayWriter works fine so the JSONData FB should be fine. The device is CODESYS Control Win V3 x64 in simulation mode. Codesys version is V3.5 SP16 Patch 5 JSON_Utilities_SL version is 1.3.0.0 Src: ST_TestStruct1a; TXT: WSTRING(10000); MakeJSON : BOOL := TRUE; SrcJSONData: JSON.JSONData; jsonFileWriter : JSON.JSONFileWriter; IF MakeJSON THEN MakeJSON := FALSE; // Struct data to JSONData FB F_TestStructToJSON(ADR(Src),ADR(SrcJSONData)); // Writing to file jsonFileWriter( xExecute := TRUE, sFileName := 'c:\JSONTEST\JSON.txt', eEncoding := JSON.Encoding.UTF_16, xAsyncMode := TRUE, jsonData := SrcJSONData ); // Waiting to finish WHILE jsonFileWriter.xBusy DO ; END_WHILE // To text jsonArrayWriter( xExecute := TRUE, pwData := ADR(TXT), udiSize := SIZEOF(TXT), jsonData := SrcJSONData, xAsyncMode := FALSE, ); END_IF
Last updated: 2023-09-08
Post by transmin01 on EL6751 Canopen_Manager issue
CODESYS Forge
talk
(Post)
Fixed, in the end it just required the target to be rebooted. DOH! Regards Trevor
Last updated: 2023-09-12
Post by timvh on Get the numer of day
CODESYS Forge
talk
(Post)
For a demo application related to date/time, see: https://forge.codesys.com/prj/codesys-example/date-and-time/home/Home/
Last updated: 2023-09-14
Post by eschwellinger on EtherCat Master cannot open network adaptor on Win10x64 target
CODESYS Forge
talk
(Post)
you need to have either Winpcap (versions < CODESYS 3.5.19.0) or Npcap installed
Last updated: 2023-09-20
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
After loading, it seems to be quite responsive. It's just the initial loading that is taking a long time.
Last updated: 2023-09-21
Post by hki75 on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
mmm.. I moved my file to /var/opt/codesys/PlcLogic directory but I still getting FILE_OPERATION_DENIED.. Did I miss something? file rights are 0755
Last updated: 2023-09-27
Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
Okay, i've extendet ist from 6000 to 20000, but the error is still present :-(
Last updated: 2023-09-28
Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection
CODESYS Forge
talk
(Post)
Im running again. I did a firmware update and Runtime update -> PFC200 is online again Thank you very much
Last updated: 2023-09-28
Post by eschwellinger on The required device description is not installed..
CODESYS Forge
talk
(Post)
just rightclick to the second J1939 device in the devicetree and 'update device'
Last updated: 2023-10-03
Post by masmith1553 on Focus/Selection color frame around the element
CODESYS Forge
talk
(Post)
Is there a way to control what element is in focus?
Last updated: 2023-10-27
Post by helcioburd on When using the Element Collections library, is there a proper way to remove a dynamically created collection from memory?
CODESYS Forge
talk
(Post)
I am having exactly the same question...
Last updated: 2023-10-31
Post by dhumphries on install codesys runtime on linux
CODESYS Forge
talk
(Post)
Adding the command worked. I was able to deploy the runtime on an ubuntu server installation. Thanks!
Last updated: 2023-11-04
Post by macros8 on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi, I haven´t noticed you put the comment here. I thing it´s a bit different. What I want is to have detail errors of technology in data type e.g. INT. This variable I would latch to the corresponding error msg but I would like to get it convert to text from the text list and not keep it in INT form. Example. Main error Valve Error: SubErrors 1 - Both sensors 2 - Not retracted in time 3 - Not pulled out in time In HMI Main error + latch SubErrors => "Valve Error: Both sensors" The benefit is that text lists are part of translation and can be easily manipulated. I know I can create whole string msg in PLC but then, it lose advantage of Alarm management. Thanks. M.
Last updated: 2023-11-07
Post by imdatatas on Detecting if a client is connected to webvisu server
CODESYS Forge
talk
(Post)
Thank you @dgirard Your idea and above description helped me what i was looking for.
Last updated: 2023-11-08
Post by vformanek on Datasource OPC UA Client error ID:7012
CODESYS Forge
talk
(Post)
Sorry to bother but what do you mean by target ?
Last updated: 2023-11-21
Post by tomgr on Codesys 3.5.19 Control Win x64 - network adapter for EtherCAT master not working
CODESYS Forge
talk
(Post)
Hi guys I am trying to run on my laptop Codesys 3.5.19 Control Win x64 where I created a EtherCAT master. I have defined the controler, specified network adapter (my docking station) and everything worked as expected. Later I needed to test it on site (without docking station) so I changed the network adapter by EC master to my laptop network card. After that it shows "Network adapter opened" but no device can be found by scanning and in LOG is saying "SysEthernet: packet could not be sent, error code: -1". Same error with USB network card, but if I switch back to docking station, all is working again... Any idea what I'm doing wrong?
Last updated: 2023-11-22
To search for an exact phrase, put it in quotes. Example: "getting started docs"