is there a way to convert pointer to interface reference
CODESYS Forge
talk
(Thread)
is there a way to convert pointer to interface reference
Last updated: 2018-11-14
Lookup Symbol Name from pointer address?
CODESYS Forge
talk
(Thread)
Lookup Symbol Name from pointer address?
Last updated: 2012-10-04
fun-pointer mit SysIECGetFctPointer(INDEXOF(fun)) wie aufruf
CODESYS Forge
talk
(Thread)
fun-pointer mit SysIECGetFctPointer(INDEXOF(fun)) wie aufruf
Last updated: 2007-11-22
C0032 Error to type Pointer to IoConfigParameter
CODESYS Forge
talk
(Thread)
C0032 Error to type Pointer to IoConfigParameter
Last updated: 2024-03-25
Cannot convert type 'Unknown type: 'ADR(tabOrderIdArray)" to type 'POINTER TO ARRAY [0..0]OF INT'
CODESYS Forge
talk
(Thread)
Cannot convert type 'Unknown type: 'ADR(tabOrderIdArray)" to type 'POINTER TO ARRAY [0..0]OF INT'
Last updated: 2021-04-26
<identifier>: POINTER TO <data type | function block | program | method | function>;
CODESYS Forge
talk
(Thread)
<identifier>: POINTER TO <data type="" |="" function="" block="" program="" method="">;</data></identifier>
Last updated: 2022-03-23
how to execute a pointer to a function or a function block?
CODESYS Forge
talk
(Thread)
how to execute a pointer to a function or a function block?
Last updated: 2017-04-04
Wie kann ich einen Pointer to ULINT in eine variable Struktur verwandeln?
CODESYS Forge
talk
(Thread)
Wie kann ich einen Pointer to ULINT in eine variable Struktur verwandeln?
Last updated: 2021-11-23
Post by simotion on Pointer to Softmotion axis
CODESYS Forge
talk
(Post)
No ideas?
Last updated: 2023-10-27
Post by trusty-squire on CNC - How to manipulate SMC_GeoInfo objects
CODESYS Forge
talk
(Post)
Sometimes you just need to pose a question on a forum and re-read it to get clarity. pGeoInfo := SMC_GetObj(poq:=ADR(fbCncInterpreter.poqDataOut), n:=1); This won't work, I'm providing a pointer to a pointer, as poqDataOut is already a pointer! I just need to remove the ADR() and it works. pGeoInfo := SMC_GetObj(poq:=fbCncInterpreter.poqDataOut, n:=1);
Last updated: 2024-07-26
Post by totorovic on Pointer to Softmotion axis
CODESYS Forge
talk
(Post)
I get the same warning message with initialized variable. Codesys 3.5.19.20
Last updated: 2023-11-09
Post by timvh on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
First of all you need to enable "Use unicodestrings" in the Visualization Manager. This function returns a pointer to a WSTRING (not STRING). To get this wstring value, do something like this: VAR myWstringVariable : WSTRING(255); END_VAR myWstringVariable := myResult^; // this is dereferencing the pointer to the WSTRING.
Last updated: 2024-09-03
Post by tk096 on Pointer to Softmotion axis
CODESYS Forge
talk
(Post)
Hi, you can take a look at https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_global_init_slot.html Maybe it helps.
Last updated: 2023-11-23
Post by tvm on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
It will be a reference, because it's a VAR_IN_OUT. it's a little weird debugging the array online. It just shows as a POINTER TO INT, and you can't actually see the array from the function side. But you can still work with it as a normal array, not a pointer.
Last updated: 2024-01-09
Post by csu-chris on No file found
CODESYS Forge
talk
(Post)
I'm having trouble getting started with the SysFile library. I tried copying and running the code found here: https://forge.codesys.com/forge/talk/Engineering/thread/f17c3d0e64/ Every time I try to run the file handle pointer returns: 16#FFFFFFFFFFFFFFFF <dereference of="" invalid="" pointer=""></dereference> I can see the file when I look in the Device -> Files window Any idea what I'm doing wrong?
Last updated: 2024-10-15
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Hi, Communication with the ADS1115 is actually simple. 1. write config 2. write address pointer 3. read conversation register The ADS1115 works like a multiplexer. This means that you do this individually for each channel that you want to read. e.g: Channel 1: write config > write address pointer > read conversation register Channel 2: write config > write address pointer > read conversation register Channel 3: write config > write address pointer > read conversation register Channel 4: write config > write address pointer > read conversation register then you start again from the beginning You can also omit individual channels or read only one. It doesn't matter. I have written the driver so that I can also use it on the TCA9548. The driver is from Stefan Dreyer. In your case, the driver works and communication with the ADS1115 is running. As you can see, the cfgWrong:=FALSE If you could not write or read data, cfgWrong:=TRUE; This means that either something is wrong with your ADS1115 or you have connected something incorrectly. Question: what voltage do you want to measure?
Last updated: 2024-11-08
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
I use the function SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_WRITE, pErrorFileOpen); to open and write a file. Since the update from Codesys V3.5 SP17 to V3.5 SP19 Patch 5 it does not work anymore. I first had SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_APPEND_PLUS, pErrorFileOpen); in both versions. hFile_Test is a pointer to byte. It gives an exceptional error when dereferencing the hFile_Test pointer. Edit: I use Codesys on a Raspberry pi
Last updated: 2024-02-19
Post by remcoborghuis on C0032 Error to type Pointer to IoConfigParameter
CODESYS Forge
talk
(Post)
Hi All, I'm using codesys on a raspberry PI. I use V3.5 SP18 Patch 2 development system and codesys for raspberry pi 4.8.0.0. Sometimes when I build the project I get error messages C0007: Expression expected instead of ',' and C0032: Cannot convert type 'Unknow type: '!!!'ERROR'!!!" to type 'POINTER TO IoConfigParameter'. I can't click on the message to bring me to the fault. After I do a "Clean all" the build finishes successful. Anyone who can help me with this problem? Thanks! Remco Borghuis
Last updated: 2024-03-25
Post by sedoerr on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
FUNCTION CheckDialogOpen : BOOL VAR_INPUT sDialogName : STRING; END_VAR VAR pstClientData : POINTER TO VisuElems.VisuStructClientData; itfDialogManager : VisuElems.IDialogManager; itfMyDialog : VisuElems.IVisualisationDialog; END_VAR VisuElems.g_ClientManager.BeginIteration(); WHILE (pstClientData := VisuElems.VisuElemBase.g_ClientManager.GetNextClient()) <> 0 DO itfDialogManager := VisuElems.g_VisuManager.GetDialogManager(); itfMyDialog := itfDialogManager.GetDialog(sDialogName); CheckDialogOpen := VisuDialogs.VisuDlgUtil_IsDialogOpen(itfMyDialog,pstClientData,itfDialogManager); IF CheckDialogOpen THEN EXIT; END_IF END_WHILE
Last updated: 2023-09-26
Post by reinier-geers on Pointer Axis
CODESYS Forge
talk
(Post)
I want to make a FB of MC. But i need a variable for Axis. How do i have to declare that ? ptAxe : AXIS_Ref_SM3; //:= SM_Drive_ETC_Delta_ASDA_A2 ; this is somehowe a problem
Last updated: 2024-01-12
Post by reinier-geers on Axis declare
CODESYS Forge
talk
(Post)
In motioncontrol every block start with Axis. How can i make a variable to make my own FB ? Somthink like : _Axe : pointer to Axis_Ref_MC := Axis_1 ;
Last updated: 2024-02-13
Post by dtamm on How to read string from CharBufferPtr?
CODESYS Forge
talk
(Post)
Solved it! The simple answer was to declare a variable as POINTER TO STRING and assign the GetMessage result to that variable. Then, the ^ operator can be used to extract the message as string.
Last updated: 2024-02-21
Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06
Post by abrarsk on SysCom Library Usage
CODESYS Forge
talk
(Post)
Update: I was able to successfully use the SysCom.lib. I had to install SysTypes2Interface library as well and wrote following code. Declaration hCom : RTS_IEC_HANDLE; pResult : POINTER TO RTS_IEC_RESULT; Implementation hCom := SysComOpen(ComSettings.sPort, ADR(pResult));
Last updated: 2024-08-10
Post by dkugler on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
is your pointer set to the correct visu client? set a breakpoint in your client iteration and step through the active visu clients like programming system, targetvisu, webvisu,... and check the last usage value of each client
Last updated: 2024-08-30
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.