Post by k4zz on Scripting static code analysis
CODESYS Forge
talk
(Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18
Post by gauravthelkar on Static Code Analysis
CODESYS Forge
talk
(Post)
Can you please help on my query below?
Last updated: 2024-08-06
Post by snhatton on How to switch between dynamic IP address and dynamic?
CODESYS Forge
talk
(Post)
Does this help: https://pimylifeup.com/raspberry-pi-static-ip-address/#:~:text=1%20To%20begin%20setting%20up%20a%20static%20IP,go%20ahead%20and%20restart%20the%20Raspberry%20Pi.%20. Following those instructions, it is possible to configure the ip address as static.
Last updated: 2023-11-08
Post by fleaplc on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
/var/opt/codesys/PlcLogic not work here, again FILE_OPERATION_DENIED. May I simply moved my files in /var/opt/codesys/PlcLogic or need some particular settings?
Last updated: 2023-09-30
Can't get the IEC var address correcttly when using the function "IecVarAccGetAddress 2"
CODESYS Forge
talk
(Thread)
Can't get the IEC var address correcttly when using the function "IecVarAccGetAddress 2"
Last updated: 2018-12-25
Execute View Model Function block that is declared in the visualation interface as a VAR?
CODESYS Forge
talk
(Thread)
Execute View Model Function block that is declared in the visualation interface as a VAR?
Last updated: 2022-07-15
PFC200 unresponsive with loads of messages in /var/log/wago/wagolog.log
CODESYS Forge
talk
(Thread)
PFC200 unresponsive with loads of messages in /var/log/wago/wagolog.log
Last updated: 2022-04-14
Post by eschwellinger on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
due security reason files could only be accessed in /var/opt/codesys/PlcLogic directory
Last updated: 2023-09-25
Post by eschwellinger on Loosing connection to emulation running on Linux
CODESYS Forge
talk
(Post)
check the plc log /var/opt/codesys/codesyscontrol.log
Last updated: 2024-09-19
Post by k4zz on Continuous Build Server
CODESYS Forge
talk
(Post)
Hallo Martin, Thank you so much for the Code example. It works really fine for .porject Types. However, I encountered a challenge when attempting to apply it to .library Types. I also tried the option to "Perform static analysis automatically after compilation" # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() Could you please offer any insights into why this might be occurring?
Last updated: 2024-03-15
Post by mubeta on STRUCT AT %MW1000
CODESYS Forge
talk
(Post)
This is normal and correct since in CoDeSys static addressing of variables uses the IEC method. A LONG tag has the size of 8 bytes, so %ML0 coincides with %MB0 ... %MB7; %ML1000 with %MB8000 ... %MB8007. (Similar reason for word and other formats). Also the reason the compiler won't let you map the structure to a %MW depends on the fact that the individual base elements are manipulated to 64 bits regardless of the smaller size. That said, it makes me strange that you cannot write a parser without making use of static memory allocation.
Last updated: 2024-08-13
Post by enricoghisla on Functional block
CODESYS Forge
talk
(Post)
Good morning, i have a problem with an FB, i create VAR inside the block but outside i can't reach them, i can reach only IN/OUT/IN-OUT VAR, do you know which could be the problem? Regard
Last updated: 2024-04-16
Post by ljg007 on Variable assignments
CODESYS Forge
talk
(Post)
That is an output of the Function Block ModbusMasterRTU example: xIsConnected=> xIsConnected In this line the VAR ModbusMasterRTU.xIsConnected is written to VAR xIsConnected xError=> is writing to nothing here.
Last updated: 2024-07-22
Post by andrax on Stop Programm geladen Ausnahmefehler
CODESYS Forge
talk
(Post)
Also, ich habe jetzt mit Static Analysis Light einige Fehler behoben. Aktuell steht nur ein Fehler im Logbuch: "Retain restore from file failed" Sobald ich wieder diesen Absturz erlebe, melde ich mich wieder.
Last updated: 2024-01-15
Post by eschwellinger on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
we need plclog cat /tmp/codesyscontrol.log or cat /var/codesys/codesyscontrol.log depend on which runtime version you use for the error situation
Last updated: 2023-09-26
Post by hki75 on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
mmm.. I moved my file to /var/opt/codesys/PlcLogic directory but I still getting FILE_OPERATION_DENIED.. Did I miss something? file rights are 0755
Last updated: 2023-09-27
Post by i-campbell on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
in your project, to access /var/opt/codesys/PlcLogic/my.file, use the string 'my.file' or '$$PlcLogic$$/my.file'
Last updated: 2023-10-17
Post by eschwellinger on Save Recipe on Paspberry
CODESYS Forge
talk
(Post)
permissions, since a security related change it is not allowed to save files outside of the Plclogic directory. Use /var/opt/codesys/Plclogic/
Last updated: 2023-12-29
Post by eschwellinger on PFC100 Licensing fails
CODESYS Forge
talk
(Post)
possible to use a newer version? maybe it is /var/opt/codesys/cmact_license in your version
Last updated: 2024-03-19
Post by smartcoco on Release SP20 - Changes in behaviour?
CODESYS Forge
talk
(Post)
You should use this method: VAR NULL:REFERENCE TO FB_MSG END_VAR Add_EVT_OUT REF= NULL;
Last updated: 2024-03-25
Post by sean-barton on FILE_OPERATION_DENIED
CODESYS Forge
talk
(Post)
I have code written since version 3.5.16 to access the USB drive, how can I do that now the file access has been taken away? I have tried adding a sybolic link to the usb drive in the following directories: /var/opt/codesys/PlcLogic/ /var/opt/CODESYS/PlcLogic/ /opt/CODESYS/PlcLogic/ I still recieve a "FILE_OPERATION_DENIED" response when accessing the USB drive.
Last updated: 2023-10-13
Post by eschwellinger on Correct CAN Driver for EL6751
CODESYS Forge
talk
(Post)
Hi, for Control Win : add CmpEL6751CanDrv in the c:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE\CODESYSControl.cfg [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=CmpEL6751CanDrv for Linux SL or Pi or any ARM device - I think it is already static loaded as component - see plclogger on startup
Last updated: 2023-09-20
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07
Post by wiresplus on Cannot get INT_TO_TIME working
CODESYS Forge
talk
(Post)
Hello, I have a simple TON timer. It is watching prime loss for a pump. The operator can set the delay via the HMI, it is an integer (seconds) As the TON uses milliseconds, we then multiply the entry by 1000 to get seconds. Seems simple, but... VAR PrimeTimer : TON; primetime : INT; END_VAR PrimeTimer(in:=State>0 AND FlowRate<MinimumFlow,pt:=INT_TO_TIME(primetime *1000)); For an entered 15 seconds (VAR primetime:=15;) the timer reads 49d17h2m26s760ms !!!! What am I doing wrong?
Last updated: 2024-01-26
Post by wollvieh on License Activation Problems
CODESYS Forge
talk
(Post)
on a raspberry pi delete the folder and its content before licensing. /var/opt/codesys/cmactlicense If you plug this SD card in another raspi ( which has another hw-serial number) you'll get a second empty softcontainer. This could lead to an unlicensed PFC (it could only handle one container) The solution is: To delete the /var/opt/codesys/cmactlicense directory and content of it and then aktivate the lizenz via WibuCmRau file and Lizenzmanager.
Last updated: 2024-06-24
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.