Post by atef on CODESYS V3.5 SP19.7 on windows server Installing error CODESYS Forge talk (Post)
Hi, while installing CODESYS V3.5 SP19.7 on windows server 2022 standard 21H2 I got error 2732 directory manager not initialized Has anyone faced this problem before or found a solution? Any guidance would be greatly appreciated. Thanks in advance!
Last updated: 2025-08-04

CODESYS V3.5 SP19.7 on windows server Installing error CODESYS Forge talk (Thread)
CODESYS V3.5 SP19.7 on windows server Installing error
Last updated: 2025-08-04

Codesys Control for RPi and Waveshare AD/DA hat CODESYS Forge talk (Thread)
Codesys Control for RPi and Waveshare AD/DA hat
Last updated: 2025-08-04

Post by llewv123 on Bullseye and Waveshare 2-CH CAN FD HAT rev2.1 with two slaves CODESYS Forge talk (Post)
Hi David, I am trying to use a Waveshare AD/DA hat for RPi in CodeSYS control for RPi, and have no idea as to where to start. Perhpas you've cracked this above? Any help appreciated!
Last updated: 2025-08-04

Post by llewv123 on Codesys Control for RPi and Waveshare AD/DA hat CODESYS Forge talk (Post)
Good day, I am attempting to use a Waveshare AD/DA precision HAT with RPi 4B+, using Codesys Control for Rpi. The waveshare hat uses SPI. I am successfully using the RPi GPIO (inputs and outputs) but do not know how to access the AD/DA channels. Any help would be appreciated.
Last updated: 2025-08-04

Post by clarenced on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks CODESYS Forge talk (Post)
Using codesys v3.5 SP21 Patch 1. We are using Visualization to display alarms. Other then the automatically created AlarmManagerTask, there is no code written to call AlarmStorage_Prg. Any ideas why we would be seeing this error in the log? The runtime actually shutdown. Not sure if that was caused by this error or not. 2025-08-03T02:45:35.444Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T03:48:15.294Z, 0x00001012, 4, 0, 0, * ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks. 2025-08-03T04:38:11.557Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! * 2025-08-03T04:38:11.576Z, 0x0000010f, 8, 1, 0, #### Exception: SysSemEnter - Semaphore deadlock detected - owner thread died [tid:726740] - system may be in an inconsistent state. 2025-08-03T04:38:11.576Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-08-03T04:38:11.576Z, 0x00000001, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-08-03T04:40:12.308Z, 0x00000001, 1, 0, 35, CODESYS Control shutdown... 2025-08-03T04:40:13.436Z, 0x00000071, 1, 0, 13, Webserver stopped 2025-08-03T04:40:13.437Z, 0x00000114, 2, 1, 0, !!!! Warning: task_signalhandler_exit [MainTask] lost cycles: 14809 2025-08-03T04:40:13.497Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IecVarAccess</cmp>, <id>0x00001007</id> <ver>3.5.3.64</ver> 2025-08-03T04:40:13.506Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>AlarmMgr</cmp>, <id>0x00001012</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.513Z, 0x00000071, 2, 0, 14, !!!! Warning: Unbalanced calls to WebServerRequestRunning/WebServerReleaseRunning 2025-08-03T04:40:13.513Z, 0x00000001, 1, 0, 10, [UNLOADED] IEC|Dynamic: <cmp>IECVisualization</cmp>, <id>0x0000100c</id> <ver>4.7.0.0</ver> 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:40:13.611Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051500) unregisterd at the OPC UA server. 2025-08-03T04:50:17.708Z, 0x00000001, 1, 0, 36, CODESYS Control shutdown done
Last updated: 2025-08-04

MODBUS CODESYS Forge talk (Thread)
MODBUS
Last updated: 2025-08-05

Post by ivan-g on MODBUS CODESYS Forge talk (Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a Facebook post that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05

Post by ivan-g on MODBUS CODESYS Forge talk (Post)
Hi There, I took over a project from a colleague (in GTB) who left the company. When I took over his project, it wouldn't compile because some libraries were missing. I managed to recover quite a few libraries, but I can't find the library that contains the block functions shown in the image. Here are a few examples: Fb_RegMel_ISO Fb_DefModbus FbDecalConsSalSO Fb_Autor_FreeCool_CTA_C I'm a little stuck at the moment, so if you see a FB that speaks to you, don't hesitate to get in touch! Thank you in advance for your help.
Last updated: 2025-08-05

MODBUS CODESYS Forge talk (Thread)
MODBUS
Last updated: 2025-08-05

Post by micik on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore CODESYS Forge talk (Post)
I have a test application and use Codesys Control for Rasp Pi SL. I made a mistake and updated device from MSL to MC SL, and now if I try to go online with archived version of the project I gett error message that IDs are different between project device and target device. Of course, I can go online if I changed device in the project from SL to MC SL, but I'm not sure that is correct. So I have two questions: 1. What is the actual difference between MC SL device and standard SL device when it comes to raspberry pi 4? 2. What change I need to do on raspberry pi4 side to change device back from MC SL to SL? Thank you!
Last updated: 2025-08-05

Post by arwie on Bullseye and Waveshare 2-CH CAN FD HAT rev2.1 with two slaves CODESYS Forge talk (Post)
Maybe this can help: https://www.youtube.com/watch?v=NgsJr0hds4k
Last updated: 2025-08-05

Bullseye and Waveshare 2-CH CAN FD HAT rev2.1 with two slaves CODESYS Forge talk (Thread)
Bullseye and Waveshare 2-CH CAN FD HAT rev2.1 with two slaves
Last updated: 2025-08-05

Post by r0udy on Adress problem CODESYS Forge talk (Post)
Hi, I 've just started a new project. Translating SoMachine (SCHNEIDER) to CODESYS 3.5.18//DEMO (EATON XC303) I succeed (I think so) to copy FB, STRUCT,... and I also integrated old library. When I build F11, I have a first problem : - Adress out of rang - Overlay It's strange, usually %ML100 > %MB800 Here ONLINE: %ML100 > %MB100 !! I don't understand why ? And idea ? Thanks
Last updated: 2025-08-06

Post by eschwellinger on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore CODESYS Forge talk (Post)
1) https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html -> SL: Restrictions The combination of Raspberry Pi and a CODESYS Runtime is for private use, test and teaching purposes. Commercial use is not permitted. 2) you could switch between them by /etc/codesyscontrol/CODESYSControl_User.cfg [CmpRasPi] Architecture=armv7l for MC: armv7l for SC: armv6l for 64Bit: aarch64 or in the Deploytool:
Last updated: 2025-08-06

Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore CODESYS Forge talk (Thread)
Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore
Last updated: 2025-08-06

Post by eschwellinger on Codesys Virtual control SL CODESYS Forge talk (Post)
Hi, which CODESYS Version are you using exactly? Either update to 3.5.21.x if you are on 3.5.20.x if not - add a more secure pw. Seems that on adding the login credentials it is mandatory in 4.16.0.0 -to have complianct to password policy seems a bug that the message not occure.
Last updated: 2025-08-06

Post by dkugler on Visualization Scaling the Keypad CODESYS Forge talk (Post)
I think this thread will guide you the way. Google translate will be your friend :-) https://forge.codesys.com/forge/talk/Deutsch/thread/7bb078f11f/#5d58/4633
Last updated: 2025-08-06

Visualization Scaling the Keypad CODESYS Forge talk (Thread)
Visualization Scaling the Keypad
Last updated: 2025-08-06

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Hi, Thank you for your reply. 1. Codesys IDE version is it showing 3.5 SP 20. please check the attachment. 2. Codesys Virtual control for SL -- version is 4.16
Last updated: 2025-08-07

Post by gepert on GearInPos CODESYS Forge talk (Post)
Hello, Please give any tips regarding stopping Mc_GearInPos block. Please look at attached drawings. When fb MC_GearInPos is started, output "busy" is true - it is ok. But when i want to stop this funkction blok i deactive execute input and i use Mc_stop. Unfortunelly Mc_gearInPos is still busy. It lasts till to synchronize phase. Then i can stop it by Mc_stop. So I cannot stop fb before synchrnization. Can you give any tips how solve this problem. Sometimes I must to switch off before synchro. Best regards Lukasz
Last updated: 2025-08-07

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Please reply back.
Last updated: 2025-08-07

Post by eschwellinger on Codesys Virtual control SL CODESYS Forge talk (Post)
I would just use latest CODESYS Version, this will solve it.
Last updated: 2025-08-07

Post by williamjmak1 on Current Visu name without Current Visu Variable CODESYS Forge talk (Post)
Hello everyone, I was just wondering if anybody knows if there's a way to pull the string name of the current visualization without using the current visu variable. I'm working on a project where we don't want web clients to change the current visualization on the HMI of the machine. Thanks!!
Last updated: 2025-08-07

Post by kumareasu on Cursor to move to a control CODESYS Forge talk (Post)
How to move cursor to a particular control in HMI through PLC program to enter data from keyboard without using tocuhscreen or mouse
Last updated: 2025-08-08