Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
It's already there, the service get started as default. I missed to say that sometimes it happens w/o even the system get restarted. Anyway, the main issue here is to know the state of the runtime. We collect a lot of informations about the whole system, and it would be nice to have a way to detect the runtime state.
Last updated: 2024-07-02

Post by timvh on No source code available for this object CODESYS Forge talk (Post)
The message means that you (CODESYS) tries to open the function block, but this is not possible because the library which contains the FB is compiled. You either get this when you try to manually open the function block (while editing the application), but it could also happen that an exception occurs in the running application and CODESYS tries to show the location where it occured. If it happened in an FB of the compiled library, it cannot show this and you could get this message too.
Last updated: 2024-07-16

Post by gatto on Read codesys version in the codesys application CODESYS Forge talk (Post)
hi, i used another way declaration: pApp : POINTER TO APPLICATION; pAppInfo : POINTER TO APPLICATION_INFO; ProjectName : STRING (24) ; CodesysVersion : STRING (15) ; code: //library : // CmpApp // IoDrvEthernet // // Get Pointer to current application pApp := CmpApp.AppGetCurrent( pResult:= 0 ); // Get Pointer to Application information pAppInfo := CmpApp.AppGetApplicationInfo(pApp:= pApp, pResult:= 0 ); ProjectName := pAppInfo^.pstProjectName^ ; //convert codesys version to string CodesysVersion := IoDrvEthernet.UDINT_TO_IPSTRING ( udiIPAddress := pApp^.udiPSVersion ) ; so i think you need to convert your dwVersion in a UDINT and after convert UDINT_TO_IPSTRING
Last updated: 2025-01-17

Post by ph0010421 on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
hi all I have a FB with IN/OUT variable. Inside the FB, I want to get the address of the IN/OUT variable. If I use __SYSTEM.VAR_INFO, I get the address of the FB copy rather than 'external' variable. VAR_IN_OUT MyVar: bool; END_VAR VAR Info: __SYSTEM.VAR_INFO; END_VAR Info := __VARINFO(MyVar); This give me the address of MyVar but I actually want the address of the variable passed to MyVar Any clues please?? thanks, ph
Last updated: 2025-01-24

Post by glutenaron on Safety drive EL6900 and mitsubishi CODESYS Forge talk (Post)
Hi, Im wokring to get my servo mitsubishi mr-j5-g40-rnj1 working with my safety drive. I have as you can se in the picture Ek1100 koppler and EL6900 as safety plc. My questien is how do i connect the safety_drive to the SM3_Drive_ETC_Mitsubishi_MelServo_J5_Axis1 down below? I get the error ((Logical I/Os]: The logical device 'Safety_Drive' is not mapped to any physical device.)) but how do i map this? regard
Last updated: 2025-05-13

Post by nz-dave on Custom library, ethernet/ip adaptor CODESYS Forge talk (Post)
Im Putting alot of my custom functions blocks into a library I have a EthernetIP VSD FB that i would like to get Status from the adaptor. EthernetIP_remote_adaptor.estate is one what i want to get. so anyone know how to point that to my function block? when i use the block i just want to have an input "Drive" that would point to the adaptor. like in softmotion when you just put the axis name in the FB to point the FB to a certain axis. Hope that makes sense, cheers
Last updated: 2025-05-21

Post by mputaggio on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
Hello, We encountered the same issues on both recipe library versions 4.2.0.0 and the newest 4.3.0.0. The Arrays of structs get saved correctly but loading them restores only some indexes, while others get lost or completely wrong. We have been using the same recipes for the last two years on recipe manager vers. 3.5.17 withoud issues. There also seems to be a different behaviour in vers. 4.3.0.0 but it's still incorrectly loading the recipes. Did you find any workaround or solution? Codesys version used: 3.5.19.50
Last updated: 2023-12-15

Post by androidzz on Json Builder problem? CODESYS Forge talk (Post)
Dear reader, I am using the codesys JSON utilities SL, 1.9.0.0 library. And then specifically the FB JSONBuilder. I need to create a main object with at least 2 objects in it. The first object is no problem, but I cannot insert the second object into the main object. See attached my code and the result I get. I am assuming that I am doing something wrong with the parent index but have tried a lot and can't get it done. Kind regards, Rob
Last updated: 2024-03-11

Post by stuartjr on Webvisu IE Page Scroll Bars CODESYS Forge talk (Post)
Is it possible to get scroll bars to show when displaying a web visualization in V2.3? I've got some big pages that I can scroll around when using the in-built visualization but when they are displayed in IE i can't seem to scroll around. All I can do it drag the window bigger onto my other display to get access to the extra area. I've also tried zooming the page out in IE but this doesn't seem to work at all.
Last updated: 2024-03-28

Post by schnepper on Error building Extension SDK Linux code CODESYS Forge talk (Post)
I'm installed the CODESYS Control for Linux SL package and am trying to use the Extension API to call a simple C function. When I get to the step to run "make all" on the Linux machine, I get the error: build interface header: out/CmpFirstTestItf.h from CmpFirstTestItf.m4 ERROR: This functionname does not contain _cext (this is mandatory, see help for details): DEF_API(void',CDECL',external_struct__fb_init',(external_struct_fb_init_struct *p)',1,0x1F77E075,0x00000001) Why does "Generate Runtime System Files" create a function that does not have cext in the name? What am I missing?
Last updated: 2024-04-01

Post by kris-samoy on Get Alarm status in Codesys CODESYS Forge talk (Post)
I am rather new to Codesys and I'm trying to figure out how to get the status of an alarm. This to interlock the start of a device until the alarm has been acknowledged... I am not sure if IAlarm.GetState (METH) can be used for this purpose. If yes then could someone please briefly explain how to use this? https://content.helpme-codesys.com/en/libs/AlarmManager/4.1.0.0/Interfaces/pou-IAlarm/GetState.html Thx & grtz, Kris
Last updated: 2024-06-03

Post by mubeta on parker servo and position CODESYS Forge talk (Post)
In general, drives have parameter sets to adjust behaviour in such cases: position recovery, adaptation with resistant torque, out-of-position window failure, etc. (Much depends on the type of configuration set for the axis: positioner, speed controller, torque controller, etc.). I have used that type of drive very little, in only two cases and a long time ago. To tell you what is normal is impossible. I know by reputation they are very simple objects, without too many pretensions and adjustments possible. Try running traces by monitoring actual position, motor current, torque and following error. These are the most sensible curves to understand what is going on. Maybe by fine tuning the motor tuning, the current controller or the speed controller you will get something closer to what you want. For example, from DS, the motor has a standstill torque of 3 Nm. Observe with traces whether this is effective: motor current trend. And afterwards, when you have your own accurate picture of the situation, you can also hear from the product's local support to see if you can steal a few more things from it performance-wise.
Last updated: 2024-08-05

Post by c3po on Von SNMP auf IIoT wechseln CODESYS Forge talk (Post)
Hallo, 1. ich bin komplett NEU was Codesys angeht 2. ich muss direkt ein Retrofit machen von V2 auf V3 3. Neue Steuerung: WAGO 750-8211 PFC200. 4. das Projekt in V2 hat über SNMP daten im Netzwerk zur Verfügung gestellt, oder diese gelesen 5. das Projekt in V3 kann SNMP nur noch eingeschränkt nutzen, deswegen wurde mir vom WAGO Support nahegelegt die IIoT Lib zu verwenden. Frage: Wie mach ich das? Konkret: Ich habe die WagoAppSNMP Bibliothek installiert, damit kann ich schon mal Set und Get nutzen (hoffentlich, hab es ja noch nicht getestet, sondern nur programmiert). Ist das ein schlauer Weg, das über diese Lib zu machen? Denn: was macht der SNMP_SET_PLCDATA_WRITEAREA ? Den kann ich über die Wago Lib nicht nutzen und weiß auch nicht, was dieser Baustein konkret tut (Bild im Anhang). Es scheint mir, hier werden Daten auf ein Word im Netzwerk geschrieben? Aber geht das nicht auch einfacher? Es ist ja keine Adresse hinterlegt, wo das hin gehen soll oder? Also, ich verstehe den Baustein nicht so ganz und konnte bisher auch keine Erklärung dazu finden. Vielen Dank schon mal für eure Unterstützung, K.
Last updated: 2024-08-19

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by struccc on The future and proper use of CAA.BOLT, CAA.SEMA,.. CODESYS Forge talk (Post)
Dear All, Dear CODESYS, I'm curiously following CODESYS transitioning away from the CAA libraries, and I'm mostly in favor of these major changes. Naturally, I'd like to align my current (not end-user) developments accordingly. I'm tracking , reading release notes, ... And want to figure out the future :) Is it possible to hear / read more about the reasons, objectives and scope of these changes? One important element is CAA Types - CAA Types Extern. What is the plan with that? What's the future of CAA.SEMA, CAA.BOLT ? I have never used them (always relied on SysLib*), but they are tempting... Would be useful to have a platform independent "Macro" for this functionality... Is there something in existing or planned ? Are they suitable to be used in low level libraries... For Example IO-Drivers, Components, "to-become system libraries"? CAA.TaskLock, CAA.TaskUnlock ? Well, they don't claim platform independency, so I can't rely on those.... Any up-to-date advise, standard, pattern to follow in new libraries for task and resource locking? Practical set of conditional defines to be used? If this information is not publicly available, can you please send a private message about the proper way to achieve this? I have support agreement, just couldn't get trough with these questions... P.
Last updated: 2025-03-14

Post by jeroenaero on Problem with CodeSys Control SL Deploy Tool 4.15.0.0 CODESYS Forge talk (Post)
Hello, We just installed the new version of CodeSys Control SL Deploy Tool 4.15.0.0 but we get the following error when we try to add a VPLC. Can someone of the CodeSys team fix this issue? the object reference is not set to an instance of the object Zie het einde van dit bericht voor meer informatie over het aanroepen van JIT-foutopsporing (Just In Time) in plaats van dit dialoogvenster. ** Tekst van uitzondering ** System.NullReferenceException: De objectverwijzing is niet op een exemplaar van een object ingesteld. bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm.ShowAllImages() bij _3S.CoDeSys.RuntimeDeployTool.Views.AddNewInstanceForm..ctor(List1 virtualControls, List1 existingNames) bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.OnAddInstanceClick() bij _3S.CoDeSys.RuntimeDeployTool.Views.MainEditorTab_Operation.bt_add_Click(Object sender, EventArgs e) bij System.Windows.Forms.ToolStripItem.RaiseEvent(Object key, EventArgs e) bij System.Windows.Forms.ToolStripButton.OnClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleClick(EventArgs e) bij System.Windows.Forms.ToolStripItem.HandleMouseUp(MouseEventArgs e) bij System.Windows.Forms.ToolStripItem.FireEventInteractive(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStripItem.FireEvent(EventArgs e, ToolStripItemEventType met) bij System.Windows.Forms.ToolStrip.OnMouseUp(MouseEventArgs mea) bij System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) bij System.Windows.Forms.Control.WndProc(Message& m) bij System.Windows.Forms.ScrollableControl.WndProc(Message& m) bij System.Windows.Forms.ToolStrip.WndProc(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m) bij System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m) bij System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Geladen assembly's ** mscorlib Assembly-versie: 4.0.0.0 Win32-versie: 4.8.9300.0 built by: NET481REL1LAST_C
Last updated: 2025-04-24

Post by laurits on Max lines of code, codesys CNC ? CODESYS Forge talk (Post)
Hi, okay here's the project, it's a modified version of "CNC Example 10: Programming Dynamic CNC Paths", no need for G Code text file (i have also tried with G code text file, same problem) in "PROGRAM PLC_PRG" you can set bStart to true, and the program should start running, go to "PROGRAM CNC" and you can see axis moving. lrXpos := IoConfig_Globals.XAixs.fSetPosition; lrYpos := IoConfig_Globals.YAxis.fSetPosition; Now you can can change the number of movements in the the "PROGRAM PLC_PRG" From this number of movements in "program PLC_PRG" BUF : ARRAY[0..32010] OF SMC_GEOINFO; xp : ARRAY[1..32000] OF REAL; yp : ARRAY[1..32000] OF REAL; to this number to this number of movements BUF : ARRAY[0..132010] OF SMC_GEOINFO; xp : ARRAY[1..132000] OF REAL; yp : ARRAY[1..132000] OF REAL; Now if you start the program again you should see an error in the "sMC_Interpolator: SM3_CNC.SMC_Interpolator;" function block Let me know if you can not get it running.
Last updated: 2025-06-03

Post by axilleas on SMC_Interpolator + SMC_controAxislbyPos CODESYS Forge talk (Post)
dear all I am working on a very generic gantry system (virtual drives + win v3 control) reading gcode from external file. In order to stop the interpolator function from running when gaps are detected, SMC_controlAxisByPos FB has the bStopIpo output which according to the manual is connected to the Interpolator's bEmergencyStop. Lets assume that the axis are parked in position X1000 Y1000 and the initial G code movement is G00 X500 Y500. The normal behavior is to travel from the actual x1000 y1000 to G00 X500 Y500. The SMC_Interpolator always gets the X0 Y0 as the initial position, meaning that the bStopIpo is active until the axis are in X0 Y0 and the release the interpolator to set the new positions to X500 Y500. Is there a suggested method to solve this behavior? bonus question: I get a lot of bStopIpo during standard interpolation movements (not gaps). While working with virtual axis this is not a problem but when real axis are installed this will be an issue. What exactly triggers the bStopIpo output? Slow axis accelerations compare to Gcode defaults? Kind Regards
Last updated: 2024-02-05

Post by anlebr on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi I am trying use the Codesys Communication Manager to set up an Opc ua server with a custom information model. As a start I am using the Boiler model available on Opc foundations github page. I am testing with a Wago CC100 and using Codesys V3.5 SP19 Patch 6. I get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://opcfoundation.org/UA/Boiler/ with a minimal publication date from 15/12/2023 but the device has only a model from 15/09/2021 installed. Probably the information model from 15/09/2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway, both versions are available in the repository. How can I solve this?
Last updated: 2024-03-13

Post by squiggleypuff on RemoteTargetVisu creates Unresolved Reference CODESYS Forge talk (Post)
I have a project with a Festo CPX-E-CEC-C1-PN PLC (Run-time version 3.5.12.50) that I have been developing on just fine using Codesys V3.5 SP19 Patch 5 (64bit). I am at the stage where I wanted to use the Festo HMI screen, and have added a RemoteTargetVisu object to my application. After adding this object, I am no longer able to log in to the PLC as I get an Unresolved Reference warning for 'USERMGRUSERGETPROPERTY' towards the end of the download process. I was able to find this post (https://forge.codesys.com/forge/talk/Visualization/thread/fc686a6cb2/) where the two possible solutions are to "set the placeholder to emtpy" or update the runtime. Problem is, I don't know how to do either of these things, as I'm still very green in Codesys land. I'd be happy to update the Festo PLC runtime, as that seems like the better option, but have not had any luck in finding a tutorial for this online. If anyone could point me in the right direction I'd appreciate it.
Last updated: 2024-03-19

Post by jrsantab on Remote connection to ifm PLC & HMI CODESYS Forge talk (Post)
We have finally solved the problem. The version of the Gateway in the computer that worked (3.5.11.0) and the one that didn't (3.5.17.30) was different. We have three different Codesys 3.5 versions installed because we work with different controllers. I believe that, depending on the sequence you follow to install the versions you get a different Gateway version. To solve the problem you first have to disable the "obsolete" services. Open services, serach for (in our case) CODESYS Gateway V3 Version 3.5.11.0 CODESYS ServiceControl Version 3.5.11.0 I stopped the services and changed to Manual Start. Then you have to create the new services. In our case, from a Command Prompt session (cmd): SC CREATE "Codesys GatewayService Rigual" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\GatewayService.exe" and then SC CREATE "CODESYS ServiceControl Version 3.5.17.30" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\CODESYSControlService.exe" remember also to set them as Automatic Start!
Last updated: 2024-04-22

Post by caprez95 on Trace Restart Visuelement CODESYS Forge talk (Post)
Hallo zusammen. Ich habe schon länger mit dem Problem zu kämpfen, dass ich einen Trend (Visuelement) nicht resetten (neustarten) kann. Ich habe es jetzt mit dem Beispiel hinbekommen, die Trace-Aufzeichnung über die CmpTraceMgr Bibliothek zu steuern. Aber wie bekomme ich diese Trace-Aufzeichnung in ein Visuelement? Der Code sieht wie folgt aus: // Configure trace IF xInit THEN // Create a trace packet PacketConfig.pszName := ADR('IECTraceConfiguration.Trace1'); // Name of trace PacketConfig.pszApplicationName := ADR('IECTraceConfiguration'); // Name of the application PacketConfig.pszIecTaskName := ADR('Task'); // Name of the task PacketConfig.pszComment := ADR('Demo packet'); PacketConfig.ulEveryNCycles := 1; PacketConfig.ulBufferEntries := 1000; PacketConfig.ulFlags := TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_TIMESTAMP_MS AND TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_AUTOSTART; IF (NOT fbTraceManager.CreatePacket(PacketConfig := PacketConfig, hPacket=>hPacket1)) THEN xError := TRUE; END_IF // Create a trace record RecordConfig.pszVariable := ADR('iSignal'); // This is the name of variable to record RecordConfig.tcClass := INT_TO_UDINT(TypeClass.TYPE_INT); // Type of the recording variable RecordConfig.ulSize := SIZEOF(iSignal); // Size of the recording variable pApp := AppFindApplicationByName('IECTraceConfiguration', 0); AppGetAreaOffsetByAddress(pApp, ADR(iSignal), ADR(RecordConfig.tvaAddress.taAddress.Area.usArea), ADR(RecordConfig.tvaAddress.taAddress.Area.ulOffset)); // Get and set area offsets RecordConfig.tvaAddress.ulAddressFlags := TRACE_VAR_ADDRESS_FLAGS_IEC OR TRACE_VAR_ADDRESS_FLAGS_AREA_OFFSET; RecordConfig.ulGraphColor := 16#FF00FF00; // green RecordConfig.ulGraphType := 1; // Line with points IF (NOT fbTraceManager.AddRecord(RecordConfig := RecordConfig, hPacket := hPacket1, hRecord => hRecord1)) THEN xError := TRUE; END_IF xInit := FALSE; END_IF // Starts the recording IF xStart THEN IF (NOT fbTraceManager.StartPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStart := FALSE; END_IF // Stop the recording IF xStop THEN IF (NOT fbTraceManager.StopPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStop := FALSE; END_IF // Reset the recording IF xReset THEN IF (NOT fbTraceManager.ResetPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xReset := FALSE; END_IF
Last updated: 2024-06-04

Post by roundex on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
I got same issue but managed to get it to work again by downgrading the Runtime. Here's my specs: CODESYS V3.5.19.0 Runtime Linux SL 4.7.0.0. CSV Utility SL 1.1.0.0 (Licensed IIoT libraries SL) I tried Runtime 4.8.0.0. and 4.9.0.0 but both result in INVALID_HANDLE error.
Last updated: 2023-08-30

Post by transmin01 on CANbus issue CODESYS Forge talk (Post)
Hi, I have been trying to get a CANbus device working with Codesys 3.5SP19 patch1 via a Beckhoff EL6751 gateway without success. I have the CANOpen_Manager and CANopen device configured but this will not run. Is there any code required to kickstart the CANbus comms into action? Regards Trevor
Last updated: 2023-09-13