Search talk: COPY ONE ARRAY TO ANOTHER

 
<< < 1 .. 209 210 211 212 213 .. 222 > >> (Page 211 of 222)

Post by cebador on trouble with running a python script on Raspberry via Codesys CODESYS Forge talk (Post)
Hello, I am new to Codesys and I'm having trouble with running a python script on my Raspberry. SysProcessExecuteCommand2 gives result 25 and nothing happens. I used chmod +x and chmod 666 on my script. In terminal it's working when I'm using the same command line as in Codesys. Code in attatched screenshot. Thank You in advance.
Last updated: 2025-07-23

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Thanks once again. Right now the codesys virtual control sl docker is using the host ip itself not the docker ip. so the local host edge gateway was able to search the virtual plc. so you are telling me instead of local host edge gateway I should use the edge gateway docker version?
Last updated: 2025-08-08

Post by astrum on OPC UA Information Model Error "Dimensions must be empty" CODESYS Forge talk (Post)
Hello everyone, does anyone know what this error means: Internal Error in code generation for http://opcfoundation.org/UA/DI/: Dimensions must be empty. I use the standard information models from Codesys and haven't even called the Information Model, but my program can't compile. the only thing I did was to insert the Communication Manage.
Last updated: 2025-08-11

Post by wagokurt on TargetVisu option missing in IDE CODESYS Forge talk (Post)
I have installed both the Codesys Control for Linux SL 4.16.0.0 and Target Visu for Linux 4.16.0.0 packages in Codesys 3.5 SP21 Patch2. When I try to add a target visu, it is missing. I have spent hours on this and tried different machines, all behave the same way. Is this a bug?
Last updated: 2025-08-21

Post by morecoffee on Control for Raspberry Pi 4.17 CODESYS Forge talk (Post)
I am currently having the issue that Codesyscontrol only runs for 10 seconds on my Raspberry Pi 4. I believe the problem is because the MAC address range is of the Raspberry is 88:A2:9E:XX:XX:XX. When will Codesys Control For Raspberry Pi 4.17.0.0 be released to fix this issue?
Last updated: 2025-08-22

Post by nilanjan on I want to show the current recipe name in the visualization screen CODESYS Forge talk (Post)
I am having some trouble showing the current recipe name in visualization i am not using the RecipeManCommands i am using the inbuild visualization feature of Saving and Loading recipes. I need it so the user would have a track on which recipe is being used currently.
Last updated: 2025-08-24

Post by eksheep on Unit Tests and C007: Unknown Type CODESYS Forge talk (Post)
Hello, I am attempting to implement unit tests for my POUs. When building and running the unit tests I receive error C007: Unknown Type for all types defined in the library, Standard, 3.5.18.0. Which is included in the POU Library Manager. Any input would be appreciated. TIA.
Last updated: 2025-08-27

Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
Thank you very much for the quick answer! The RPi hw were delivered last week so it's probably a resent version. I found an old scrapped board (2 years or so) with a broken GPIO that I tested with the same SD card image and with that board Codeys can run for the full 2h demo period without issues. Then I went back the the new board to test the 4.17.0.0 release but the installation fails... [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol Do you have any idea what could be the reason? I'm using an OS image including Python drivers for LCD and some I/O:s from last year to keep things stable, but also after upgrading with sudo apt update && sudo apt upgrade I still get the same error Reverting back to 4.15.00 works fine: [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesysedge started [INFORMATION] Successfully installed codesyscontrol [INFORMATION] Successfully started CODESYS Edge Gateway for Linux [INFORMATION] Successfully started CODESYS Control for Raspberry Pi SL but as before the Codesys services stops after 30 seconds. And I noticed that the Codesys control stops and is not reachable also if I have no application loaded.
Last updated: 2025-09-02

Post by alexgooi on Execute a .py file with Codesys CODESYS Forge talk (Post)
Hello yann, In the past I have experimented with the execution of Linux commands using Codesys. Maybe this article helps: https://www.linkedin.com/pulse/run-linux-commands-from-codesys-jouke-aalvanger When you are able to execute Linux commands in Codesys, you can run the Python script.
Last updated: 2025-09-03

Post by gseidel on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic CODESYS Forge talk (Post)
Hi imdatatas, thanks for your feedback. This change was intentional, as the quadratic ramp type has many advantages over the trapez ramptype. Sorry to hear it causes problems in your situation. Can you please shortly explain the nature of the problems? Best regards, Georg
Last updated: 2025-09-08

Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC CODESYS Forge talk (Post)
Thank you Pernockham, I am using Windows SoftPLC and the device is CODESYS Control Win V3 x64. In the above attached example, the file is Linux-based. This is an external add-on file in the CODESYS installer (CODESYS Control for PLCnext SL). I am trying to implement it without this add-on file.
Last updated: 2025-09-09

Post by kio123 on SysFileOpen not working CODESYS Forge talk (Post)
I have exactly the same problem and tried entering “ForceIecFilePath=0” in the file “CODESYSControl.cfg” ([SysFile]). Unfortunately, this was unsuccessful. Can anyone help in the meantime, e.g., with some sample code or with the FAQ that TimvH refers to above (link no longer works)? Many thanks and best regards
Last updated: 2025-09-15

Post by totorovic on Project loses 'Download time' information CODESYS Forge talk (Post)
Hello, Today I have the problem again. The code in my IDE is the same as the code in the runtime but I cannot Log in to the PLC without download. Juste because the Download information is 'None'. And I don"t know how is managed this information bu Codesys. I'M WAITING SINCE 17 MONTHS, CAN I PLEASE HAVE A ANSWER FROM CODESYS?
Last updated: 2025-09-18

Post by imdatatas on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic CODESYS Forge talk (Post)
Dear @gseidel, Thank you for your clarification. I fully agree that the quadratic ramp type may have certain technical advantages. However, the main problem is backward compatibility and consistency across projects. In many automation projects, application developers rely on the fact that creating a new axis object will behave exactly the same way as in previous versions. With SoftMotion V4.18.0.0 and later, if an application developer adds an axis and overlooks the changed default, the motion function blocks behave differently than expected. In particular, since the Jerk value in SM3_Basic function blocks is ineffective in trapezoid ramp type, users are accustomed to leaving this parameter empty in their projects. In many existing projects, this variable has not even been assigned. When the default is changed to quadratic, the Jerk parameter suddenly becomes relevant, which can cause errors or unexpected behaviour in the field. From a user perspective, a default setting should always be the “safe” and “expected” option, while alternative options (like quadratic) can be selected manually if desired. Keeping the default as trapezoid ensures compatibility with existing projects and prevents unexpected issues, while still allowing users to benefit from quadratic ramps if they explicitly choose so. For these reasons, I kindly ask you to reconsider making trapezoid the default again. This would significantly reduce the risk of unexpected behaviour in future projects while still preserving the advantages of the quadratic ramp type for those who actively select it. Of course, the final decision is entirely at your discretion. Best Regards, imdatatas
Last updated: 2025-09-26

Post by jy77812 on Visualization XY Charter Question CODESYS Forge talk (Post)
Hello. I'm using Visualization XY Chart, and when I mark a circle through XY position data, a blue line is displayed in the circle with a red circle. At this time, can't I set the blue line not to be seen in the circle? Currently, whenever XY position is drawn, the line follows.
Last updated: 2025-10-02

Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20? CODESYS Forge talk (Post)
Hi, I’m evaluating CODESYS for our devices. If I buy a standard runtime and the Toolkit, can I create a custom device descriptor so users can select my device (instead of just “CODESYS Control for Linux ARM64 SL”) when starting a new project? Has anyone done this or know if it’s possible? Thanks!
Last updated: 2025-10-07

Post by ulad on SPI Communication CODESYS Forge talk (Post)
Hello. I created a project that uses SPI. This project is working well. I can see with an oscilloscope that the SPI pins are actually changing. But when I resave this project in the IDE and open it later in the system, I see a constant error. What do I need to fix? What am I doing wrong? Thank you.
Last updated: 2023-12-23

Post by svn123 on In Simulation Mode, logic is not executing CODESYS Forge talk (Post)
I stopped the simulation and tried to rebuild. "Cloned Task0.task0. Priority already in use" error was shown after rebuilding. I used Build-Clean All option and rebuilt again. Now the logic started working. But I am not still sure what caused the error in first place. If somebody knows about this error, please enlighten me. Thanks svn
Last updated: 2023-12-25

Post by anderson on function block output CODESYS Forge talk (Post)
so it is not possible for me to use the function blocks and through them I can select the digital outputs of the PLC so that pulses and direction are output, or some function block that does this reading and in it I can program the pulse and direction outputs for the drive?
Last updated: 2024-01-09

Post by oscardm on Problem install codesys 3.5.17 SP 30 with Codesys Installer CODESYS Forge talk (Post)
Hi, I have a problem with codesys installer: if install a package on the codesys 3.5.17 SP17, and i try to install a package, for example SVN package, the codesys installer report the "digital signature expired error". Anyone have an idea for resolution ? Thanks for your feedback
Last updated: 2024-01-12

Post by hfelek on *SOURCEPOSITION* App = [Application] area=0, offset = 0 on default example CODESYS Forge talk (Post)
Hello, I am trying to run CmpTemplate component provided by Codesys for version 3.5.17. I call MyExternalFunction from the component but I get error as shown below. I see component is loaded successfully on runtime logs. I feel like I am missing something basically.
Last updated: 2024-01-15

Post by fcmtw on SDO generation CODESYS Forge talk (Post)
Hi, When I'm adding a CANOpen device in my WAGO CANOpen Manager, CODESYS automaticaly generates some SDO's that I can't directly disable. From what those SDO's are generated ? I'm not finding anything about it in the EDS files. Also, is there a way to disable the automaticaly generated SDO and execute the manualy created ones ? Regards, Florian
Last updated: 2024-01-23

Post by rkohser on Python Script for Finding "Last saved with" Value CODESYS Forge talk (Post)
Hi jkilburn, I have the exact same issue and thought I would search a solution on this forum. I see you did not get any answer, did you find a solution on how to extract the last saved version of codesys from the project file ? Roland
Last updated: 2024-01-29

Post by nano on Modbus TCP/IP slave communication errow CODESYS Forge talk (Post)
please tell us the exact error message from diagnostic. U can view it at devicetree in the node-element diagnostic from modbus-configuration. u also can activate the function auto-reconnect in master and increase a little bit the timeout and the repetition to male thw communication a little bit more robust
Last updated: 2024-02-04

Post by ronaldcom-pac on Gif in WebVisu CODESYS Forge talk (Post)
I am looking for some help with using Gifs in the WebVisu of codesys 3.5.18.40 as the model we tried with ladder logic does not animate the Gif and leaves as the first image of the Gif. Is there a way for ST or LL for it to be animated?
Last updated: 2024-02-08

<< < 1 .. 209 210 211 212 213 .. 222 > >> (Page 211 of 222)

Showing results of 5527