AC Persistence - values are not read from file during start?
CODESYS Forge
talk
(Thread)
AC Persistence - values are not read from file during start?
Last updated: 2025-09-03
Webvisu Combined Authentication
CODESYS Forge
talk
(Thread)
Webvisu Combined Authentication
Last updated: 2025-09-03
Post by gunstr on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
I now tried to install 4.17.0.0 on a fully clean installations: A brand new RPi 4B Install latest Raspberry Pi OS Lite, Release date 13 May 2025, 64bit run sudo apt update && sudo apt full-upgrade When asked - Select to install the updated version of '/etc/initramfs-tools/initramfs.conf' Install CODESYS Control for Raspberry Pi SL. version 4.17.0.0 Log output: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.0.197) [WARNING] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [WARNING] Error detecting container architecture [INFORMATION] Finished reading device information [ERROR] Error output: /var/lib/dpkg/info/codesyscontrol.postinst: 88: check_legacy_extensionapi_folder: not found [INFORMATION] Standard output: Selecting previously unselected package codesyscontrol. [INFORMATION] Standard output: (Reading database ... 76772 files and directories currently installed.) [INFORMATION] Standard output: Preparing to unpack .../codesyscontrol_raspberry_4.17.0.0_all.deb ... [INFORMATION] Standard output: Unpacking codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: Setting up codesyscontrol (4.17.0.0) ... [INFORMATION] Standard output: make config rw [INFORMATION] Standard output: set folder permissions [INFORMATION] Standard output: prepare permissions [INFORMATION] Standard output: check legacy extension api folder [INFORMATION] Standard output: create and install daemon [INFORMATION] Standard output: codesyscontrol started [WARNING] Unable to detect Raspberry Pi Architecture. Setting armv6l as default, you can change this through the settings panel. [INFORMATION] Standard output: codesyscontrol stopped [ERROR] Expected exit value of command failed: expected 0, received 1 [WARNING] Error setting the Raspberry Pi Architecture [ERROR] Error installing codesyscontrol If I read the log correctly the control is actually installed but cannot start. I'm running out of ideas how to proceeed now, any suggestions are welcome.
Last updated: 2025-09-03
Virtual Runtime CSV Utility Error
CODESYS Forge
talk
(Thread)
Virtual Runtime CSV Utility Error
Last updated: 2025-09-03
Post by leandroct on Creating Boot Application not working
CODESYS Forge
talk
(Post)
I have a Control Win V3.5 SP20 (64-bit) application, and until now, I open the program (with a password) and download it. However, I need to give the client the option to install the program on the Controller, without them having to open it and access the code. So, I followed these steps: 1 – In the Online => Create Boot Application menu, I saved the generated files in a directory: Application.app Application.crc PlcLogic\visu\ directory with several files 2 – In the SysTray, I ran the PLC, and it created a directory. In the root of this directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E84889DB), I pasted Application.app and Application.crc. Since it created a \visu directory, I pasted the PlcLogic\visu\ files generated in Create Boot Application into it. 3 - In the general Codesys directory (C:\ProgramData\CODESYS\CODESYSControlWinV3x64), I edited CodesysControl.cfg, adding: [CmpLog] Application.1=Application 4 - When running the PLC, nothing happens and the TargetVisu screen does not open. What I'm doing wrong?
Last updated: 2025-09-03
Post by taywinkel on Virtual Runtime CSV Utility Error
CODESYS Forge
talk
(Post)
Hello, I am having trouble figuring out the proper location for my virtual runtime to create a .CSV file. No matter the file location I set, I get error 14 (CANNOT_OPEN_DIRECTORY). I have tried multiple different file paths ('/', '/var/opt/codesysvcontrol/PlcLogic', '/var/opt/codesys/'). I understand that there is only certain places that Codesys can read/write. I am also running this virtual runtime in a Podman container. Does anyone know what the location should be? I attached the archive I was using, a project that tests CSV capability that I borrowed from someone else. Thanks!
Last updated: 2025-09-03
Post by eschwellinger on CODESYS control on RPi starts, shortly runs, then exits
CODESYS Forge
talk
(Post)
let me check - had a similar case today
Last updated: 2025-09-03
Streamlining Mental Health Services Through Virtual Assistance
CODESYS Forge
talk
(Thread)
Streamlining Mental Health Services Through Virtual Assistance
Last updated: 2025-09-03
Medical Billing Time Limits in California and Washington Explained
CODESYS Forge
talk
(Thread)
Medical Billing Time Limits in California and Washington Explained
Last updated: 2025-09-03
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
Trying to communicate (from Europe) with/to a unit located in china, the communication seems blocked/stopped. The edge gateway is installed in a linux environment and was possible to link to my Automation server account using the "Automation service tool". However it seems the unit cannot communicate with the Automation server (a Network scan will give the message "Gateway not connected"). (I have tested the eq. setup with units locally which works.) Anyone having experience situation similar to this and if its possible to make this work? Will a VPN be needed possibly? Other tips?
Last updated: 2025-09-04
Post by chloereed on Creating Boot Application not working
CODESYS Forge
talk
(Post)
Last updated: 2025-09-04
Post by imdatatas on The default ramp type selection in SoftMotion V4.18.0.0 is Quadratic
CODESYS Forge
talk
(Post)
Unfortunately, The same behaviour still exist with SoftMotion V4.19.0.0 too. (default ramp type is quadratic instead trapezoid for new created axis object) For your information.
Last updated: 2025-09-04
Post by leandroct on Creating Boot Application not working
CODESYS Forge
talk
(Post)
I did these steps and it worked: - Copied Application.app and Application.crc to the Folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\ID_of_CPU\PlcLogic\Application\ copied the visu folder content to the folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\ID_of_CPU\PlcLogic\Application\visu\ Changed by Notepad the CODESYSControl.cfg at the folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\ID_ of_CPU\ Where is [CmpApp], adding a line with: Application.1=Application
Last updated: 2025-09-04
Application-based license Modbus Channels
CODESYS Forge
talk
(Thread)
Application-based license Modbus Channels
Last updated: 2025-09-04
Post by gmau on Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired
CODESYS Forge
talk
(Post)
Hello, I am writing to You with the problem of Profinet communication in my Codesys V2.5 SP21 project working on Codesys Control RTE V3 x64 device. I have implemented multiple Profinet devices in the network, the Profinet itself is configured properly, based on the hardware and software parameters of the industrial PC (Windows 10 IoT). My Profinet network contains such Profinet devices as a robot, IO-Link master with some devices on it, IO modules, safety, vision sensor (the configuration is attached to this topic). Once every few hours, sometimes more often, sometimes not even once a day, the error show up at one, two or a few random modules at the same time, every one is the same: "Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired". The communication is then lost with that module, but it is up instantly. It is not such a problem when it comes to regular IOs, but with safety or rotation table, it causes errors and machine stops. I have tried multiple solution based on any forum suggestions, manuals, etc., but it is still happening. Mabye when I turned on the Watchdog for this communication, it is happening less times, but still, I could not turning up the Watchdog parameters at the expense of cycle time of the process. The same is with Send Clock, Reduction and DHT. I have one of the ethernet port on the PC configured with CmpEt1000Drv driver. The card itself is Intel Ethernet Connection I219-LM. These devices are connected to one EKI-2728-NI-A Profinet switch (it was changed from the standard non Profinet one, but still nothing has changed). As I said ealier, I am attaching all the configurations for each device and the communication itself - if any of You had the same problems or have any ideas what could be the cause, I would be much gratefull for any help. For now I am out of ideas, if You have any additional question, please ask. Sincerely, PF
Last updated: 2025-09-04
Post by timvh on Codesys virtual control redundancy
CODESYS Forge
talk
(Post)
I think it depends on what you consider as redundant. Is it allowed to plug the network cable in another device (server), move the USB key with license to the other device (server) and then start it up? Or should it automatically switch over within msec and take over the communication with the I/O flawlessly without noticing the switchover? We helped several customers setting up the CODESYS Redundancy functionality and the nice thing is that when you have it up and running, you can easily switchover from active to passive and when you download a new applicaiton, CODESYS handles the update of boot project on the passive controller automatically. Sure this will require an additional license and the license for redundancy, but if your installation is that critical it should be worth it. Please contact us (Extend Smart Coding) if you need any further information. We could help you setup the configuration and possibly provide the licenses for it (I noticed you are situated in the Netherlands).
Last updated: 2025-09-04
Post by timvh on I want to show the current recipe name in the visualization screen
CODESYS Forge
talk
(Post)
Maybe the easiest solution for you is to add one STRING variable to your recipe and enter the name of the recipe in variable value. This is little bit double the work (naming the recipe and entering the value of the STRING variable), but in that case you always have the current value of the variable which you can read from the application and show in the visualization.
Last updated: 2025-09-04
Codesys virtual control redundancy
CODESYS Forge
talk
(Thread)
Codesys virtual control redundancy
Last updated: 2025-09-04
Post by sandro66 on Application-based license Modbus Channels
CODESYS Forge
talk
(Post)
Hi Gatto, Using version 3.5.21.xx, it is no longer possible to use Modbus function blocks (I make extensive use of these FBs.)as shown in the example. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_modbus_example.html The compiler detects one Modbus instance for each instance of the communication FB block. The example program above, although simple, reports 8 Modbus instances when compiled with the latest version. Codesys Support says that you must use fieldbus I/O mapping, but this will result in the loss of the ability to programmatically modify communication parameters. Sandro
Last updated: 2025-09-04
Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired
CODESYS Forge
talk
(Thread)
Station 'xyz': AR aborted by device (alarm.ind): AR consumer DHT expired
Last updated: 2025-09-04
Post by onstage on Unable to add EL6751 to Control RTE V3 on W11 IoT LTSC using Eng. V3.5 SP21
CODESYS Forge
talk
(Post)
I have working EtherCAT since it can be scanned for slaves, but then I'm stuck getting the information that the device isn't found in the repo. As far as I can see both revisions does however exist in the device repo. Component added in the Configfile. Anyone with some similar experiences?
Last updated: 2025-09-04
Post by zatalian on password policy
CODESYS Forge
talk
(Post)
Is there a way to not enforce password policy or change the rules for this policy? Device is a Codesys Control for Raspberry Pi 4.17.
Last updated: 2025-09-05
Post by voffi on projects.open not working for file based storage project
CODESYS Forge
talk
(Post)
Hello! Opening a project from a python script given at the CODESYS command line does not work for me with a file based storage project. Example: Running projects.open("test.project", primary = True) works but converting the project to a file based storage project and then give the folder name as an argument to project.open Running projects.open("test.fbsproj", primary = True) does not work. We decided to work with file based storage for the project. Is there a scripting API for file-based storage to e.g. convert it while running the script back or how to open file based storage project with projects.open? Thank you! voffi
Last updated: 2025-09-05
projects.open not working for file based storage project
CODESYS Forge
talk
(Thread)
projects.open not working for file based storage project
Last updated: 2025-09-05
Post by cmason on v3.5 SP19 - Modbus TCP Devices - Channel Limit?
CODESYS Forge
talk
(Post)
There still is no solution to this. I am running Modbus version 4.4.0.0 and it still wont let me add more than 10 channels. Does anyone have a solution for this?
Last updated: 2025-09-05
To search for an exact phrase, put it in quotes. Example: "getting started docs"